Extended imaging volume in cone-beam x-ray tomography using the weighted simultaneous iterative reconstruction technique

被引:8
|
作者
Sanctorum, Joaquim G. [1 ]
Van Wassenbergh, Sam [2 ]
Van Nguyen [3 ]
De Beenhouwer, Jan [3 ]
Sijbers, Jan [3 ]
Dirckx, Joris J. J. [1 ]
机构
[1] Univ Antwerp, Lab Biophys & Biomed Phys BIMEF, Antwerp, Belgium
[2] Univ Antwerp, Lab Funct Morphol FunMorph, Antwerp, Belgium
[3] Univ Antwerp, Imec Vis Lab, Antwerp, Belgium
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 16期
关键词
x-ray tomography; detector offset; field-of-view; image intensifier; cone-beam; SIRT; CT;
D O I
10.1088/1361-6560/ac16bc
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An issue in computerized x-ray tomography is the limited size of available detectors relative to objects of interest. A solution was provided in the past two decades by positioning the detector in a lateral offset position, increasing the effective field of view (FOV) and thus the diameter of the reconstructed volume. However, this introduced artifacts in the obtained reconstructions, caused by projection truncation and data redundancy. These issues can be addressed by incorporating an additional data weighting step in the reconstruction algorithms, known as redundancy weighting. In this work, we present an implementation of redundancy weighting in the widely-used simultaneous iterative reconstruction technique (SIRT), yielding the weighted SIRT (W-SIRT) method. The new technique is validated using geometric phantoms and a rabbit specimen, by performing both simulation studies as well as physical experiments. The experiments are carried out in a highly flexible stereoscopic x-ray system equipped with x-ray image intensifiers (XRIIs). The simulations showed that higher values of contrast-to-noise ratio could be obtained using the W-SIRT approach as compared to a weighted implementation of the simultaneous algebraic reconstruction technique (SART). The convergence rate of the W-SIRT was accelerated by including a relaxation parameter in the W-SIRT algorithm, creating the aW-SIRT algorithm. This allowed to obtain the same results as the W-SIRT algorithm, but at half the number of iterations, yielding a much shorter computation time. The aW-SIRT algorithm has proven to perform well for both large as well as small regions of overlap, outperforming the pre-convolutional Feldkamp-David-Kress algorithm for small overlap regions (or large detector offsets). The experiments confirmed the results of the simulations. Using the aW-SIRT algorithm, the effective FOV was increased by >75%, only limited by experimental constraints. Although an XRII is used in this work, the method readily applies to flat-panel detectors as well.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Evaluation of an iterative algorithm for three dimensional x-ray cone beam reconstruction
    Donaire, JG
    Roca, J
    Garcia, I
    INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, PROCEEDINGS - VOL III, 1996, : 575 - 578
  • [42] Iterative volume of interest image reconstruction in helical cone beam X-Ray CT using a stored system matrix approach
    Xu, Jingyan
    Tsui, Benjamin M. W.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [43] Verifying Cone-Beam CT Extended Axial Coverage with Iterative Reconstruction Using Real Data
    Davis, Andrew M.
    Pearson, Erik A.
    Pelizzari, Charles A.
    Pan, Xiaochuan
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [44] Performance evaluation of the simplified spherical harmonics approximation for cone-beam X-ray luminescence computed tomography imaging
    Zhang, Haibo
    Geng, Guohua
    Chen, Yanrong
    Zhao, Fengjun
    Hou, Yuqing
    Yi, Huangjian
    Zhang, Shunli
    Yu, Jingjing
    He, Xiaowei
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2017, 10 (03)
  • [45] Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography)
    Siewerdsen, JH
    Jaffray, DA
    MEDICAL PHYSICS, 2000, 27 (08) : 1903 - 1914
  • [46] Virtual alignment of x-ray cone-beam tomography system using two calibration aperture measurements
    Bronnikov, AV
    OPTICAL ENGINEERING, 1999, 38 (02) : 381 - 386
  • [47] An In-House Cone-Beam Tomographic Reconstruction Package for Laboratory X-ray Phase-Contrast Imaging
    Hofmann, Juergen
    Zboray, Robert
    APPLIED SCIENCES-BASEL, 2022, 12 (03):
  • [48] Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy
    Paul, Jijo
    Jacobi, Volkmar
    Farhang, Mohammad
    Bazrafshan, Babak
    Vogl, Thomas J.
    Mbalisike, Emmanuel C.
    EUROPEAN RADIOLOGY, 2013, 23 (06) : 1582 - 1593
  • [49] Radiation dose and image quality of X-ray volume imaging systems: cone-beam computed tomography, digital subtraction angiography and digital fluoroscopy
    Jijo Paul
    Volkmar Jacobi
    Mohammad Farhang
    Babak Bazrafshan
    Thomas J. Vogl
    Emmanuel C. Mbalisike
    European Radiology, 2013, 23 : 1582 - 1593
  • [50] Laboratory Cone-Beam X-Ray MicroCT System
    Krivonosov, Yu. S.
    Buzmakov, A. V.
    Grigorev, M. Y.
    Rusakov, A. A.
    Dymshits, Yu. M.
    Asadchikov, V. E.
    CRYSTALLOGRAPHY REPORTS, 2022, 67 (07) : 1292 - 1297