Iterative volume of interest image reconstruction in helical cone beam X-Ray CT using a stored system matrix approach

被引:0
|
作者
Xu, Jingyan [1 ]
Tsui, Benjamin M. W. [1 ]
机构
[1] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21218 USA
关键词
iterative image reconstruction; helical cone beam computed tomography; dose reduction; CT artifacts reduction; TOMOGRAPHY; PROJECTION;
D O I
10.1117/12.878914
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present an efficient scheme for the forward and backward projector implementation for helical cone-beam x-ray CT reconstruction using a pre-calculated and stored system matrix approach. Because of the symmetry of a helical source trajectory, it is sufficient to calculate and store the system matrix entries for one image slice only and for all source positions illuminating it. The system matrix entries for other image slices are copies of those stored values. In implementing an iterative image reconstruction method, the internal 3D image volume can be based on a non-Cartesian grid so that no system matrix interpolation is needed for the repeated forward and backward projection calculation. Using the proposed scheme, the memory requirement for the reconstruction of a full field-of-view of clinical scanners is manageable on current computing platforms. The same storage principle can be generalized and applied to iterative volume-of-interest image reconstruction for helical cone-beam CT. We demonstrate by both computer simulations and clinical patient data the speed and image quality of VOI image reconstruction using the proposed stored system matrix approach. We believe the proposed method may contribute to bringing iterative reconstruction to the clinical practice.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Iterative image reconstruction in helical cone-beam x-ray CT using a stored system matrix approach
    Xu, Jingyan
    Tsui, Benjamin M. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11): : 3477 - 3497
  • [2] System matrix analysis for sparse-view iterative image reconstruction in X-ray CT
    Wang, Linyuan
    Zhang, Hanming
    Cai, Ailong
    Li, Yongli
    Yan, Bin
    Li, Lei
    Hu, Guoen
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2015, 23 (01) : 1 - 10
  • [3] Improving iterative image reconstruction for X-ray CT
    Dinis Almeida, Pedro Miguel
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (08) : 1062 - 1062
  • [4] Sparse Angular X-ray Cone Beam CT Image Iterative Reconstruction Using Normal-dose Scan Induced Nonlocal Prior
    Zhang, Hua
    Bian, Zhaoying
    Ma, Jianhua
    Huang, Jing
    Gao, Yang
    Liang, Zhengrong
    Chen, Wufan
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3671 - 3674
  • [5] Extended imaging volume in cone-beam x-ray tomography using the weighted simultaneous iterative reconstruction technique
    Sanctorum, Joaquim G.
    Van Wassenbergh, Sam
    Van Nguyen
    De Beenhouwer, Jan
    Sijbers, Jan
    Dirckx, Joris J. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (16):
  • [6] Image representation using mollified pixels for iterative reconstruction in x-ray CT
    Noo, F.
    Schmitt, K.
    Stierstorfer, K.
    Schoendube, H.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 3453 - 3455
  • [7] VOLUME OF INTEREST MEGAVOLTAGE CONE-BEAM CT WITH A LOW ATOMIC NUMBER X-RAY TARGET
    Robar, J.
    Berman, A.
    MacDonald, A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S48 - S48
  • [8] Matrix Approach for Processing of Iterative Reconstruction on Cone Beam
    Chen Jian-lin
    Zhang Han-ming
    Yan Bin
    Li Lei
    Guan Ming
    Wang Lin-yuan
    PROCEEDINGS OF 2013 IEEE INTERNATIONAL CONFERENCE ON MEDICAL IMAGING PHYSICS AND ENGINEERING (ICMIPE), 2013, : 72 - 77
  • [9] Assessment of Absorbed Dose and Image Quality Using Cone Beam CT On An X-Ray Angiography System
    Supanich, M.
    Vanderhoek, M.
    MEDICAL PHYSICS, 2013, 40 (06)