Sparse Angular X-ray Cone Beam CT Image Iterative Reconstruction Using Normal-dose Scan Induced Nonlocal Prior

被引:0
|
作者
Zhang, Hua [1 ]
Bian, Zhaoying [1 ]
Ma, Jianhua [1 ]
Huang, Jing [1 ]
Gao, Yang [1 ]
Liang, Zhengrong [2 ]
Chen, Wufan [1 ]
机构
[1] Southern Med Univ, Sch Biomed Engn, Guangzhou 510, Guangdong, Peoples R China
[2] SUNY Stony Brook, Radiat Dept, Stony Brook, NY 11794 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Repeated X-ray cone beam computed tomography (CBCT) scans are frequently entailed in some clinical cases, such as CT-guided lung lesions puncture examination, image-guided intervention and radiotherapy, which result in individual patient doses soaring due to the associative volume scanning. Sparse-views based image reconstruction, as an effective method for reducing the radiation dose in CBCT scans, has been extensively studied recently. Due to the huge anatomical information similarity of images from repeated scans, if given a full-views scan, the associative reconstructed images can be used as important priori information for image reconstruction from sparse-views data. With above observation, in this paper, we propose a normal-dose scan induced nonlocal prior (ndiNLM-Prior) for yielding accurate image from the sparse-views data with an iterative image reconstruction process. The present ndiNLM-prior can exploit the similar information from the images reconstructed from the full-views data without needing accurate image registration. Evaluations with the physical and digital phantom data clearly demonstrate that the presented method achieves higher image reconstruction accuracy in terms of streak artifacts suppression.
引用
收藏
页码:3671 / 3674
页数:4
相关论文
共 50 条
  • [1] Iterative Image Reconstruction for Sparse-View CT Using Normal-Dose Image Induced Total Variation Prior
    Huang, Jing
    Zhang, Yunwan
    Ma, Jianhua
    Zeng, Dong
    Bian, Zhaoying
    Niu, Shanzhou
    Feng, Qianjin
    Liang, Zhengrong
    Chen, Wufan
    PLOS ONE, 2013, 8 (11):
  • [2] Iterative image reconstruction for sparse-view CT using normal-dose image induced total variation prior
    Zhang, Yunwan
    Ma, Jianhua
    Huang, Jing
    Zhang, Hua
    Bian, Zhaoying
    Zeng, Dong
    Feng, Qianjin
    Liang, Zhengrong
    Chen, Wufan
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [3] Iterative Reconstruction for X-Ray Computed Tomography Using Prior-Image Induced Nonlocal Regularization
    Zhang, Hua
    Huang, Jing
    Ma, Jianhua
    Bian, Zhaoying
    Feng, Qianjin
    Lu, Hongbing
    Liang, Zhengrong
    Chen, Wufan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (09) : 2367 - 2378
  • [4] ITERATIVE IMAGE RECONSTRUCTION FOR LOW-DOSE X-RAY CT USING A SINOGRAM RESTORATION INDUCED EDGE-PRESERVING PRIOR
    Bian, Zhaoying
    Huang, Jing
    Ma, Jianhua
    Zhang, Hua
    Liang, Zhengrong
    Chen, Wufan
    2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 1160 - 1163
  • [5] Iterative image reconstruction in helical cone-beam x-ray CT using a stored system matrix approach
    Xu, Jingyan
    Tsui, Benjamin M. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11): : 3477 - 3497
  • [6] Low Dose CT Reconstruction with Nonlocal Means-based Prior Predicted from Normal-dose CT Database
    Rong, Junyan
    Zhang, Yuanke
    Liu, Tianshuai
    Gao, Peng
    Xing, Yuxiang
    Liang, Zhengrong
    Lu, Hongbing
    MEDICAL IMAGING 2018: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2018, 10578
  • [7] Low-dose CT reconstruction method based on prior information of normal-dose image
    Chen, Zixiang
    Zhang, Qiyang
    Zhou, Chao
    Zhang, Mengxi
    Yang, Yongfeng
    Liu, Xin
    Zheng, Hairong
    Liang, Dong
    Hu, Zhanli
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (06) : 1091 - 1111
  • [8] Iterative volume of interest image reconstruction in helical cone beam X-Ray CT using a stored system matrix approach
    Xu, Jingyan
    Tsui, Benjamin M. W.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [9] Improving iterative image reconstruction for X-ray CT
    Dinis Almeida, Pedro Miguel
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (08) : 1062 - 1062
  • [10] Assessment of Absorbed Dose and Image Quality Using Cone Beam CT On An X-Ray Angiography System
    Supanich, M.
    Vanderhoek, M.
    MEDICAL PHYSICS, 2013, 40 (06)