Extended imaging volume in cone-beam x-ray tomography using the weighted simultaneous iterative reconstruction technique

被引:8
|
作者
Sanctorum, Joaquim G. [1 ]
Van Wassenbergh, Sam [2 ]
Van Nguyen [3 ]
De Beenhouwer, Jan [3 ]
Sijbers, Jan [3 ]
Dirckx, Joris J. J. [1 ]
机构
[1] Univ Antwerp, Lab Biophys & Biomed Phys BIMEF, Antwerp, Belgium
[2] Univ Antwerp, Lab Funct Morphol FunMorph, Antwerp, Belgium
[3] Univ Antwerp, Imec Vis Lab, Antwerp, Belgium
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2021年 / 66卷 / 16期
关键词
x-ray tomography; detector offset; field-of-view; image intensifier; cone-beam; SIRT; CT;
D O I
10.1088/1361-6560/ac16bc
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An issue in computerized x-ray tomography is the limited size of available detectors relative to objects of interest. A solution was provided in the past two decades by positioning the detector in a lateral offset position, increasing the effective field of view (FOV) and thus the diameter of the reconstructed volume. However, this introduced artifacts in the obtained reconstructions, caused by projection truncation and data redundancy. These issues can be addressed by incorporating an additional data weighting step in the reconstruction algorithms, known as redundancy weighting. In this work, we present an implementation of redundancy weighting in the widely-used simultaneous iterative reconstruction technique (SIRT), yielding the weighted SIRT (W-SIRT) method. The new technique is validated using geometric phantoms and a rabbit specimen, by performing both simulation studies as well as physical experiments. The experiments are carried out in a highly flexible stereoscopic x-ray system equipped with x-ray image intensifiers (XRIIs). The simulations showed that higher values of contrast-to-noise ratio could be obtained using the W-SIRT approach as compared to a weighted implementation of the simultaneous algebraic reconstruction technique (SART). The convergence rate of the W-SIRT was accelerated by including a relaxation parameter in the W-SIRT algorithm, creating the aW-SIRT algorithm. This allowed to obtain the same results as the W-SIRT algorithm, but at half the number of iterations, yielding a much shorter computation time. The aW-SIRT algorithm has proven to perform well for both large as well as small regions of overlap, outperforming the pre-convolutional Feldkamp-David-Kress algorithm for small overlap regions (or large detector offsets). The experiments confirmed the results of the simulations. Using the aW-SIRT algorithm, the effective FOV was increased by >75%, only limited by experimental constraints. Although an XRII is used in this work, the method readily applies to flat-panel detectors as well.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Development and operation of a prototype cone-beam computed tomography system for X-ray medical imaging
    Seo, Chang-Woo
    Cha, Bo Kyung
    Kim, Ryun Kyung
    Kim, Cho-Rong
    Yang, Keedong
    Huh, Young
    Jeon, Sungchae
    Park, Justin C.
    Song, Bongyong
    Song, William Y.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (01) : 129 - 134
  • [22] Excitation-resolved cone-beam x-ray luminescence tomography
    Liu, Xin
    Liao, Qimei
    Wang, Hongkai
    Yan, Zhuangzhi
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (07)
  • [23] Optimal x-ray imaging geometry for flat-panel cone-beam computed tomography
    Siewerdsen, JH
    Jaffray, DA
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 106 - 107
  • [24] Development and operation of a prototype cone-beam computed tomography system for X-ray medical imaging
    Chang-Woo Seo
    Bo Kyung Cha
    Ryun Kyung Kim
    Cho-Rong Kim
    Keedong Yang
    Young Huh
    Sungchae Jeon
    Justin C. Park
    Bongyong Song
    William Y. Song
    Journal of the Korean Physical Society, 2014, 64 : 129 - 134
  • [25] X-ray Cone-Beam Breast Computed Tomography: phantom studies
    Russo, P.
    Lauria, A.
    Mettivier, G.
    Montesi, M. C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4076 - 4083
  • [26] X-ray Cone-Beam Breast Computed Tomography: Phantom Studies
    Russo, Paolo
    Mettivier, Giovanni
    Lauria, Adele
    Montesi, Maria Cristina
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 160 - 172
  • [27] Multi-mounted X-ray cone-beam computed tomography
    Fu, Jian
    Wang, Jingzheng
    Guo, Wei
    Peng, Peng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 888 : 119 - 125
  • [28] FPGA-acceleration of cone-beam reconstruction for the X-ray CT
    Stsepankou, D
    Kornmesser, K
    Hesser, J
    Männer, R
    2004 IEEE INTERNATIONAL CONFERENCE ON FIELD-PROGRAMMABLE TECHNOLOGY, PROCEEDINGS, 2004, : 327 - 330
  • [29] An accelerated RAMLA reconstruction algorithm for X-ray cone-beam CT
    Zhao, Xing
    Hu, Jing-jing
    Yang, Tao
    Wang, Feng
    INSIGHT, 2013, 55 (05) : 237 - 242
  • [30] X-ray volume cone-beam imaging using kilo-voltage projections acquired between treatment beam delivery
    Simpson, P
    Amer, A
    Sykes, J
    Moore, C
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S231 - S231