Validation and performance comparison of different types of combined scintillation detectors for animal PET imaging system using GATE simulation

被引:2
|
作者
Sadremomtaz, A. [1 ]
Ghalebin, M. Mohammadi [1 ]
机构
[1] Univ Guilan, Dept Phys, Namjoo St, Rasht, Iran
关键词
Detector modelling and simulations I (interaction of radiation with matter; interaction of photons with matter; interaction of hadrons with matter; etc); Detector modelling and simulations II (electric fields; charge transport; multiplication and induction; pulse formation; electron emission; Photon detectors for UV; visible and IR photons (vacuum) (photomultipliers; HPDs; others); Radiation-induced secondary-electron emission; SCANNER; NEMA;
D O I
10.1088/1748-0221/17/05/T05017
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The selection of suitable high-efficiency scintillation detectors plays an essential role in improving the quality of PET images. Many studies have used two layers of crystal detectors with different scintillation materials. This research uses GATE simulation to simulate an animal PET system with a two-layer detector. By varying the type of the crystal detectors, essential parameters such as sensitivity, scatter fraction, noise equivalent counting rate, spatial resolution, energy resolution, and time resolution for different scintillation materials were calculated and compared to determine the most efficient solutions. This simulation used scintillating materials; LYSO, GSO, LSO, BGO, YAP, LuAP, and LPS in 12 different states. Results showed that by increasing the distance of the source from the center in the radial direction, the two-layer crystals with different scintillation materials have a better radial spatial resolution than the same material of crystals. As a general result, the PET system???s performance, designed from two-layer crystals with different scintillation materials, lower layer LuAP and upper layer BGO or same-material of BGO, is more desirable than the rest.
引用
收藏
页数:13
相关论文
共 23 条
  • [11] Performance comparison of Si-PM-based block detectors with different pixel sizes for an ultrahigh-resolution small-animal PET system
    Yamamoto, Seiichi
    Watabe, Hiroshi
    Hatazawa, Jun
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20): : N227 - N236
  • [12] GATE Simulation of 12C Hadrontherapy Treatment Combined With a PET Imaging System for Dose Monitoring: A Feasibility Study
    Jan, Sebastien
    Frisson, Thibault
    Sarrut, David
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (01) : 423 - 429
  • [13] Comparison of a GATE Monte Carlo Simulation Predictions to the Performance of a High-Resolution LYSO Based Dedicated Animal PET Camera
    Baghaei, Hossain
    Zhang, Yuxuan
    Li, Hongdi
    Ramirez, Rocio A.
    Liu, Shitao
    Wang, Chao
    An, Shaohui
    Wong, Wai-Hoi
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 2388 - 2392
  • [14] Assessment of the Mosaic animal PET system response using list-mode data for validation of GATE Monte Carlo modelling
    Merheb, Charbel
    Nicol, Stan
    Petegnief, Yolande
    Talbot, Jean-Noel
    Buvat, Irene
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (02): : 220 - 224
  • [15] Monte Carlo simulation of two Siemens Biograph PET/CT system using GATE: Image quality performance
    Saaidi, Rahal
    Zeghari, Abdelkrim
    El Moursli, Rajaa Cherkaoui
    RADIATION PHYSICS AND CHEMISTRY, 2024, 218
  • [16] Monte Carlo simulation of Ray-Scan 64 PET system and performance evaluation using GATE toolkit
    Li, Suying
    Zhang, Qiushi
    Vuletic, Ivan
    Xie, Zhaoheng
    Yang, Kun
    Ren, Qiushi
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [17] Design considerations for a C-shaped PET system, dedicated to small animal brain imaging, using GATE Monte Carlo simulations
    Efthimiou, N.
    Papadimitroulas, P.
    Kostou, T.
    Loudos, G.
    INTERNATIONAL CONFERENCE ON BIO-MEDICAL INSTRUMENTATION AND RELATED ENGINEERING AND PHYSICAL SCIENCES (BIOMEP 2015), 2015, 637
  • [18] Performance of a Novel Small-Animal SPECT System with Two Stationary Detectors: A Comparison of Multi-Pinhole Collimators for Mouse Imaging
    Hoffmann, J.
    Janssen, J.
    Kanno, T.
    Higuchi, T.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S453 - S453
  • [19] Assessment of metastatic colorectal cancer with hybrid imaging: comparison of reading performance using different combinations of anatomical and functional imaging techniques in PET/MRI and PET/CT in a short case series
    C. Brendle
    N. F. Schwenzer
    H. Rempp
    H. Schmidt
    C. Pfannenberg
    C. la Fougère
    K. Nikolaou
    C. Schraml
    European Journal of Nuclear Medicine and Molecular Imaging, 2016, 43 : 123 - 132
  • [20] Assessment of metastatic colorectal cancer with hybrid imaging: comparison of reading performance using different combinations of anatomical and functional imaging techniques in PET/MRI and PET/CT in a short case series
    Brendle, C.
    Schwenzer, N. F.
    Rempp, H.
    Schmidt, H.
    Pfannenberg, C.
    la Fougere, C.
    Nikolaou, K.
    Schraml, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (01) : 123 - 132