Design considerations for a C-shaped PET system, dedicated to small animal brain imaging, using GATE Monte Carlo simulations

被引:0
|
作者
Efthimiou, N. [1 ]
Papadimitroulas, P. [2 ]
Kostou, T. [2 ]
Loudos, G. [1 ]
机构
[1] Technol Educ Inst Athens, Dept Biomed Engn, Egaleo, Greece
[2] Univ Patras, Sch Med, Dept Med Phys, GR-26110 Patras, Greece
关键词
NUCLEAR-MEDICINE; RESOLUTION; THERAPY; BREAST;
D O I
10.1088/1742-6596/637/1/012005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Commercial clinical and preclinical PET scanners rely on the full cylindrical geometry for whole body scans as well as for dedicated organs. In this study we propose the construction of a low cost dual-head C-shaped PET system dedicated for small animal brain imaging. Monte Carlo simulation studies were performed using GATE toolkit to evaluate the optimum design in terms of sensitivity, distortions in the FOV and spatial resolution. The PET model is based on SiPMs and BGO pixelated arrays. Four different configurations with C-angle 0 degrees, 15 degrees, 30 degrees and 45 degrees within the modules, were considered. Geometrical phantoms were used for the evaluation process. STIR software, extended by an efficient multi-threaded ray tracing technique, was used for the image reconstruction. The algorithm automatically adjusts the size of the FOV according to the shape of the detector's geometry. The results showed improvement in sensitivity of similar to 15% in case of 45 degrees C-angle compared to the 0 degrees case. The spatial resolution was found 2 mm for 45 degrees C-angle.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Monte Carlo simulations studies in small animal PET using GATE
    Branco, S.
    Jan, S.
    Almeida, P.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3994 - +
  • [2] Monte Carlo simulations in small animal PET imaging
    Branco, Susana
    Jan, Sebastien
    Almeida, Pedro
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 1127 - 1130
  • [3] Design of a new dedicated brain PET system using Monte Carlo methods
    Moghaddam, N. Mortazavi
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S158 - S158
  • [4] Respiratory motion in small animal PET using Monte Carlo simulations
    Branco, S.
    Jan, S.
    Almeida, P.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S175 - S175
  • [5] Monte Carlo simulations studies in small animal PET
    Branco, S.
    Almeida, P.
    Jan, S.
    [J]. COMPUTATIONAL MODELLING OF OBJECTS REPRESENTED IN IMAGES: FUNDAMENTALS, METHODS AND APPLICATIONS, 2007, : 111 - 115
  • [6] Monte Carlo simulation of a CsI(Tl) gamma camera dedicated to small animal imaging using GATE.
    Lazaro, D
    Buvat, I
    Donnarieix, D
    Loudos, G
    Giokaris, N
    Strul, D
    Santin, G
    Maigne, L
    Spanoudaki, V
    Styliaris, S
    Staelens, S
    Breton, V
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 288P - 288P
  • [7] Molecular imaging of small animals PET using Monte Carlo simulations
    Branco, S.
    Jan, S.
    Almeida, P.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S227 - S227
  • [8] Monte Carlo database production for human brain PET imaging using GATE
    Jan, S.
    Comtat, C.
    Trebossen, R.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3159 - 3162
  • [9] Analytic and Monte Carlo Derived System Matrices for Small Animal PET Imaging
    Schirmer, J.
    Torres-Espallardo, I.
    Minde, J.
    Spanoudaki, V.
    Trager, R.
    Ziegler, S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S176 - S176
  • [10] Monte Carlo simulations of an innovative molecular breast imaging system for the small breast cancer diagnosis using GATE
    Poma, G. E.
    Garibaldi, F.
    Giuliani, F.
    Insero, T.
    Lucentini, M.
    Marcucci, A.
    Musico, P.
    Petta, C.
    Santavenere, F.
    Sutera, C.
    Cisbani, E.
    [J]. RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2019, 174 (11-12): : 1008 - 1019