Monte Carlo simulation of Ray-Scan 64 PET system and performance evaluation using GATE toolkit

被引:2
|
作者
Li, Suying [1 ]
Zhang, Qiushi [2 ]
Vuletic, Ivan [1 ]
Xie, Zhaoheng [1 ]
Yang, Kun [3 ]
Ren, Qiushi [1 ]
机构
[1] Peking Univ, Dept Biomed Engn, Coll Engn, 5 Yiheyuan Rd, Beijing 100871, Peoples R China
[2] PLA, Hlth Dept GLD, Inst Drug & Instrument Control, 17 Fengtai West Rd, Beijing 100071, Peoples R China
[3] Hebei Univ, Coll Qual & Tech Supervis, Dept Control Technol & Instrumentat, 180 Wusidong Rd, Baoding, Peoples R China
来源
关键词
Detector modelling and simulations I (interaction of radiation with matter; interaction of photons with matter; interaction of hadrons with matter; etc); Gamma camera; SPECT; PET; PET/CT; coronary CT angiography (CTA); Models and simulations; Simulation methods and programs;
D O I
10.1088/1748-0221/12/02/T02001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this study, we aimed to develop a GATE model for the simulation of Ray-Scan 64 PET scanner and model its performance characteristics. A detailed implementation of system geometry and physical process were included in the simulation model. Then we modeled the performance characteristics of Ray-Scan 64 PET system for the first time, based on National Electrical Manufacturers Association (NEMA) NU-2 2007 protocols and validated the model against experimental measurement, including spatial resolution, sensitivity, counting rates and noise equivalent count rate (NECR). Moreover, an accurate dead time module was investigated to simulate the counting rate performance. Overall results showed reasonable agreement between simulation and experimental data. The validation results showed the reliability and feasibility of the GATE model to evaluate major performance of Ray-Scan 64 PET system. It provided a useful tool for a wide range of research applications.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Monte Carlo simulation of MAMMI PET system and performance evaluation using GATE toolkit
    Emami, A.
    Ghadiri, H.
    Ghafarian, P.
    Geramifar, P.
    Ay, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S714 - S714
  • [2] Ray-Scan 64 PET/CT performance evaluation and clinical application
    Li, Suying
    Zhou, Kun
    Xie, Zhaoheng
    Yang, Kun
    Ren, Qiushi
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [3] RAY-SCAN 64 PET/CT性能测试与临床测试
    田涧
    丁翼晨
    杨昆
    任秋实
    [J]. 中国医疗设备, 2015, 30 (02) : 11 - 15
  • [4] Performance tests for ray-scan 64 PET/CT based on NEMA NU-2 2007
    Li, Suying
    Zhou, Kun
    Zhang, Qiushi
    Zhang, Jinming
    Yang, Kun
    Xu, Baixuan
    Ren, Qiushi
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [5] Performance characteristics of NeuroPET system using GATE Monte Carlo simulation
    Sheikhzadeh, P.
    Sabet, H.
    Ghadiri, H.
    Geramifar, P.
    Mahani, H.
    Ghafarian, P.
    Ay, M.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S512 - S513
  • [6] Monte Carlo simulation in PET and SPECT instrumentation using GATE
    Assié, K
    Breton, V
    Buvat, I
    Comtat, C
    Jan, S
    Krieguer, M
    Lazaro, D
    Morel, C
    Rey, M
    Santin, G
    Simon, L
    Staelens, S
    Strul, D
    Vieira, JM
    Van de Walle, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2): : 180 - 189
  • [7] Monte Carlo simulation of two Siemens Biograph PET/CT system using GATE: Image quality performance
    Saaidi, Rahal
    Zeghari, Abdelkrim
    El Moursli, Rajaa Cherkaoui
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2024, 218
  • [8] Performance evaluation of Biograph PET/CT system based on Monte Carlo simulation
    Wang Bing
    Gao Fei
    Liu Hua-Feng
    [J]. 5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: SMART STRUCTURES AND MATERIALS IN MANUFACTURING AND TESTING, 2010, 7659
  • [9] Validation of a Monte Carlo simulation of the Inveon PET scanner using GATE
    Lu, Lijun
    Zhang, Houjin
    Bian, Zhaoying
    Ma, Jianhua
    Feng, Qiangjin
    Chen, Wufan
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 828 : 170 - 175
  • [10] A Monte Carlo Simulation of PET of a Real Patient with GATE
    Gerganov, G.
    Kang, H.
    Madzhunkov, Y.
    Mitev, K.
    Schmidtlein, C. R.
    Kawrakow, I.
    Kirov, A.
    [J]. NUCLEAR PHYSICS METHODS AND ACCELERATORS IN BIOLOGY AND MEDICINE, 2009, 1204 : 219 - +