The importance of accurate linear accelerator head modelling for IMRT Monte Carlo calculations

被引:16
|
作者
Reynaert, N
Coghe, M
De Smedt, B
Paelinck, L
Vanderstraeten, B
De Gersem, W
Van Duyse, B
De Wagter, C
De Neve, W
Thierens, H
机构
[1] State Univ Ghent, Dept Med Phys, B-9000 Ghent, Belgium
[2] State Univ Ghent Hosp, Div Radiotherapy, B-9000 Ghent, Belgium
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 05期
关键词
D O I
10.1088/0031-9155/50/5/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two Monte Carlo dose engines for radiotherapy treatment planning, namely a beta release of Peregrine and MCDE (Monte Carlo dose engine), were compared with Helax-TMS (collapsed cone superposition convolution) for a head and neck patient for the Elekta SLi plus linear accelerator. Deviations between the beta release of Peregrine and MCDE up to 10% were obtained in the dose volume histogram of the optical chiasm. It was illustrated that the differences are not caused by the particle transport in the patient, but by the modelling of the Elekta SLi plus accelerator head and more specifically the multileaf collimator (MLC). In MCDE two MLC modules (MLCQ and MLCE) were introduced to study the influence of the tongue-and-groove geometry, leaf bank tilt and leakage on the actual dose volume histograms. Differences in integral dose in the optical chiasm up to 3% between the two modules have been obtained. For single small offset beams though the FWHM of lateral profiles obtained with MLCE can differ by more than 1.5 mm from profiles obtained with MLCQ. Therefore, and because the recent version of MLCE is as fast as MLCQ, we advise to use MLCE for modelling the Elekta MLC. Nevertheless there still remains a large difference (up to 10%) between Peregrine and MCDE. By studying small offset beams we have shown that the profiles obtained with Peregrine are shifted, too wide and too flat compared with MCDE and phantom measurements. The overestimated integral doses for small beam segments explain the deviations observed in the dose volume histograms. The Helax-TMS results are in better agreement with MCDE, although deviations exceeding 5% have been observed in the optical chiasm. Monte Carlo dose deviations of more than 10% as found with Peregrine are unacceptable as an influence on the clinical outcome is possible and as the purpose of Monte Carlo treatment planning is to obtain an accuracy of 2%. We would like to emphasize that only the Elekta MLC has been tested in this work, so it is certainly possible that alpha releases of Peregrine provide more accurate results for other accelerators.
引用
下载
收藏
页码:831 / 846
页数:16
相关论文
共 50 条
  • [31] Monte Carlo-based QA for IMRT of head and neck cancers
    Tang, F.
    Sham, J.
    Ma, C-M
    Li, J-S
    FIRST EUROPEAN WORKSHOP ON MONTE CARLO TREATMENT PLANNING, 2007, 74
  • [32] Monte Carlo evaluation of IMRT plans for head and neck and lung treatments
    Wang, L
    Yorke, E
    Chui, C
    RADIOLOGY, 2001, 221 : 600 - 601
  • [33] Accurate spectroscopic properties by diffusion quantum Monte Carlo calculations
    Carvalho, Cassius M. C.
    Gargano, Ricardo
    Martins, Joao B. L.
    Politi, Jose Roberto S.
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 243
  • [34] Accurate rotational barrier calculations with diffusion quantum Monte Carlo
    Klahm, Sebastian
    Luechow, Arne
    CHEMICAL PHYSICS LETTERS, 2014, 600 : 7 - 9
  • [35] Accurate forces in quantum Monte Carlo calculations with nonlocal pseudopotentials
    Badinski, A.
    Needs, R. J.
    PHYSICAL REVIEW E, 2007, 76 (03):
  • [36] Monte Carlo modeling of linear accelerator using distributed computing
    Stathakis, Sotirios
    Balbi, Federico
    Chronopoulos, Anthony T.
    Papanikolaou, Niko
    JOURNAL OF BUON, 2016, 21 (01): : 252 - 260
  • [37] Monte Carlo simulation of a medical linear accelerator for radiotherapy use
    Serrano, B.
    Hachem, A.
    Franchisseur, E.
    Herault, J.
    Marcie, S.
    Costa, A.
    Bensadoun, R. J.
    Barthe, J.
    Gerard, J. P.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 506 - 509
  • [38] The Importance of Accurate X-ray Energy Spectra for Modelling Dose Deposition with Monte Carlo Techniques
    Forth, Logan
    Speller, Robert
    Moss, Rob
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [39] Linear-scaling quantum Monte Carlo calculations
    Williamson, AJ
    Hood, RQ
    Grossman, JC
    PHYSICAL REVIEW LETTERS, 2001, 87 (24) : 246406 - 1
  • [40] Monte Carlo simulation for Neptun 10 PC medical linear accelerator and calculations of output factor for electron beam
    Toossi, Mohammad Taghi Bahreyni
    Momennezhad, Mehdi
    Hashemi, Seyed Mohammad
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2012, 17 (02) : 115 - 118