Experimental investigation of heat and moisture transfer performance of CaCl2/H2O-SiO2 nanofluid in a gas-liquid microporous hollow fiber membrane contactor

被引:33
|
作者
Zheng, Yuanzhou [1 ,2 ]
Yang, Haoran [1 ,2 ]
Fazilati, Mohammad Ali [3 ]
Toghraie, Davood [3 ]
Rahimi, Hossein [3 ]
Afrand, Masoud [4 ,5 ]
机构
[1] Wuhan Univ Technol, Hubei Key Lab Inland Shipping Technol, 588 Youyi Ave, Wuhan, Peoples R China
[2] Wuhan Univ Technol, Sch Nav, 588 Youyi Ave, Wuhan, Peoples R China
[3] Islamic Azad Univ, Dept Mech Engn, Khomeinishahr Branch, Khomeinishahr, Iran
[4] Ton Duc Thang Univ, Adv Inst Mat Sci, Lab Magnetism & Magnet Mat, Ho Chi Minh City, Vietnam
[5] Ton Duc Thang Univ, Fac Appl Sci, Ho Chi Minh City, Vietnam
基金
中国国家自然科学基金;
关键词
Hollow fiber membrane; Air dehumidification; Aqueous solution of calcium chloride; SiO2; nanoparticles; AIR-CONDITIONING SYSTEM; MASS-TRANSFER; THERMAL-CONDUCTIVITY; HYBRID NANOFLUID; CO2; ABSORPTION; DEHUMIDIFICATION PERFORMANCE; REGENERATION PERFORMANCE; RHEOLOGICAL BEHAVIOR; NATURAL-CONVECTION; LICL SOLUTION;
D O I
10.1016/j.icheatmasstransfer.2020.104533
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, aqueous solution of CaCl2/SiO2 nanoparticles has been used as a desiccant in a gas-liquid hollow fiber membrane (HFM) air dehumidifier contactor system. The heat and mass (H/M) transfer properties HFM energy exchanger with CaCl2/H2O-SiO2 as desiccant solution studied experimentally for first time. Effects of different parameters on H/M transfer characteristics of system, including the nanoparticle concentration, liquid flow rate and liquid temperature were examined experimentally. The experiments arranged for desiccant temperatures of 20 degrees C and 26 degrees C, desiccant solutions of 0, 1%wt and 2%wt concentration and flow rates of 1.1, 1.25, 1.4 and 1.7 ml/s. The results indicated that the influence of particles on moisture removal rate is the greatest for the conditions of highest solution temperature and the highest particle. By introducing nanofluid solution as liquid desiccant in system the enhancing effect of reducing desiccant temperature on moisture removal lessens and declined to zero by increasing the solution flow rate with a high descending rate. For 2%wt nanoparticle concentration by 53% increase of absorbent flow rate, the value of temperature effectiveness reduced by 30%. This justifies adiabatic application of hollow fiber membrane systems with nanofluid desiccant.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Experimental investigation of heat transfer of Al2O3 nanofluid in a microchannel heat sink
    Jung, Sung Yong
    Park, Hanwook
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 179
  • [42] Prediction of CO2/O2 absorption selectivity using supported ionic liquid membranes (SILMs) for gas-liquid membrane contactor
    Ramli, N. Ain
    Hashim, N. Awanis
    Aroua, M. K.
    CHEMICAL ENGINEERING COMMUNICATIONS, 2018, 205 (03) : 295 - 310
  • [43] CO2/CH4 separation performance of SiO2/PES composite membrane prepared by gas phase hydrolysis and grafting coating in gas-liquid membrane contactor: A comparative study
    Lin, Zhengda
    Zhang, Dandan
    Liu, Yijun
    Zhang, Zhongming
    Zhao, Zhiying
    Shao, Bo
    Wu, Rui
    Fang, Rui
    Yao, Jie
    HELIYON, 2023, 9 (08)
  • [44] Performance evaluation of composite and microporous gas-liquid membrane contactors for CO2 removal from a gas mixture
    Amaral, R. A.
    Habert, A. C.
    Borges, C. P.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2016, 102 : 202 - 209
  • [45] Evaluation of a dense skin hollow fiber gas-liquid membrane contactor for high pressure removal of CO2 from syngas using Selexol as the absorbent
    Belaissaoui, Bouchra
    Favre, Eric
    CHEMICAL ENGINEERING SCIENCE, 2018, 184 : 186 - 199
  • [46] Theoretical modeling of the mass transfer performance of CO2 absorption into DEAB solution in hollow fiber membrane contactor
    Cao, Fan
    Gao, Hongxia
    Ling, Hao
    Huang, Yangqiang
    Liang, Zhiwu
    JOURNAL OF MEMBRANE SCIENCE, 2020, 593
  • [47] Hydrophobicity optimization of polypropylene hollow fiber membrane by sol-gel process for CO2 absorption in gas-liquid membrane contactor using response surface methodology
    Amirabedi, Parya
    Yegani, Reza
    Hesaraki, Amir Hossein
    IRANIAN POLYMER JOURNAL, 2017, 26 (06) : 431 - 443
  • [48] A correlation of nanofluid flow boiling heat transfer based on the experimental results of AlN/H2O and Al2O3/H2O nanofluid
    Wang, Y.
    Deng, K. H.
    Liu, B.
    Wu, J. M.
    Su, G. H.
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 80 : 376 - 383
  • [49] An experimental study on the heat transfer performance of a radiator using MWCNT-SiO2 hybrid nanofluid
    Tetik, Tugba
    Armagan, Mustafa
    Demir, Emir Kasim
    Arbak, Altay
    Teksan, A. Emre
    Pusat, Saban
    Karagoz, Yasin
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (04) : 12590 - 12603
  • [50] Experimental study of gas-liquid heat transfer in a 2-phase flow in a packed bed
    Niegodajew, Pawel
    Asendrych, Dariusz
    7TH EUROPEAN THERMAL-SCIENCES CONFERENCE (EUROTHERM2016), 2016, 745