Experimental investigation of heat and moisture transfer performance of CaCl2/H2O-SiO2 nanofluid in a gas-liquid microporous hollow fiber membrane contactor

被引:33
|
作者
Zheng, Yuanzhou [1 ,2 ]
Yang, Haoran [1 ,2 ]
Fazilati, Mohammad Ali [3 ]
Toghraie, Davood [3 ]
Rahimi, Hossein [3 ]
Afrand, Masoud [4 ,5 ]
机构
[1] Wuhan Univ Technol, Hubei Key Lab Inland Shipping Technol, 588 Youyi Ave, Wuhan, Peoples R China
[2] Wuhan Univ Technol, Sch Nav, 588 Youyi Ave, Wuhan, Peoples R China
[3] Islamic Azad Univ, Dept Mech Engn, Khomeinishahr Branch, Khomeinishahr, Iran
[4] Ton Duc Thang Univ, Adv Inst Mat Sci, Lab Magnetism & Magnet Mat, Ho Chi Minh City, Vietnam
[5] Ton Duc Thang Univ, Fac Appl Sci, Ho Chi Minh City, Vietnam
基金
中国国家自然科学基金;
关键词
Hollow fiber membrane; Air dehumidification; Aqueous solution of calcium chloride; SiO2; nanoparticles; AIR-CONDITIONING SYSTEM; MASS-TRANSFER; THERMAL-CONDUCTIVITY; HYBRID NANOFLUID; CO2; ABSORPTION; DEHUMIDIFICATION PERFORMANCE; REGENERATION PERFORMANCE; RHEOLOGICAL BEHAVIOR; NATURAL-CONVECTION; LICL SOLUTION;
D O I
10.1016/j.icheatmasstransfer.2020.104533
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, aqueous solution of CaCl2/SiO2 nanoparticles has been used as a desiccant in a gas-liquid hollow fiber membrane (HFM) air dehumidifier contactor system. The heat and mass (H/M) transfer properties HFM energy exchanger with CaCl2/H2O-SiO2 as desiccant solution studied experimentally for first time. Effects of different parameters on H/M transfer characteristics of system, including the nanoparticle concentration, liquid flow rate and liquid temperature were examined experimentally. The experiments arranged for desiccant temperatures of 20 degrees C and 26 degrees C, desiccant solutions of 0, 1%wt and 2%wt concentration and flow rates of 1.1, 1.25, 1.4 and 1.7 ml/s. The results indicated that the influence of particles on moisture removal rate is the greatest for the conditions of highest solution temperature and the highest particle. By introducing nanofluid solution as liquid desiccant in system the enhancing effect of reducing desiccant temperature on moisture removal lessens and declined to zero by increasing the solution flow rate with a high descending rate. For 2%wt nanoparticle concentration by 53% increase of absorbent flow rate, the value of temperature effectiveness reduced by 30%. This justifies adiabatic application of hollow fiber membrane systems with nanofluid desiccant.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] An experimental investigation of heat transfer enhancement of a minichannel heat sink using Al2O3-H2O nanofluid
    Sohel, M. R.
    Khaleduzzaman, S. S.
    Saidur, R.
    Hepbasli, A.
    Sabri, M. F. M.
    Mahbubul, I. M.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 74 : 164 - 172
  • [22] Study on the heat transfer characteristics of CO2 and liquid desiccant CaCl2 aqueous solution in the gas cooler and evaporator
    Wei, Dianhang
    Cui, Qi
    Gao, Enyuan
    Qi, Pengcheng
    Zhang, Xiaosong
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2024, 197
  • [23] A COMPARATIVE INVESTIGATION OF Al2O3/H2O, SiO2/H2O AND ZrO2/H2O NANOFLUID FOR HEAT TRANSFER APPLICATIONS
    Iqbal, S. M.
    Raj, C. S.
    Michael, J. J.
    Irfan, A. M.
    DIGEST JOURNAL OF NANOMATERIALS AND BIOSTRUCTURES, 2017, 12 (02) : 255 - 263
  • [24] Enhanced heat storage performance of CaCl2·6H2O using BN nanosheet as an additive
    Qian Zhang
    Fukun Ma
    Wenjie Tan
    Liqiang Liu
    Min Jing
    Tao Sun
    Heat and Mass Transfer, 2023, 59 : 851 - 857
  • [25] Enhanced heat storage performance of CaCl2•6H2O using BN nanosheet as an additive
    Zhang, Qian
    Ma, Fukun
    Tan, Wenjie
    Liu, Liqiang
    Jing, Min
    Sun, Tao
    HEAT AND MASS TRANSFER, 2023, 59 (05) : 851 - 857
  • [26] An electrolytic bubble column with an external hollow fiber membrane gas-liquid contactor for effective microbial electrosynthesis of acetate from CO2
    Cui, Kai
    Guo, Kun
    Carvajal-Arroyo, Jose M.
    Arends, Jan
    Rabaey, Korneel
    CHEMICAL ENGINEERING JOURNAL, 2023, 471
  • [27] Novel method for incorporating hydrophobic silica nanoparticles on polyetherimide hollow fiber membranes for CO2 absorption in a gas-liquid membrane contactor
    Zhang, Yuan
    Wang, Rong
    JOURNAL OF MEMBRANE SCIENCE, 2014, 452 : 379 - 389
  • [28] Experimental investigation on heat transfer characteristic of TiO2-H2O nanofluid in microchannel for thermal energy storage
    Ding, Mingyue
    Liu, Chenzhen
    Rao, Zhonghao
    APPLIED THERMAL ENGINEERING, 2019, 160
  • [29] Effect of polymer extrusion temperature on poly(vinylidene fluoride) hollow fiber membranes: Properties and performance used as gas-liquid membrane contactor for CO2 absorption
    Ghasem, Nayef
    Al-Marzouqi, Mohamed
    Rahim, Nihmiya Abdul
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 99 : 91 - 103
  • [30] Preparation of heat-treated PAN/SiO2 hybrid hollow fiber membrane contactor for acetylene absorption
    Gao, Jia
    Wang, Xiaoxu
    Zhang, Jianshu
    Guo, Ruili
    SEPARATION AND PURIFICATION TECHNOLOGY, 2016, 159 : 116 - 123