Performance Evaluation of Ceiling Mounted Personalized Ventilation System

被引:0
|
作者
Yang, Bin [1 ]
Melikov, Arsen [3 ]
Sekhar, Chandra [2 ]
机构
[1] Natl Univ Singapore, NUS DTU Joint PhD Program, Singapore 117548, Singapore
[2] Natl Univ Singapore, Dept Bldg, Singapore, Singapore
[3] Tech Univ Denmark, Dept Civil Engn, Lyngby, Denmark
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The interaction of the personalized airflow supplied from ceiling mounted nozzle (diameter of 0.095 m (0.312ft)) with the thermal plume generated by a seated thermal manikin with the body size of an average Scandinavian woman and its impact on the body cooling was studied. Experiments were performed in a test room with mixing ventilation at numerous conditions comprising four combinations of room air temperature and personalized air temperature (23.5 degrees C (74.3 F)/21 degrees C (69.8 degrees F), 23.5 degrees C (74.3 degrees F)/23.5 degrees C (74.3 degrees F), 26 degrees C (78.8 degrees F)/ 23.5 degrees C (74.3 degrees F), 26 degrees C (78.8 degrees F)/26 degrees C (78.8 degrees F)), four airflow rates of the personalized air (4 (8.48), 8 (16.95), 12 (25.43), 16 (33.91) L/s (cfm)) and positioning of the manikin directly below the nozzle (I.3m (4.265ft) distance between the top of manikin's head and the nozzle). The asymmetric exposure of the body to the personalized flow was studied by moving the manikin 0.2m (0.656ft) forward, backward and sideward. The blockage effect of the unheated manikin on the personalized airflow distribution, studied at the case 23.5 degrees C (74.3 degrees F)/23.5 degrees C (74.3 degrees F), was clearly observed 0.2m (0.656ft) above the top of manikin's head where the centerline velocity was reduced to about 85% under all personalized airflow rates. The neutral level, X-nl, defined as the distance from the nozzle where the impact of the thermal plume on the velocity distribution in the personalized airflow was observed, increased from 0.8m (2.625ft) to 1.1m (3.609ft) with the increase ofthe airflow rate. Above 16L/s (33.91 cfm) the personalized airflow was able to completely destroy the thermal plume. In comparison with the reference case without personalized airflow, the manikin based equivalent temperature for the head decreased with the increase of the airflow rate from -1 degrees C (-1.8 degrees F) to -6 degrees C (10.8 degrees F) under 23.5 degrees C (74.3 degrees F)/21 degrees C (69.8 degrees F) case and from -0.5 degrees C (-0.9 degrees F) to -4 degrees C (-7.2 degrees F) under 26 degrees C (78.8 degrees F)/26 degrees C (78.8 degrees F) case, which are the two extreme cases among the four cases studied. The personalized airflow was least efficient to cool the body when the manikin was moved forward.
引用
收藏
页码:395 / +
页数:3
相关论文
共 50 条
  • [41] Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system
    Zhang, Chen
    Heiselberg, Per Kvols
    Chen, Qingyan
    Pomianowski, Michal
    BUILDING SIMULATION, 2017, 10 (02) : 203 - 218
  • [42] Effect of shifts from occupant design position on performance of ceiling personalized ventilation assisted with desk fan or chair fans
    Habchi, Carine
    Chakroun, Walid
    Alotaibi, Sorour
    Ghali, Kamel
    Ghaddar, Nasreen
    ENERGY AND BUILDINGS, 2016, 117 : 20 - 32
  • [43] Numerical analysis of diffuse ceiling ventilation and its integration with a radiant ceiling system
    Chen Zhang
    Per Kvols Heiselberg
    Qingyan Chen
    Michal Pomianowski
    Building Simulation, 2017, 10 : 203 - 218
  • [44] Experimental study of ventilation performance and contaminant distribution of underfloor ventilation systems vs. traditional ceiling-based ventilation system
    Chao, CY
    Wan, MP
    INDOOR AIR, 2004, 14 (05) : 306 - 316
  • [45] Car park ventilation system: performance evaluation
    Chan, MY
    Chow, WK
    BUILDING AND ENVIRONMENT, 2004, 39 (06) : 635 - 643
  • [46] Performance comparison between mixing ventilation and displacement ventilation with and without cooled ceiling
    Wang, Qiu-Wang
    Zhao, Zhen
    ENGINEERING COMPUTATIONS, 2006, 23 (3-4) : 218 - 237
  • [47] Investigation of the displacement effect of a diffuse ceiling ventilation system
    Petersen, Steffen
    Christensen, Niels Uhre
    Heinsen, Caroline
    Hansen, Anne Sophie
    ENERGY AND BUILDINGS, 2014, 85 : 265 - 274
  • [48] Field evaluation of performance of radiant heating/cooling ceiling panel system
    Li, Rongling
    Yoshidomi, Togo
    Ooka, Ryozo
    Olesen, Bjarne W.
    ENERGY AND BUILDINGS, 2015, 86 : 58 - 65
  • [49] Effect of a ceiling fan ventilation system on finishing young bulls' health, behaviour and growth performance
    Magrin, L.
    Brscic, M.
    Lora, I.
    Rumor, C.
    Tondello, L.
    Cozzi, G.
    Gottardo, F.
    ANIMAL, 2017, 11 (06) : 1084 - 1092
  • [50] Performance of Mixing Ventilation System Coupled with Dynamic Personalized Ventilator for Thermal Comfort
    Al-Assaad, Douaa
    Ghaddar, Nesreen
    Ghali, Kamel
    PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2017, VOL 1, 2017,