Performance Evaluation of Ceiling Mounted Personalized Ventilation System

被引:0
|
作者
Yang, Bin [1 ]
Melikov, Arsen [3 ]
Sekhar, Chandra [2 ]
机构
[1] Natl Univ Singapore, NUS DTU Joint PhD Program, Singapore 117548, Singapore
[2] Natl Univ Singapore, Dept Bldg, Singapore, Singapore
[3] Tech Univ Denmark, Dept Civil Engn, Lyngby, Denmark
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The interaction of the personalized airflow supplied from ceiling mounted nozzle (diameter of 0.095 m (0.312ft)) with the thermal plume generated by a seated thermal manikin with the body size of an average Scandinavian woman and its impact on the body cooling was studied. Experiments were performed in a test room with mixing ventilation at numerous conditions comprising four combinations of room air temperature and personalized air temperature (23.5 degrees C (74.3 F)/21 degrees C (69.8 degrees F), 23.5 degrees C (74.3 degrees F)/23.5 degrees C (74.3 degrees F), 26 degrees C (78.8 degrees F)/ 23.5 degrees C (74.3 degrees F), 26 degrees C (78.8 degrees F)/26 degrees C (78.8 degrees F)), four airflow rates of the personalized air (4 (8.48), 8 (16.95), 12 (25.43), 16 (33.91) L/s (cfm)) and positioning of the manikin directly below the nozzle (I.3m (4.265ft) distance between the top of manikin's head and the nozzle). The asymmetric exposure of the body to the personalized flow was studied by moving the manikin 0.2m (0.656ft) forward, backward and sideward. The blockage effect of the unheated manikin on the personalized airflow distribution, studied at the case 23.5 degrees C (74.3 degrees F)/23.5 degrees C (74.3 degrees F), was clearly observed 0.2m (0.656ft) above the top of manikin's head where the centerline velocity was reduced to about 85% under all personalized airflow rates. The neutral level, X-nl, defined as the distance from the nozzle where the impact of the thermal plume on the velocity distribution in the personalized airflow was observed, increased from 0.8m (2.625ft) to 1.1m (3.609ft) with the increase ofthe airflow rate. Above 16L/s (33.91 cfm) the personalized airflow was able to completely destroy the thermal plume. In comparison with the reference case without personalized airflow, the manikin based equivalent temperature for the head decreased with the increase of the airflow rate from -1 degrees C (-1.8 degrees F) to -6 degrees C (10.8 degrees F) under 23.5 degrees C (74.3 degrees F)/21 degrees C (69.8 degrees F) case and from -0.5 degrees C (-0.9 degrees F) to -4 degrees C (-7.2 degrees F) under 26 degrees C (78.8 degrees F)/26 degrees C (78.8 degrees F) case, which are the two extreme cases among the four cases studied. The personalized airflow was least efficient to cool the body when the manikin was moved forward.
引用
收藏
页码:395 / +
页数:3
相关论文
共 50 条
  • [21] Chilled ceiling and displacement ventilation aided with personalized evaporative cooler
    Chakroun, W.
    Ghaddar, N.
    Ghali, K.
    ENERGY AND BUILDINGS, 2011, 43 (11) : 3250 - 3257
  • [22] Effects Of a Ceiling Diffuser On Diffuse Ceiling Ventilation (DCV) Performance
    Nocente, Alessandro
    Arslan, Tufan
    Grynning, Steinar
    Goia, Francesco
    PROCEEDINGS OF BUILDING SIMULATION 2019: 16TH CONFERENCE OF IBPSA, 2020, : 593 - 599
  • [23] Performance analysis of a new design of office diffuse ceiling ventilation system
    Fan, Jianhua
    Hviid, Christian Anker
    Yang, Honglu
    ENERGY AND BUILDINGS, 2013, 59 : 73 - 81
  • [24] Air distribution in a room with ceiling-mounted diffusers - Comparison with wall-mounted diffuser, vertical ventilation, and displacement ventilation
    Nielsen, Peter V.
    Heby, Thomas
    Moeller-Jensen, Bertil
    ASHRAE TRANSACTIONS 2006, VOL 112, PT 2, 2006, 112 : 498 - +
  • [25] Investigation of particle transport in offices equipped with ceiling-mounted personalized ventilators
    Makhoul, A.
    Ghali, K.
    Ghaddar, N.
    Chakroun, W.
    BUILDING AND ENVIRONMENT, 2013, 63 : 97 - 107
  • [26] Performance evaluation of displacement ventilation system combined with a novel evaporative cooled ceiling for a typical office in the city of Beirut
    Itani, Mariam
    Ghali, Kamel
    Ghaddar, Nesreen
    CLEAN, EFFICIENT AND AFFORDABLE ENERGY FOR A SUSTAINABLE FUTURE, 2015, 75 : 1728 - 1733
  • [27] Experimental evaluation of a solar thermoelectric cooled ceiling combined with displacement ventilation system
    Liu, ZhongBing
    Zhang, Ling
    Gong, GuangCai
    ENERGY CONVERSION AND MANAGEMENT, 2014, 87 : 559 - 565
  • [28] Performance optimization of a sidewall radiant heating system integrated with diffuse ceiling ventilation
    Yang, Bin
    Guo, Yuyao
    Xu, Shuaixing
    Su, Wei
    Wu, Mengchun
    Wang, Faming
    BUILDING AND ENVIRONMENT, 2022, 213
  • [30] Chair Fans or Desk Fans to Aid Performance of Ceiling Personalized Ventilation for Reduced Disease Transmission Between Occupants?
    Habchi, Carine
    Abou Ghali, Kamel
    Ghaddar, Nesreen
    SECOND INTERNATIONAL CONFERENCE ON EFFICIENT BUILDING DESIGN: MATERIALS AND HVAC EQUIPMENT TECHNOLOGIES, 2016, : 115 - 122