Performance Evaluation of Ceiling Mounted Personalized Ventilation System

被引:0
|
作者
Yang, Bin [1 ]
Melikov, Arsen [3 ]
Sekhar, Chandra [2 ]
机构
[1] Natl Univ Singapore, NUS DTU Joint PhD Program, Singapore 117548, Singapore
[2] Natl Univ Singapore, Dept Bldg, Singapore, Singapore
[3] Tech Univ Denmark, Dept Civil Engn, Lyngby, Denmark
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The interaction of the personalized airflow supplied from ceiling mounted nozzle (diameter of 0.095 m (0.312ft)) with the thermal plume generated by a seated thermal manikin with the body size of an average Scandinavian woman and its impact on the body cooling was studied. Experiments were performed in a test room with mixing ventilation at numerous conditions comprising four combinations of room air temperature and personalized air temperature (23.5 degrees C (74.3 F)/21 degrees C (69.8 degrees F), 23.5 degrees C (74.3 degrees F)/23.5 degrees C (74.3 degrees F), 26 degrees C (78.8 degrees F)/ 23.5 degrees C (74.3 degrees F), 26 degrees C (78.8 degrees F)/26 degrees C (78.8 degrees F)), four airflow rates of the personalized air (4 (8.48), 8 (16.95), 12 (25.43), 16 (33.91) L/s (cfm)) and positioning of the manikin directly below the nozzle (I.3m (4.265ft) distance between the top of manikin's head and the nozzle). The asymmetric exposure of the body to the personalized flow was studied by moving the manikin 0.2m (0.656ft) forward, backward and sideward. The blockage effect of the unheated manikin on the personalized airflow distribution, studied at the case 23.5 degrees C (74.3 degrees F)/23.5 degrees C (74.3 degrees F), was clearly observed 0.2m (0.656ft) above the top of manikin's head where the centerline velocity was reduced to about 85% under all personalized airflow rates. The neutral level, X-nl, defined as the distance from the nozzle where the impact of the thermal plume on the velocity distribution in the personalized airflow was observed, increased from 0.8m (2.625ft) to 1.1m (3.609ft) with the increase ofthe airflow rate. Above 16L/s (33.91 cfm) the personalized airflow was able to completely destroy the thermal plume. In comparison with the reference case without personalized airflow, the manikin based equivalent temperature for the head decreased with the increase of the airflow rate from -1 degrees C (-1.8 degrees F) to -6 degrees C (10.8 degrees F) under 23.5 degrees C (74.3 degrees F)/21 degrees C (69.8 degrees F) case and from -0.5 degrees C (-0.9 degrees F) to -4 degrees C (-7.2 degrees F) under 26 degrees C (78.8 degrees F)/26 degrees C (78.8 degrees F) case, which are the two extreme cases among the four cases studied. The personalized airflow was least efficient to cool the body when the manikin was moved forward.
引用
收藏
页码:395 / +
页数:3
相关论文
共 50 条
  • [31] Performance evaluation and comparison of two air terminal devices for personalized ventilation
    Zhou, W
    Tham, KW
    Sun, W
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 436 - 441
  • [32] Performance evaluation of the displacement ventilation combined with evaporative cooled ceiling for a typical office in Beirut
    Younis, Manar
    Ghali, Kamel
    Ghaddar, Nesreen
    ENERGY CONVERSION AND MANAGEMENT, 2015, 105 : 655 - 664
  • [33] Experimental investigation on the ventilation performance of diffuse ceiling ventilation in heating conditions
    Peng, Pei
    Pomianowski, Michal
    Zhang, Chen
    Guo, Rui
    Jensen, Rasmus Lund
    Jonsson, Kim Trangbaek
    Gong, Guangcai
    BUILDING AND ENVIRONMENT, 2021, 205
  • [34] Thermal environment and air quality in office with personalized ventilation combined with chilled ceiling
    Lipczynska, Aleksandra
    Kaczmarczyk, Jan
    Melikov, Arsen K.
    BUILDING AND ENVIRONMENT, 2015, 92 : 603 - 614
  • [35] Performance evaluation of multiagent personalized information system
    Babczynski, T
    Kruczkiewicz, Z
    Magott, J
    ARTIFICIAL INTELLIGENCE AND SOFT COMPUTING - ICAISC 2004, 2004, 3070 : 810 - 815
  • [36] Comparison of chilled ceiling and mixing ventilation assisted by intermittent personalized ventilation: Thermal comfort and energy savings
    Al Assaad D.
    Ghali K.
    Ghaddar N.
    Renewable Energy and Power Quality Journal, 2020, 18 : 431 - 436
  • [37] Performance evaluation of personalized ventilation system with two types of air terminal devices coupled with displacement ventilation in a mock-up office
    Cheong, David K. W.
    Huang, Shuguang
    HVAC&R RESEARCH, 2013, 19 (08): : 974 - 985
  • [38] Performance of personalized ventilation in conjunction with mixing and displacement ventilation
    Cermak, R
    Melikov, AK
    Forejt, L
    Kovar, O
    HVAC&R RESEARCH, 2006, 12 (02): : 295 - 311
  • [39] Performance analysis of a ductless personalized ventilation combined with radiant floor cooling system and displacement ventilation
    Jiying Liu
    Daniel Alejandro Dalgo
    Shengwei Zhu
    Hui Li
    Linhua Zhang
    Jelena Srebric
    Building Simulation, 2019, 12 : 905 - 919
  • [40] Performance analysis of a ductless personalized ventilation combined with radiant floor cooling system and displacement ventilation
    Liu, Jiying
    Dalgo, Daniel Alejandro
    Zhu, Shengwei
    Li, Hui
    Zhang, Linhua
    Srebric, Jelena
    BUILDING SIMULATION, 2019, 12 (05) : 905 - 919