Performance Evaluation of Ceiling Mounted Personalized Ventilation System

被引:0
|
作者
Yang, Bin [1 ]
Melikov, Arsen [3 ]
Sekhar, Chandra [2 ]
机构
[1] Natl Univ Singapore, NUS DTU Joint PhD Program, Singapore 117548, Singapore
[2] Natl Univ Singapore, Dept Bldg, Singapore, Singapore
[3] Tech Univ Denmark, Dept Civil Engn, Lyngby, Denmark
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The interaction of the personalized airflow supplied from ceiling mounted nozzle (diameter of 0.095 m (0.312ft)) with the thermal plume generated by a seated thermal manikin with the body size of an average Scandinavian woman and its impact on the body cooling was studied. Experiments were performed in a test room with mixing ventilation at numerous conditions comprising four combinations of room air temperature and personalized air temperature (23.5 degrees C (74.3 F)/21 degrees C (69.8 degrees F), 23.5 degrees C (74.3 degrees F)/23.5 degrees C (74.3 degrees F), 26 degrees C (78.8 degrees F)/ 23.5 degrees C (74.3 degrees F), 26 degrees C (78.8 degrees F)/26 degrees C (78.8 degrees F)), four airflow rates of the personalized air (4 (8.48), 8 (16.95), 12 (25.43), 16 (33.91) L/s (cfm)) and positioning of the manikin directly below the nozzle (I.3m (4.265ft) distance between the top of manikin's head and the nozzle). The asymmetric exposure of the body to the personalized flow was studied by moving the manikin 0.2m (0.656ft) forward, backward and sideward. The blockage effect of the unheated manikin on the personalized airflow distribution, studied at the case 23.5 degrees C (74.3 degrees F)/23.5 degrees C (74.3 degrees F), was clearly observed 0.2m (0.656ft) above the top of manikin's head where the centerline velocity was reduced to about 85% under all personalized airflow rates. The neutral level, X-nl, defined as the distance from the nozzle where the impact of the thermal plume on the velocity distribution in the personalized airflow was observed, increased from 0.8m (2.625ft) to 1.1m (3.609ft) with the increase ofthe airflow rate. Above 16L/s (33.91 cfm) the personalized airflow was able to completely destroy the thermal plume. In comparison with the reference case without personalized airflow, the manikin based equivalent temperature for the head decreased with the increase of the airflow rate from -1 degrees C (-1.8 degrees F) to -6 degrees C (10.8 degrees F) under 23.5 degrees C (74.3 degrees F)/21 degrees C (69.8 degrees F) case and from -0.5 degrees C (-0.9 degrees F) to -4 degrees C (-7.2 degrees F) under 26 degrees C (78.8 degrees F)/26 degrees C (78.8 degrees F) case, which are the two extreme cases among the four cases studied. The personalized airflow was least efficient to cool the body when the manikin was moved forward.
引用
收藏
页码:395 / +
页数:3
相关论文
共 50 条
  • [1] OCCUPANT MOVEMENT ANALYSIS OF CEILING MOUNTED PERSONALIZED VENTILATION SYSTEM
    Yang, Bin
    Melikov, Arsen K.
    Sekhar, Chandra S.
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 370 - 375
  • [2] Interaction of dynamic indoor environment with moving person and performance of ceiling mounted personalized ventilation system
    Yang, Bin
    Sekhar, Chandra
    INDOOR AND BUILT ENVIRONMENT, 2014, 23 (07) : 920 - 932
  • [3] SUBJECTIVE ASSESSMENTS OF THERMAL SENSATION FOR CEILING MOUNTED PERSONALIZED VENTILATION SYSTEM
    Yang, Bin
    Sekhar, Chandra S.
    Melikov, Arsen K.
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 401 - 408
  • [4] Ceiling mounted personalized ventilation system in hot and humid climate-An energy analysis
    Yang, Bin
    Sekhar, Chandra
    Melikov, Arsen K.
    ENERGY AND BUILDINGS, 2010, 42 (12) : 2304 - 2308
  • [5] Investigating the Performance of Ceiling Mounted Personalized Ventilation System Assisted by Chair Fans: Assessment of Thermal Comfort and Indoor Air Quality
    El Fil, Bachir
    Ghaddar, Nesreen
    Ghali, Kamel
    SECOND INTERNATIONAL CONFERENCE ON EFFICIENT BUILDING DESIGN: MATERIALS AND HVAC EQUIPMENT TECHNOLOGIES, 2016, : 138 - 145
  • [6] The Influence of Evenly Distributed Ceiling Mounted Personalized Ventilation Devices on the Indoor Environment
    Bin, Yang
    Sekhar, S. C.
    INTERNATIONAL JOURNAL OF VENTILATION, 2008, 7 (02) : 99 - 112
  • [7] Optimizing performance of ceiling-mounted personalized ventilation system assisted by chair fans: Assessment of thermal comfort and indoor air quality
    El-Fil, Bachir
    Ghaddar, Nesreen
    Ghali, Kamel
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (04) : 412 - 430
  • [8] Thermal comfort and energy performance of a low-mixing ceiling-mounted personalized ventilator system
    Makhoul, A.
    Ghali, K.
    Ghaddar, N.
    BUILDING AND ENVIRONMENT, 2013, 60 : 126 - 136
  • [9] Desk fans for the control of the convection flow around occupants using ceiling mounted personalized ventilation
    Makhoul, A.
    Ghali, K.
    Ghaddar, N.
    BUILDING AND ENVIRONMENT, 2013, 59 : 336 - 348
  • [10] Ceiling-mounted personalized ventilation system integrated with a secondary air distribution system - a human response study in hot and humid climate
    Yang, B.
    Sekhar, S. C.
    Melikov, A. K.
    INDOOR AIR, 2010, 20 (04) : 309 - 319