Locking Plates With Computationally Enhanced Screw Trajectories Provide Superior Biomechanical Fixation Stability of Complex Proximal Humerus Fractures

被引:4
|
作者
Mischler, Dominic [1 ]
Schader, Jana Felicitas [1 ]
Dauwe, Jan [1 ,2 ]
Tenisch, Lara [1 ]
Gueorguiev, Boyko [1 ]
Windolf, Markus [1 ]
Varga, Peter [1 ]
机构
[1] AO Res Inst Davos, Davos, Switzerland
[2] UZ Leuven, Dept Trauma Surg, Leuven, Belgium
关键词
bone fracture (MeSH ID; D050723); osteosynthesis; implant optimization; 3D-printing; finite element analysis; fixation failure; ANGULAR STABLE PLATE; NONOPERATIVE TREATMENT; INTERNAL-FIXATION; ELDERLY-PATIENTS; PERFORATION; STIFFNESS; SYSTEMS; ADULTS; LOAD;
D O I
10.3389/fbioe.2022.919721
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Joint-preserving surgical treatment of complex unstable proximal humerus fractures remains challenging, with high failure rates even following state-of-the-art locked plating. Enhancement of implants could help improve outcomes. By overcoming limitations of conventional biomechanical testing, finite element (FE) analysis enables design optimization but requires stringent validation. This study aimed to computationally enhance the design of an existing locking plate to provide superior fixation stability and evaluate the benefit experimentally in a matched-pair fashion. Further aims were the evaluation of instrumentation accuracy and its potential influence on the specimen-specific predictive ability of FE. Screw trajectories of an existing commercial plate were adjusted to reduce the predicted cyclic cut-out failure risk and define the enhanced (EH) implant design based on results of a previous parametric FE study using 19 left proximal humerus models (Set A). Superiority of EH versus the original (OG) design was tested using nine pairs of human proximal humeri (N = 18, Set B). Specimen-specific CT-based virtual preoperative planning defined osteotomies replicating a complex 3-part fracture and fixation with a locking plate using six screws. Bone specimens were prepared, osteotomized and instrumented according to the preoperative plan via a standardized procedure utilizing 3D-printed guides. Cut-out failure of OG and EH implant designs was compared in paired groups with both FE analysis and cyclic biomechanical testing. The computationally enhanced implant configuration achieved significantly more cycles to cut-out failure compared to the standard OG design (p < 0.01), confirming the significantly lower peri-implant bone strain predicted by FE for the EH versus OG groups (p < 0.001). The magnitude of instrumentation inaccuracies was small but had a significant effect on the predicted failure risk (p < 0.01). The sample-specific FE predictions strongly correlated with the experimental results (R-2 = 0.70) when incorporating instrumentation inaccuracies. These findings demonstrate the power and validity of FE simulations in improving implant designs towards superior fixation stability of proximal humerus fractures. Computational optimization could be performed involving further implant features and help decrease failure rates. The results underline the importance of accurate surgical execution of implant fixations and the need for high consistency in validation studies.
引用
收藏
页数:11
相关论文
共 47 条
  • [31] Optimization of Locking Plate Screw Angle Used to Treat Two-Part Proximal Humerus Fractures to Maintain Fracture Stability
    Castro-Franco, Angel D.
    Mendoza-Munoz, Ismael
    Gonzalez-Angeles, Alvaro
    Montoya-Reyes, Mildrend I.
    Pitalua-Diaz, Nun
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [32] Biomechanical evaluation of the stability of extra-articular distal radius fractures fixed with volar locking plates according to the length of the distal locking screw
    Oh, Gyung-Hwan
    Kim, Hak-Sung
    Lee, Jung Il
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (08) : 922 - 932
  • [33] Dynamic biomechanical investigation of a novel sulcus bicipitalis plate in combination with a conventional locking plate for the treatment of complex proximal humerus fractures
    Wendler, Toni
    Fischer, Benjamin
    Schleifenbaum, Stefan
    Theopold, Jan
    Hepp, Pierre
    CLINICAL BIOMECHANICS, 2023, 105
  • [34] Primary screw perforation or subsequent screw cut-out following proximal humerus fracture fixation using locking plates: a review of causative factors and proposed solutions
    McMillan, Tristan E.
    Johnstone, Alan J.
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (08) : 1935 - 1942
  • [35] Primary screw perforation or subsequent screw cut-out following proximal humerus fracture fixation using locking plates: a review of causative factors and proposed solutions
    Tristan E. McMillan
    Alan J. Johnstone
    International Orthopaedics, 2018, 42 : 1935 - 1942
  • [36] Two reconstruction plates provide superior stability of displaced midshaft clavicle fractures in comparison to single plating - A biomechanical study
    Yanev, Parvan
    Zderic, Ivan
    Pukalski, Yavor
    Enchev, Dian
    Rashkov, Mihail
    Varga, Peter
    Gehweiler, Dominic
    Richards, Geoff
    Gueorguiev, Boyko
    Baltov, Asen
    CLINICAL BIOMECHANICS, 2020, 80
  • [37] Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures
    Vigdorchik, Jonathan M.
    Esquivel, Amanda O.
    Jin, Xin
    Yang, King H.
    Onwudiwe, Ndidi A.
    Vaidya, Rahul
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2012, 7
  • [38] Biomechanical stability of a supra-acetabular pedicle screw Internal Fixation device (INFIX) vs External Fixation and plates for vertically unstable pelvic fractures
    Jonathan M Vigdorchik
    Amanda O Esquivel
    Xin Jin
    King H Yang
    Ndidi A Onwudiwe
    Rahul Vaidya
    Journal of Orthopaedic Surgery and Research, 7
  • [39] Focus on stability: biomechanical evaluation of external fixation technique versus locking plate osteosynthesis in 3-part proximal humeral fractures
    Harbrecht, Andreas
    Hackl, Michael
    Leschinger, Tim
    Mueller, Lars P.
    Wegmann, Kilian
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (08) : 1666 - 1673
  • [40] Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: a finite element analysis
    Yang, Pan
    Zhang, Ying
    Liu, Jian
    Xiao, Jin
    Ma, Li Min
    Zhu, Chang Rong
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2015, 49 (02) : 203 - 209