Dynamic biomechanical investigation of a novel sulcus bicipitalis plate in combination with a conventional locking plate for the treatment of complex proximal humerus fractures

被引:1
|
作者
Wendler, Toni [1 ,2 ,4 ]
Fischer, Benjamin [1 ,2 ]
Schleifenbaum, Stefan [1 ,3 ]
Theopold, Jan [3 ]
Hepp, Pierre [1 ,3 ]
机构
[1] Univ Leipzig, Ctr Res Musculoskeletal Syst, ZESBO, Leipzig, Germany
[2] Univ Leipzig, Inst Anat, Leipzig, Germany
[3] Univ Leipzig, Dept Orthopaed Trauma & Plast Surg, Leipzig, Germany
[4] Univ Leipzig, Ctr Res Musculoskeletal Syst, ZESBO, Semmelweisstr 14, D-04103 Leipzig, Germany
关键词
Proximal humerus fracture; Double-plate osteosynthesis; Sulcus bicipitalis; Biomechanical investigation; ANGULAR STABLE PLATE; MEDIAL SUPPORT; FIXATION; SCREWS;
D O I
10.1016/j.clinbiomech.2023.105984
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Complex proximal humerus fractures place high demands on osteosynthetic treatment. In some cases, double plating has already been used to increase primary stability of the osteosynthesis. This approach was advanced in the present study by developing an additive plate for the sulcus bicipitalis. To demonstrate the superior primary stability of the newly developed plate osteosynthesis, a biomechanical comparison against a conventional locking plate with an additional calcar screw was performed. Methods: Ten pairs of cadaveric humeri were treated proximally with a locking plate (PENTA plate small frag-ment, INTERCUS). Each had a two-part fracture model with a fracture gap of 10 mm. All right humeri were treated with an additive novel plate that extends along the bicipital sulcus and encircles the lesser tuberosity proximally. First, the specimens were loaded sinusoidally at 250 N in 20 degrees abduction for 5000 cycles. Afterwards quasi-static loading until failure was applied.Findings: The movement at the fracture gap due to the cyclic loading occurred mainly as rotation around the z-axis, corresponding to a tilt medially and distally. The double plate osteosynthesis reduces the rotation by approximately 39%. For all load cycles observed, except 5000 cycles, medial and distal rotation of the head was significantly reduced by the double plate. The failure loads showed no significant differences between the groups.Interpretation: In the tested scenario under cyclic loading, the novel double plate osteosynthesis showed a sig-nificant superiority of primary stability over the conventional treatment with one locking plate. Furthermore, the study showed the advantages of cyclic load application over quasi-static load application until failure.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Biomechanical analysis of a novel locking plate with smooth pegs versus a conventional locking plate with threaded screws for proximal humerus fractures
    Yamamoto, Nobuyuki
    Hongo, Michio
    Berglund, Lawrence J.
    Sperling, John W.
    Cofield, Robert H.
    An, Kai-Nan
    Steinmann, Scott P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (04) : 445 - 450
  • [2] A biomechanical comparison of locking plate and locking nail implants used for fractures of the proximal humerus
    Kitson, Jeffrey
    Booth, Grant
    Day, Robert
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (03) : 362 - 366
  • [3] Locking Plate Fixation of Proximal Humerus Fractures
    Strohm, Peter C.
    Koestler, Wolfgang
    Suedkamp, Norbert P.
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2005, 6 (01): : 8 - 13
  • [4] Locking Plate Fixation for Proximal Humerus Fractures
    Burke, Neil G.
    Kennedy, Jim
    Green, Connor
    Dodds, Michael K.
    Mullett, Hannan
    ORTHOPEDICS, 2012, 35 (02) : E250 - E254
  • [5] Locking plate osteosynthesis for fractures of the proximal humerus
    Lungershausen, W
    Bach, O
    Lorenz, CO
    ZENTRALBLATT FUR CHIRURGIE, 2003, 128 (01): : 28 - 33
  • [6] BIOMECHANICAL COMPARISON OF THE ROLE OF INLAY GRAFT IN PROXIMAL HUMERUS FRACTURE FIXED WITH CONVENTIONAL PLATE AND LOCKING PLATE
    Lee, Cheng-Hung
    Huang, Kui-Chou
    Hsiao, Chih-Kun
    Cheng, Sung
    Liu, Yau-Chia
    Chang, Chih-Han
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2013, 13 (04)
  • [7] Functional outcomes of locking plate fixation in complex proximal humerus fractures
    Shaikh, Saeed Ahmed
    Arain, Muhammad Arif
    Rehman, Muhammad Mansoor
    Ahmed, Nadeem
    Samejo, Muhammad Qasim Ali
    RAWAL MEDICAL JOURNAL, 2020, 45 (03): : 633 - 636
  • [8] Early results of treatment of proximal humerus fractures with the PHILOS locking plate
    Kilic, Buelent
    Uysal, Mustafa
    Cinar, Bekir Murat
    Oezkoc, Guerkan
    Demiroers, Hueseyin
    Akpinar, Sercan
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2008, 42 (03) : 149 - 153
  • [9] TREATMENT OF PROXIMAL HUMERUS FRACTURES WITH LOCKING COMPRESSION PLATE - A PROSPECTIVE STUDY
    Anvekar, Praveen M.
    Sachin, N. S.
    Nelivigi, Anil S.
    Rao, Venkataramana
    Manjunath, J.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2013, 2 (40): : 7728 - 7738
  • [10] Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
    Jabran, Ali
    Peach, Chris
    Zou, Zhenmin
    Ren, Lei
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17