Dynamic biomechanical investigation of a novel sulcus bicipitalis plate in combination with a conventional locking plate for the treatment of complex proximal humerus fractures

被引:1
|
作者
Wendler, Toni [1 ,2 ,4 ]
Fischer, Benjamin [1 ,2 ]
Schleifenbaum, Stefan [1 ,3 ]
Theopold, Jan [3 ]
Hepp, Pierre [1 ,3 ]
机构
[1] Univ Leipzig, Ctr Res Musculoskeletal Syst, ZESBO, Leipzig, Germany
[2] Univ Leipzig, Inst Anat, Leipzig, Germany
[3] Univ Leipzig, Dept Orthopaed Trauma & Plast Surg, Leipzig, Germany
[4] Univ Leipzig, Ctr Res Musculoskeletal Syst, ZESBO, Semmelweisstr 14, D-04103 Leipzig, Germany
关键词
Proximal humerus fracture; Double-plate osteosynthesis; Sulcus bicipitalis; Biomechanical investigation; ANGULAR STABLE PLATE; MEDIAL SUPPORT; FIXATION; SCREWS;
D O I
10.1016/j.clinbiomech.2023.105984
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Complex proximal humerus fractures place high demands on osteosynthetic treatment. In some cases, double plating has already been used to increase primary stability of the osteosynthesis. This approach was advanced in the present study by developing an additive plate for the sulcus bicipitalis. To demonstrate the superior primary stability of the newly developed plate osteosynthesis, a biomechanical comparison against a conventional locking plate with an additional calcar screw was performed. Methods: Ten pairs of cadaveric humeri were treated proximally with a locking plate (PENTA plate small frag-ment, INTERCUS). Each had a two-part fracture model with a fracture gap of 10 mm. All right humeri were treated with an additive novel plate that extends along the bicipital sulcus and encircles the lesser tuberosity proximally. First, the specimens were loaded sinusoidally at 250 N in 20 degrees abduction for 5000 cycles. Afterwards quasi-static loading until failure was applied.Findings: The movement at the fracture gap due to the cyclic loading occurred mainly as rotation around the z-axis, corresponding to a tilt medially and distally. The double plate osteosynthesis reduces the rotation by approximately 39%. For all load cycles observed, except 5000 cycles, medial and distal rotation of the head was significantly reduced by the double plate. The failure loads showed no significant differences between the groups.Interpretation: In the tested scenario under cyclic loading, the novel double plate osteosynthesis showed a sig-nificant superiority of primary stability over the conventional treatment with one locking plate. Furthermore, the study showed the advantages of cyclic load application over quasi-static load application until failure.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Complications after Locking Plate Fixation of Fractures of the Proximal Humerus
    Gerber, Christian
    Spross, Christian
    Gren, Holger
    Jost, Bernhard
    SWISS MEDICAL WEEKLY, 2011, 141 : 29S - 29S
  • [22] A systematic review of locking plate fixation of proximal humerus fractures
    Sproul, Robert C.
    Iyengar, Jaicharan J.
    Devcic, Zlatko
    Feeley, Brian T.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2011, 42 (04): : 408 - 413
  • [23] Current concepts in locking plate fixation of proximal humerus fractures
    Laux, Christoph J.
    Grubhofer, Florian
    Werner, Clement M. L.
    Simmen, Hans-Peter
    Osterhoff, Georg
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [24] Biomechanical analysis of plate osteosynthesis systems for proximal humerus fractures
    Lever, James P.
    Aksenov, Sergei A.
    Zdero, Rad
    Ahn, Henry
    Mckee, Michael D.
    Schemitsch, Emil H.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (01) : 23 - 29
  • [25] Treatment of complex proximal femoral fractures with the proximal femur locking compression plate
    Hasenboehler, Erik A.
    Agudelo, Juan F.
    Morgan, Steven J.
    Smith, Wade R.
    Hak, David J.
    Stahel, Philip F.
    ORTHOPEDICS, 2007, 30 (08) : 618 - 623
  • [26] Functional Outcome and Complications in Management of Proximal Humerus Fractures Operated with Proximal Humerus Locking Plate
    George, P. K.
    Dasgupta, B.
    Bhaladhare, S. M.
    Reddy, B. P., V
    Jain, A.
    Jogani, A. D.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2021, 15 (02) : 47 - 54
  • [27] The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus
    Bae, J. -H.
    Oh, J. -K.
    Chon, C. -S.
    Oh, C. -W.
    Hwang, J. -H.
    Yoon, Y. -C.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (07): : 937 - 941
  • [28] Clinical efficacy of locking plate combined with suture anchors for the treatment of proximal humerus fractures
    Li, Yiping
    Wu, Zonghong
    Yang, Jinsong
    Zheng, Jinwen
    Xiang, Ming
    MINERVA SURGERY, 2024,
  • [29] Comparison of locking plate and conservative treatment in elderly patients with displaced proximal humerus fractures
    Uğur Bezirgan
    Malik Kısmet
    Yusuf Kıratlıoğlu
    Mehmet Yalçın
    Mehmet Armangil
    International Orthopaedics, 2025, 49 (3) : 737 - 745
  • [30] Complications encountered in proximal humerus fractures treated with locking plate fixation
    Aksu, Neslihan
    Gogus, Abdullah
    Kara, Ayhan Nedim
    Isiklar, Zekeriya Ugur
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2010, 44 (02) : 89 - 96