Dynamic biomechanical investigation of a novel sulcus bicipitalis plate in combination with a conventional locking plate for the treatment of complex proximal humerus fractures

被引:1
|
作者
Wendler, Toni [1 ,2 ,4 ]
Fischer, Benjamin [1 ,2 ]
Schleifenbaum, Stefan [1 ,3 ]
Theopold, Jan [3 ]
Hepp, Pierre [1 ,3 ]
机构
[1] Univ Leipzig, Ctr Res Musculoskeletal Syst, ZESBO, Leipzig, Germany
[2] Univ Leipzig, Inst Anat, Leipzig, Germany
[3] Univ Leipzig, Dept Orthopaed Trauma & Plast Surg, Leipzig, Germany
[4] Univ Leipzig, Ctr Res Musculoskeletal Syst, ZESBO, Semmelweisstr 14, D-04103 Leipzig, Germany
关键词
Proximal humerus fracture; Double-plate osteosynthesis; Sulcus bicipitalis; Biomechanical investigation; ANGULAR STABLE PLATE; MEDIAL SUPPORT; FIXATION; SCREWS;
D O I
10.1016/j.clinbiomech.2023.105984
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Complex proximal humerus fractures place high demands on osteosynthetic treatment. In some cases, double plating has already been used to increase primary stability of the osteosynthesis. This approach was advanced in the present study by developing an additive plate for the sulcus bicipitalis. To demonstrate the superior primary stability of the newly developed plate osteosynthesis, a biomechanical comparison against a conventional locking plate with an additional calcar screw was performed. Methods: Ten pairs of cadaveric humeri were treated proximally with a locking plate (PENTA plate small frag-ment, INTERCUS). Each had a two-part fracture model with a fracture gap of 10 mm. All right humeri were treated with an additive novel plate that extends along the bicipital sulcus and encircles the lesser tuberosity proximally. First, the specimens were loaded sinusoidally at 250 N in 20 degrees abduction for 5000 cycles. Afterwards quasi-static loading until failure was applied.Findings: The movement at the fracture gap due to the cyclic loading occurred mainly as rotation around the z-axis, corresponding to a tilt medially and distally. The double plate osteosynthesis reduces the rotation by approximately 39%. For all load cycles observed, except 5000 cycles, medial and distal rotation of the head was significantly reduced by the double plate. The failure loads showed no significant differences between the groups.Interpretation: In the tested scenario under cyclic loading, the novel double plate osteosynthesis showed a sig-nificant superiority of primary stability over the conventional treatment with one locking plate. Furthermore, the study showed the advantages of cyclic load application over quasi-static load application until failure.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Open reduction and locking plate fixation of displaced proximal humerus fractures
    Kumar, Chandan
    Gupta, Anil Kumar
    Nath, Rohit
    Ahmad, Javed
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (02) : 156 - 160
  • [32] Open reduction and locking plate fixation of displaced proximal humerus fractures
    Chandan Kumar
    Anil Kumar Gupta
    Rohit Nath
    Javed Ahmad
    Indian Journal of Orthopaedics, 2013, 47 : 156 - 160
  • [33] Adult proximal humerus locking plate for fixation of paediatric subtrochanteric fractures
    Gogna P.
    Mohindra M.
    Verma S.
    Thora A.
    Tiwari A.
    Singla R.
    MUSCULOSKELETAL SURGERY, 2014, 98 (3) : 189 - 194
  • [34] Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus
    Matassi, Fabrizio
    Angeloni, Renzo
    Carulli, Christian
    Civinini, Roberto
    Di Bella, Leonardo
    Redl, Birgit
    Innocenti, Massimo
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (11): : 1939 - 1942
  • [35] Complex fractures of the proximal humerus in the elderly-outcome and complications after locking plate fixation
    Schliemann B.
    Siemoneit J.
    Theisen Ch.
    Kösters C.
    Weimann A.
    Raschke M.J.
    MUSCULOSKELETAL SURGERY, 2012, 96 (Suppl 1) : S3 - S11
  • [36] Treatment of three- and four-part proximal humeral fractures with locking proximal humerus plate
    Sun J.-C.
    Li Y.-L.
    Ning G.-Z.
    Wu Q.
    Feng S.-Q.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (6) : 699 - 704
  • [37] Die winkelstabile Plattenosteosynthese bei Frakturen am proximalen Humerus mit der LPHP (Locking Proximal Humerus Plate)Internal Fixation of Proximal Humerus Fractures Using the Locking Proximal Humerus Plate
    Michael Plecko
    Aurel Kraus
    Operative Orthopädie und Traumatologie, 2005, 17 (1) : 25 - 50
  • [38] Treatment of proximal humerus fractures with a CFR-PEEK plate: 2-year results of a prospective study and comparison to fixation with a conventional locking plate
    Schliemann, Benedikt
    Hartensuer, Rene
    Koch, Thorben
    Theisen, Christina
    Raschke, Michael J.
    Koesters, Clemens
    Weimann, Andre
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (08) : 1282 - 1288
  • [39] Pathological fractures of the proximal humerus treated with a proximal humeral locking plate and bone cement
    Siegel, H. J.
    Lopez-Ben, R.
    Mann, J. P.
    Ponce, B. A.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (05): : 707 - 712
  • [40] How to enhance the stability of locking plate fixation of proximal humerus fractures? An overview of current biomechanical and clinical data
    Schliemann, Benedikt
    Waehnert, Dirk
    Theisen, Christina
    Herbort, Mirco
    Koesters, Clemens
    Raschke, Michael J.
    Weimann, Andre
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (07): : 1207 - 1214