Locking Plates With Computationally Enhanced Screw Trajectories Provide Superior Biomechanical Fixation Stability of Complex Proximal Humerus Fractures

被引:4
|
作者
Mischler, Dominic [1 ]
Schader, Jana Felicitas [1 ]
Dauwe, Jan [1 ,2 ]
Tenisch, Lara [1 ]
Gueorguiev, Boyko [1 ]
Windolf, Markus [1 ]
Varga, Peter [1 ]
机构
[1] AO Res Inst Davos, Davos, Switzerland
[2] UZ Leuven, Dept Trauma Surg, Leuven, Belgium
关键词
bone fracture (MeSH ID; D050723); osteosynthesis; implant optimization; 3D-printing; finite element analysis; fixation failure; ANGULAR STABLE PLATE; NONOPERATIVE TREATMENT; INTERNAL-FIXATION; ELDERLY-PATIENTS; PERFORATION; STIFFNESS; SYSTEMS; ADULTS; LOAD;
D O I
10.3389/fbioe.2022.919721
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Joint-preserving surgical treatment of complex unstable proximal humerus fractures remains challenging, with high failure rates even following state-of-the-art locked plating. Enhancement of implants could help improve outcomes. By overcoming limitations of conventional biomechanical testing, finite element (FE) analysis enables design optimization but requires stringent validation. This study aimed to computationally enhance the design of an existing locking plate to provide superior fixation stability and evaluate the benefit experimentally in a matched-pair fashion. Further aims were the evaluation of instrumentation accuracy and its potential influence on the specimen-specific predictive ability of FE. Screw trajectories of an existing commercial plate were adjusted to reduce the predicted cyclic cut-out failure risk and define the enhanced (EH) implant design based on results of a previous parametric FE study using 19 left proximal humerus models (Set A). Superiority of EH versus the original (OG) design was tested using nine pairs of human proximal humeri (N = 18, Set B). Specimen-specific CT-based virtual preoperative planning defined osteotomies replicating a complex 3-part fracture and fixation with a locking plate using six screws. Bone specimens were prepared, osteotomized and instrumented according to the preoperative plan via a standardized procedure utilizing 3D-printed guides. Cut-out failure of OG and EH implant designs was compared in paired groups with both FE analysis and cyclic biomechanical testing. The computationally enhanced implant configuration achieved significantly more cycles to cut-out failure compared to the standard OG design (p < 0.01), confirming the significantly lower peri-implant bone strain predicted by FE for the EH versus OG groups (p < 0.001). The magnitude of instrumentation inaccuracies was small but had a significant effect on the predicted failure risk (p < 0.01). The sample-specific FE predictions strongly correlated with the experimental results (R-2 = 0.70) when incorporating instrumentation inaccuracies. These findings demonstrate the power and validity of FE simulations in improving implant designs towards superior fixation stability of proximal humerus fractures. Computational optimization could be performed involving further implant features and help decrease failure rates. The results underline the importance of accurate surgical execution of implant fixations and the need for high consistency in validation studies.
引用
收藏
页数:11
相关论文
共 47 条
  • [21] Locking screw-plate interface stability in carbon-fibre reinforced polyetheretherketone proximal humerus plates
    David J. Hak
    Ryan Fader
    Todd Baldini
    Vivek B. S. Chadayammuri
    International Orthopaedics, 2017, 41 : 1735 - 1739
  • [22] Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model
    Walsh, Stephen
    Reindl, Rudy
    Harvey, Edward
    Berry, Gregory
    Beckman, Lorne
    Steffen, Thomas
    CLINICAL BIOMECHANICS, 2006, 21 (10) : 1027 - 1031
  • [23] The biomechanical performance of locking plate fixation with intramedullary fibular strut graft augmentation in the treatment of unstable fractures of the proximal humerus
    Bae, J. -H.
    Oh, J. -K.
    Chon, C. -S.
    Oh, C. -W.
    Hwang, J. -H.
    Yoon, Y. -C.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (07): : 937 - 941
  • [24] Complex Distal Humerus Fractures-Comparison of Polyaxial Locking and Nonlocking Screw Configurations-A Preliminary Biomechanical Study
    Hungerer, Sven
    Wipf, Felix
    von Oldenburg, Geert
    Augat, Peter
    Penzkofer, Rainer
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (03) : 130 - 136
  • [25] Biomechanical effect of the configuration of screw hole style on locking plate fixation in proximal humerus fracture with a simulated gap: A finite element analysis
    Zhang, Ya-Kui
    Wei, Hung-Wen
    Lin, Kang-Ping
    Chen, Wen-Chuan
    Tsai, Cheng-Lun
    Lin, Kun-Jhih
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (06): : 1191 - 1195
  • [26] Minimally invasive plate osteosynthesis with a locking compression plate is superior to open reduction and internal fixation in the management of the proximal humerus fractures
    Tao Lin
    Baojun Xiao
    Xiucai Ma
    Dehao Fu
    Shuhua Yang
    BMC Musculoskeletal Disorders, 15
  • [27] Minimally invasive plate osteosynthesis with a locking compression plate is superior to open reduction and internal fixation in the management of the proximal humerus fractures
    Lin, Tao
    Xiao, Baojun
    Ma, Xiucai
    Fu, Dehao
    Yang, Shuhua
    BMC MUSCULOSKELETAL DISORDERS, 2014, 15
  • [28] Is intramedullary screw fixation biomechanically superior to locking plate fixation and/or tension band wiring in transverse olecranon fractures? A cadaveric biomechanical comparison study
    Hahn, Alexander
    O'Hara, Nathan N.
    Koh, Kyung
    Zhang, Li-Qun
    O'Toole, Robert, V
    Eglseder, W. Andrew
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (04): : 850 - 855
  • [29] Stability of radial head and neck fractures: A biomechanical study of six fixation constructs with consideration of three locking plates
    Burkhart, Klaus Josef
    Mueller, Lars P.
    Krezdorn, David
    Appelmann, Philipp
    Prommersberger, Karl J.
    Sternstein, Werner
    Rommens, Pol M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2007, 32A (10): : 1569 - 1575
  • [30] Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures
    Schliemann, Benedikt
    Seifert, Robert
    Rosslenbroich, Steffen B.
    Theisen, Christina
    Waehnert, Dirk
    Raschke, Michael J.
    Weimann, Andre
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2015, 24 (12) : 1968 - 1973