A new non-invasive device for measuring instantaneous blood pressure in radial artery based on the volume-compensation method

被引:2
|
作者
Tanaka, S [1 ]
Gao, S [1 ]
Nogawa, M [1 ]
Yamakoshi, K [1 ]
机构
[1] Kanazawa Univ, Fac Engn, Kanazawa, Ishikawa 920, Japan
关键词
blood pressure; non-invasive measurement; radial artery; volume-compensation method;
D O I
10.1109/IEMBS.2003.1280810
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A prototype system for non-invasively measure instantaneous blood pressure (BP) in radial artery was newly devised. The system was based on the volume-compensation method, and several components were newly designed, i.e., a disk-type cuff for local pressurization and a nozzle-flapper type electro-pneumatic converter (EPC) for the cuff-pressure control. Results of experiments indicated that, using the disk-type cuff, the radial artery could be completely compressed, and newly devised EPC had sufficient frequency response for BP measurement in human. Also indicated was that the prototype system consisted with these component was capable of non-invasively measuring instantaneous blood pressure in radial artery, not only in rest condition, but also in a stressful condition such as cold pressor test.
引用
收藏
页码:3149 / 3152
页数:4
相关论文
共 50 条
  • [21] Method and device for non-invasive blood glucose measurement
    Amerov, AK
    Jeon, KJ
    Kim, YJ
    Yoon, G
    OPTICAL DIAGNOSTICS OF BIOLOGICAL FLUIDS IV, PROCEEDINGS OF, 1999, 3599 : 33 - 42
  • [22] On measuring the instantaneous blood pressure in an artery via the tissue control method
    Lin, Albert Chin-Yuh
    Huang, Huang-Nan
    Su, Yi-Chang
    Shiu, Chih-Yuan
    Wang, Yao-Horng
    Chiang, Hao-Cheng
    Tung, Hung
    Lin, Jui-Shan
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (08) : 937 - 951
  • [23] NEW NON-INVASIVE BEDSIDE METHOD FOR MEASURING PULMONARY BLOOD-FLOW
    GEDEON, A
    CRITICAL CARE MEDICINE, 1979, 7 (03) : 137 - 137
  • [24] Non-invasive blood pressure measurement based on the electronic palpation method
    Nissilä, S
    Sorvisto, M
    Sorvoja, H
    Vieri-Gashi, E
    Myllylä, R
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1723 - 1726
  • [25] Variations in Non-invasive Radial Artery Pulse Waveform at Different Measuring Positions
    Lee, Jeon
    Jeon, Young-Ju
    Lee, Hae-Jung
    Kim, Jong-Yeol
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1415 - +
  • [26] A non-invasive continuous method of measuring blood volume during haemodialysis using optical techniques
    McMahon, MP
    Campbell, SB
    Shannon, GF
    Wilkinson, JS
    Fleming, SJ
    MEDICAL ENGINEERING & PHYSICS, 1996, 18 (02) : 105 - 109
  • [27] Non-invasive method for the aortic blood pressure waveform estimation using the measured radial EBI
    Krivoshei, Andrei
    Lamp, Juergen
    Min, Mart
    Uuetoa, Tiina
    Uuetoa, Hasso
    Annus, Paul
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [28] Calibration accuracy of hospital-based non-invasive blood pressure measuring devices
    A de Greeff
    I Lorde
    A Wilton
    P Seed
    A J Coleman
    A H Shennan
    Journal of Human Hypertension, 2010, 24 : 58 - 63
  • [29] NON-INVASIVE METHOD FOR MEASURING CENTRAL VENOUS-PRESSURE
    DURR, JA
    SIMON, CA
    VALLOTTON, MB
    KRAHENBUHL, B
    LANCET, 1978, 1 (8064): : 586 - 587
  • [30] Calibration accuracy of hospital-based non-invasive blood pressure measuring devices
    de Greeff, A.
    Lorde, I.
    Wilton, A.
    Seed, P.
    Coleman, A. J.
    Shennan, A. H.