Calibration accuracy of hospital-based non-invasive blood pressure measuring devices

被引:0
|
作者
A de Greeff
I Lorde
A Wilton
P Seed
A J Coleman
A H Shennan
机构
[1] Maternal and Fetal Research Unit,Division of Reproduction and Endocrinology
[2] King’s College London,Medical Physics Department
[3] Guy’s and St Thomas’ NHS Foundation Trust,undefined
来源
关键词
calibration; blood pressure measurement; device; accuracy; non-invasive;
D O I
暂无
中图分类号
学科分类号
摘要
Accurate blood pressure (BP) measurement is dependent on a trained observer using validated and properly maintained equipment. BP devices should be checked regularly to ensure that their calibration remains within the European Standard specification of ±3 mm Hg. This study assessed the air leakage rates and calibration accuracy of BP devices in use at a large teaching hospital, using a calibrated electronic pressure gauge as reference. Air leakage rates were recorded over 1 min and static pressures were recorded at 250/200/150/100/50/0 mm Hg for computer download and analysis. A total of 127 devices were assessed (18 mercury, 62 aneroid and 47 automated). In total, 22 different models of devices were available, of which 11 were automated and only 4 had published evidence of a validation using a recognized protocol (British Hypertension Society, Association for the Advancement of Medical Instrumentation or International Protocol). Only 3% (n=4) of devices had an air leakage rate within 4 mm Hg per min and 25% (n=32) of devices failed to meet the European calibration standard of ±3 mm Hg. Respective failure rates were 6% (1/18) for mercury, 31% (19/62) for aneroid and 26% (12/47) for automated devices. Inaccurate BP measurement of only 3 mm Hg can have detrimental effects in the patient. This study shows a quarter of devices currently in use at a large teaching hospital to have an unacceptable calibration error. Regular maintenance and calibration checks are vital in ensuring that BP is measured as accurately as possible.
引用
收藏
页码:58 / 63
页数:5
相关论文
共 50 条
  • [1] Calibration accuracy of hospital-based non-invasive blood pressure measuring devices
    de Greeff, A.
    Lorde, I.
    Wilton, A.
    Seed, P.
    Coleman, A. J.
    Shennan, A. H.
    [J]. JOURNAL OF HUMAN HYPERTENSION, 2010, 24 (01) : 58 - 63
  • [2] Calibration of oscillometric non-invasive devices for monitoring blood pressure
    Doh, Il
    Lim, Hyun Kyoon
    Ahn, Bongyoung
    [J]. METROLOGIA, 2015, 52 (02) : 291 - 296
  • [3] Calibration accuracy of hospital based automated blood pressure devices.
    Hoffmann, A.
    Lorde, I
    Shennan, A. H.
    [J]. HYPERTENSION IN PREGNANCY, 2006, 25 : 164 - 164
  • [4] Measuring non-invasive blood pressure in obese patients
    Weeratunga, GU
    [J]. ANAESTHESIA, 2003, 58 (06) : 616 - 616
  • [5] THE NEED FOR A STANDARDIZED PROTOCOL FOR VALIDATING NON-INVASIVE AMBULATORY BLOOD-PRESSURE MEASURING DEVICES
    OBRIEN, E
    OMALLEY, K
    SHERIDAN, J
    [J]. JOURNAL OF HYPERTENSION, 1989, 7 : S19 - S20
  • [6] The 2020 "WHO Technical Specifications for Automated Non-Invasive Blood Pressure Measuring Devices With Cuff"
    John, Oommen
    Campbell, Norm R. C.
    Brady, Tammy M.
    Farrell, Margret
    Varghese, Cherian
    Berumen, Adriana Velazquez
    Gaitan, Laura A. Velez Ruiz
    Toffelmire, Nicola
    Ameel, Mohammad
    Mideksa, Mulugeta
    Jaffe, Marc G.
    Schutte, Aletta E.
    Khan, Taskeen
    Lopez Meneses, Laura Patricia
    [J]. HYPERTENSION, 2021, 77 (03) : 806 - 812
  • [7] Influence of arrhythmias on accuracy of non-invasive blood pressure monitors
    Cleland, MJ
    Miller, DR
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (07): : 699 - 705
  • [8] Influence of arrhythmias on accuracy of non-invasive blood pressure monitors
    Mark J. Cleland
    Ba Pham
    Donald R. Miller
    [J]. Canadian Journal of Anaesthesia, 1998, 45 : 699 - 705
  • [9] Automated non-invasive blood pressure devices: are they suitable for use?
    Sims, AJ
    Menes, JA
    Bousfield, DR
    Reay, CA
    Murray, A
    [J]. BLOOD PRESSURE MONITORING, 2005, 10 (05) : 275 - 281
  • [10] The influence of external factors on the accuracy of non-invasive measuring of oxygen in blood
    Snizhko, Y. M.
    Sarana, V. M.
    [J]. VISNYK OF DNIPROPETROVSK UNIVERSITY-BIOLOGY MEDICINE, 2016, 7 (02): : 78 - 82