A new non-invasive device for measuring instantaneous blood pressure in radial artery based on the volume-compensation method

被引:2
|
作者
Tanaka, S [1 ]
Gao, S [1 ]
Nogawa, M [1 ]
Yamakoshi, K [1 ]
机构
[1] Kanazawa Univ, Fac Engn, Kanazawa, Ishikawa 920, Japan
关键词
blood pressure; non-invasive measurement; radial artery; volume-compensation method;
D O I
10.1109/IEMBS.2003.1280810
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A prototype system for non-invasively measure instantaneous blood pressure (BP) in radial artery was newly devised. The system was based on the volume-compensation method, and several components were newly designed, i.e., a disk-type cuff for local pressurization and a nozzle-flapper type electro-pneumatic converter (EPC) for the cuff-pressure control. Results of experiments indicated that, using the disk-type cuff, the radial artery could be completely compressed, and newly devised EPC had sufficient frequency response for BP measurement in human. Also indicated was that the prototype system consisted with these component was capable of non-invasively measuring instantaneous blood pressure in radial artery, not only in rest condition, but also in a stressful condition such as cold pressor test.
引用
收藏
页码:3149 / 3152
页数:4
相关论文
共 50 条
  • [41] A new invasive validation method for non-invasive central blood pressure measurement using a suprasystolic sphygmomanometer
    Scalia, Alessandro
    Carlier, Stephane
    Thayse, Kathleen
    ACTA CARDIOLOGICA, 2019, 74 : 66 - 67
  • [42] A contribution from new technologies: towards a non-invasive method for measuring arterial pulse pressure?
    Gonzalez-Estevez, M.
    Robin, E.
    Vallet, B.
    REANIMATION, 2012, 21 (02): : 142 - 148
  • [43] Efficacy of a new blood pressure monitor (inflationary non-invasive blood pressure, iNIBP)
    Takahashi, Kei
    Asai, Takashi
    Okuda, Yasuhisa
    ANESTHESIA AND ANALGESIA, 2020, 130 : 970 - 970
  • [44] A new indicator for non-invasive arterial blood pressure measurement
    Regueiro-Gomez, A
    Pallas-Areny, R
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 117 - 118
  • [45] Non-invasive deformation measuring method based on image matching
    Han, F
    Bai, FZ
    Wang, J
    Tian, CP
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 2, 2004, : 254 - 258
  • [46] A non-invasive blood pressure prediction method based on pulse wave feature fusion
    Yan, Jianjun
    Cai, Xianglei
    Zhu, Guangyao
    Guo, Rui
    Yan, Haixia
    Wang, Yiqin
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 74
  • [47] A New Cuff Unit for Measuring Instantaneous Blood Pressure at the Finger Artery By local Pressurization
    Song, Yilin
    Gao, Shumei
    Ikarashi, Akira
    Yamakoshi, Ken-ichi
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1353 - +
  • [48] A New Method and a Non-Invasive Device to Estimate Anemia Based on Digital Images of the conjunctiva
    Dimauro, Giovanni
    Caivano, Danilo
    Girardi, Francesco
    IEEE ACCESS, 2018, 6 : 46968 - 46975
  • [49] New non-invasive sonographic modality for intracranial pressure/volume monitoring
    Fountas K.N.
    Sitkauskas A.
    Troup E.C.
    Feltes C.H.
    Dimopoulos V.
    Deltuva V.
    Daubaris G.
    Ragauskas A.
    Robinson Jr. J.S.
    Child’s Nervous System, 2002, 18 (5) : 211 - 214
  • [50] Research on a Non-Invasive Measuring Method of Blood Glucose Concentration Based on Electrical Impedance Spectrum
    Yin, Tong
    Chen, Xiaoyan
    Du, Meng
    Yin, Hongyi
    ICAROB 2019: PROCEEDINGS OF THE 2019 INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS, 2019, : 328 - 334