Biomechanical comparison between double-plate fixation and posterior plate fixation for comminuted olecranon fracture using two triceps screws in synthetic bone model

被引:1
|
作者
Lee, Yohan [1 ,2 ]
Cho, Bong Wan [3 ]
Kim, Min Bom [1 ,4 ]
Lee, Young Ho [1 ,4 ]
机构
[1] Seoul Natl Univ, Coll Med, Seoul, South Korea
[2] Seoul Natl Univ, Boramae Hosp, Dept Orthoped Surg, Seoul, South Korea
[3] Seoul Jaeil Hosp, Dept Orthoped Surg, Pyeongtaek, South Korea
[4] Seoul Natl Univ Hosp, Dept Orthoped Surg, 101 Daehak Ro, Seoul 03080, South Korea
关键词
biomechanical phenomena; bone plates; comminuted/surgery; fractures; olecranon process/surgery; COMPRESSION; SUTURE;
D O I
10.1097/MD.0000000000028313
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although preventing triceps fragment displacement is essential for treating an olecranon fracture, we frequently encounter situations in which only a few screws can be fixed to the triceps fragment. The aim of this study was to compare the stability of double-plate fixation and posterior plate fixation for olecranon fractures when the triceps fragment was small and only 2 screws could be inserted. Methods: A composite ulna model was used to simulate olecranon fracture. Four groups were formed consisting of double-plate and posterior plates with cortical and locking screws. The cyclic loading test was conducted for 500 cyclic loads of 5 to 50 N on a specimen to measure micromotion and displacement of the gap caused by light exercise. The load-to-failure test was performed by applying a load until fixation loss, defined as when the fracture gap increased by 2 mm or more or catastrophic failure occurred, to measure the maximum load. Results: Eight samples per group were tested through the pilot study. All groups were stable with a micromotion of <0.5 mm. However, the mean micromotion showed significant differences between the 4 groups (P< .001, Table 1). In the mean micromotion during exercise, posterior plating with cortical screws was the most stable (0.09 +/- 0.02 mm) while double-plating with cortical screws was the most unstable (0.42 +/- 0.11 mm). At the maximum load, posterior plating with locking screws was the strongest (205.3 +/- 2.8 N) while double-plating with cortical screws was the weakest (143.3 +/- 27.1 N). There was no significant difference in displacement after light exercise between the groups. Conclusions: This study showed that when 2 triceps screws were used, both groups were stable during light exercise, but posterior-plating was stronger than double-plating.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Biomechanical Comparison Between Posterior Long-Segment Fixation, Short-Segment Fixation, and Short-Segment Fixation With Intermediate Screws for the Treatment of Thoracolumbar Burst Fracture: A Finite Element Analysis
    Limthongkul, Worawat
    Wannaratsiri, Nutthee
    Sukjamsri, Chamaiporn
    Benyajati, Chi-Na
    Limthongkul, Pimpa
    Tanasansomboon, Teerachat
    Yingsakmongkol, Wicharn
    Singhatanadgige, Weerasak
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2023, 17 (03): : 442 - 448
  • [42] Coracoid bone graft osteolysis after Latarjet procedure: A comparison study between two screws standard technique vs mini-plate fixation
    Di Giacomo, Giovanni
    Costantini, Alberto
    de Gasperis, Nicola
    De Vita, Andrea
    Lin, Bernard K. H.
    Francone, Marco
    Beccaglia, Mario A. Rojas
    Mastantuono, Marco
    INTERNATIONAL JOURNAL OF SHOULDER SURGERY, 2013, 7 (01): : 1 - 6
  • [43] Palmar plate fixation of AO type C2 fracture of distal radius using a locking compression plate - A biomechanical study in a cadaveric model
    Leung, F
    Zhu, L
    Ho, H
    Lu, WW
    Chow, SP
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2003, 28B (03): : 263 - 266
  • [44] Biomechanical comparison of two locking plate constructs under cyclic torsional loading in a fracture gap model Two screws versus three screws per fragment
    Bilmont, A.
    Palierne, S.
    Verset, M.
    Swider, P.
    Autefage, A.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2015, 28 (05) : 323 - 330
  • [45] Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model
    Kousuke Iba
    Yasuhiro Ozasa
    Takuro Wada
    Tomoaki Kamiya
    Toshihiko Yamashita
    Mitsuhiro Aoki
    Journal of Orthopaedic Surgery and Research, 5
  • [46] Efficacy of radial styloid targeting screws in volar plate fixation of intra-articular distal radial fractures: a biomechanical study in a cadaver fracture model
    Iba, Kousuke
    Ozasa, Yasuhiro
    Wada, Takuro
    Kamiya, Tomoaki
    Yamashita, Toshihiko
    Aoki, Mitsuhiro
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2010, 5
  • [47] Comparison of Outcomes of Intertrochanteric Fracture Fixation Using Percutaneous Compression Plate Between Stable and Unstable Fractures in the Elderly
    Carvajal-Pedrosa, Cristina
    Gomez-Sanchez, Rafael C.
    Hernandez-Cortes, Pedro
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (06) : e201 - e206
  • [48] A Biomechanical Comparison of Short Segment Long Bone Fracture Fixation Techniques: Single Large Fragment Plate Versus 2 Small Fragment Plates
    Watts, Adriel
    Weinhold, Paul
    Kesler, William
    Dahners, Laurence
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (09) : 528 - 532
  • [49] Comparison of the Outcomes Between Headless Cannulated Screw Fixation and Fixation Using a Locking Compression Distal Ulna Hook Plate in Fracture of Fifth Metatarsal Base
    Kim, Jun-Beom
    Song, In-Soo
    Park, Byeong-Seop
    Ahn, Chi-Hoon
    Kim, Cheol-U
    JOURNAL OF FOOT & ANKLE SURGERY, 2017, 56 (04): : 713 - 717
  • [50] Biomechanical Comparison of Use of Two Screws versus Three Screws Per Fragment with Locking Plate Constructs under Cyclic Loading in Compression in a Fracture Gap Model
    Palierne, Sophie
    Blondel, Margaux
    Swider, Pascal
    Autefage, Andre
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2022, 35 (03) : 166 - 174