Biomechanical comparison between double-plate fixation and posterior plate fixation for comminuted olecranon fracture using two triceps screws in synthetic bone model

被引:1
|
作者
Lee, Yohan [1 ,2 ]
Cho, Bong Wan [3 ]
Kim, Min Bom [1 ,4 ]
Lee, Young Ho [1 ,4 ]
机构
[1] Seoul Natl Univ, Coll Med, Seoul, South Korea
[2] Seoul Natl Univ, Boramae Hosp, Dept Orthoped Surg, Seoul, South Korea
[3] Seoul Jaeil Hosp, Dept Orthoped Surg, Pyeongtaek, South Korea
[4] Seoul Natl Univ Hosp, Dept Orthoped Surg, 101 Daehak Ro, Seoul 03080, South Korea
关键词
biomechanical phenomena; bone plates; comminuted/surgery; fractures; olecranon process/surgery; COMPRESSION; SUTURE;
D O I
10.1097/MD.0000000000028313
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although preventing triceps fragment displacement is essential for treating an olecranon fracture, we frequently encounter situations in which only a few screws can be fixed to the triceps fragment. The aim of this study was to compare the stability of double-plate fixation and posterior plate fixation for olecranon fractures when the triceps fragment was small and only 2 screws could be inserted. Methods: A composite ulna model was used to simulate olecranon fracture. Four groups were formed consisting of double-plate and posterior plates with cortical and locking screws. The cyclic loading test was conducted for 500 cyclic loads of 5 to 50 N on a specimen to measure micromotion and displacement of the gap caused by light exercise. The load-to-failure test was performed by applying a load until fixation loss, defined as when the fracture gap increased by 2 mm or more or catastrophic failure occurred, to measure the maximum load. Results: Eight samples per group were tested through the pilot study. All groups were stable with a micromotion of <0.5 mm. However, the mean micromotion showed significant differences between the 4 groups (P< .001, Table 1). In the mean micromotion during exercise, posterior plating with cortical screws was the most stable (0.09 +/- 0.02 mm) while double-plating with cortical screws was the most unstable (0.42 +/- 0.11 mm). At the maximum load, posterior plating with locking screws was the strongest (205.3 +/- 2.8 N) while double-plating with cortical screws was the weakest (143.3 +/- 27.1 N). There was no significant difference in displacement after light exercise between the groups. Conclusions: This study showed that when 2 triceps screws were used, both groups were stable during light exercise, but posterior-plating was stronger than double-plating.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Comparison of the fixation ability between lag screw and bone plate for oblique metacarpal shaft fracture
    Yung-Cheng Chiu
    Tsung-Yu Ho
    Cheng-En Hsu
    Yen-Nien Ting
    Ming-Tzu Tsai
    Jui-Ting Hsu
    Journal of Orthopaedic Surgery and Research, 17
  • [32] A biomechanical comparison of posterior malleolar fracture fixation using screws and locking plates in Trimalleolar fractures: a finite element study
    Chang, Chih-Wei
    Chen, Yen-Nien
    Jhong, Guan-Heng
    Su, Kuo-Chih
    Li, Chun-Ting
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [33] BIOMECHANICAL COMPARISON OF ANTERIOR CASPAR PLATE AND 3-LEVEL POSTERIOR FIXATION TECHNIQUES IN A HUMAN CADAVERIC MODEL
    TRAYNELIS, VC
    DONAHER, PA
    ROACH, RM
    KOJIMOTO, H
    GOEL, VK
    JOURNAL OF NEUROSURGERY, 1993, 79 (01) : 96 - 103
  • [34] A biomechanical study comparing plate fixation using unicortical and bicortical screws in transverse metacarpal fracture models subjected to cyclic loading
    Afshar, R.
    Fong, T. S.
    Latifi, M. Hadi
    Kanthan, S. R.
    Kamarul, T.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2012, 37E (05) : 396 - 401
  • [35] Distal radius fracture fixation using volar plate: A comparative study evaluating the biomechanical behavior of uni and bicortical distal screws
    Neder Filho, Antonio Tufi
    Mazzer, Nilton
    Bataglion, Leonardo Rigobello
    Pires, Robinson Esteves
    Macedo, Ana Paula
    Shimano, Antonio Carlos
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 : S38 - S43
  • [36] Comparison of 2 different fixation techniques of comminuted acetabular quadrilateral surface fractures using square bracket-shaped tubular plate or interfragmentary screws in addition to supra/infrapectineal plate fixation: An observational study
    Kilinc, Cem Yalin
    Gultac, Emre
    Can, Fatih Ilker
    Kilinc, Rabia Mihriban
    Sener, Burak
    Acan, Ahmet Emrah
    MEDICINE, 2024, 103 (20) : E38252
  • [37] Comparison between anterior-to-posterior screw fixation versus posterolateral approach plate fixation for posterior malleous fracture: A systematic review and meta-analysis
    Gao, Yuling
    Liu, Yang
    Zhao, Yanrui
    Shan, Lei
    Wang, Hanzhou
    Xu, Xiaopei
    Zhao, Binzhi
    Zhou, Junlin
    FOOT AND ANKLE SURGERY, 2024, 30 (07) : 594 - 602
  • [38] Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate
    Krischak, G. D.
    Augat, P.
    Beck, A.
    Arand, M.
    Baler, B.
    Blakytny, R.
    Gebhard, F.
    Claes, L.
    CLINICAL BIOMECHANICS, 2007, 22 (10) : 1112 - 1118
  • [39] FIXATION OF DISPLACED FEMORAL-NECK FRACTURES - A COMPARISON BETWEEN SLIDING SCREW PLATE AND 4 CANCELLOUS BONE SCREWS
    MADSEN, F
    LINDE, F
    ANDERSEN, E
    BIRKE, H
    HVASS, I
    POULSEN, TD
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03): : 212 - 216
  • [40] An in vitro biomechanical comparison between prototype tapered shaft cortical bone screws and AO cortical bone screws for an equine metacarpal dynamic compression plate fixation of osteotomized equine third metacarpal bones
    Sod, Gary A.
    Hubert, Jeremy D.
    Martin, George S.
    Gill, Marjorie S.
    VETERINARY SURGERY, 2006, 35 (07) : 634 - 642