Biomechanical comparison between double-plate fixation and posterior plate fixation for comminuted olecranon fracture using two triceps screws in synthetic bone model

被引:1
|
作者
Lee, Yohan [1 ,2 ]
Cho, Bong Wan [3 ]
Kim, Min Bom [1 ,4 ]
Lee, Young Ho [1 ,4 ]
机构
[1] Seoul Natl Univ, Coll Med, Seoul, South Korea
[2] Seoul Natl Univ, Boramae Hosp, Dept Orthoped Surg, Seoul, South Korea
[3] Seoul Jaeil Hosp, Dept Orthoped Surg, Pyeongtaek, South Korea
[4] Seoul Natl Univ Hosp, Dept Orthoped Surg, 101 Daehak Ro, Seoul 03080, South Korea
关键词
biomechanical phenomena; bone plates; comminuted/surgery; fractures; olecranon process/surgery; COMPRESSION; SUTURE;
D O I
10.1097/MD.0000000000028313
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although preventing triceps fragment displacement is essential for treating an olecranon fracture, we frequently encounter situations in which only a few screws can be fixed to the triceps fragment. The aim of this study was to compare the stability of double-plate fixation and posterior plate fixation for olecranon fractures when the triceps fragment was small and only 2 screws could be inserted. Methods: A composite ulna model was used to simulate olecranon fracture. Four groups were formed consisting of double-plate and posterior plates with cortical and locking screws. The cyclic loading test was conducted for 500 cyclic loads of 5 to 50 N on a specimen to measure micromotion and displacement of the gap caused by light exercise. The load-to-failure test was performed by applying a load until fixation loss, defined as when the fracture gap increased by 2 mm or more or catastrophic failure occurred, to measure the maximum load. Results: Eight samples per group were tested through the pilot study. All groups were stable with a micromotion of <0.5 mm. However, the mean micromotion showed significant differences between the 4 groups (P< .001, Table 1). In the mean micromotion during exercise, posterior plating with cortical screws was the most stable (0.09 +/- 0.02 mm) while double-plating with cortical screws was the most unstable (0.42 +/- 0.11 mm). At the maximum load, posterior plating with locking screws was the strongest (205.3 +/- 2.8 N) while double-plating with cortical screws was the weakest (143.3 +/- 27.1 N). There was no significant difference in displacement after light exercise between the groups. Conclusions: This study showed that when 2 triceps screws were used, both groups were stable during light exercise, but posterior-plating was stronger than double-plating.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] A Biomechanical and Clinical Comparison of Midshaft Clavicle Plate Fixation: Are 2 Screws as Good as 3 on Each Side of the Fracture?
    Larsen, Christopher G.
    Sleasman, Brian
    Chudik, Steven C.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2017, 5 (09):
  • [22] Skeletal stability after mandibular setback surgery: Comparison between the hybrid technique for fixation and the conventional plate fixation using an absorbable plate and screws
    Ueki, Koichiro
    Okabe, Katsuhiko
    Marukawa, Kohei
    Mukozawa, Aya
    Moroi, Akinori
    Miyazaki, Mao
    Sotobori, Megumi
    Ishihara, Yuri
    Yoshizawa, Kunio
    Ooi, Kazuhiro
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (04) : 351 - 355
  • [23] Triceps Tendon Reattachment Using Mini Plates and Screws After Failure of Olecranon Avulsion Fracture Fixation in Osteoporotic Bone: A Case Report
    Pohl, Nicholas B.
    Brush, Parker L.
    Russo, James
    Fras, Sebastian I.
    Beredjiklian, Pedro K.
    Fletcher, Daniel J.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2025, 20 (02): : NP1 - NP5
  • [24] Posterior column acetabular fracture fixation using a W-shaped angular plate: A biomechanical analysis
    Su, Ke
    Liu, Song
    Wu, Tao
    Yin, Yingchao
    Zhang, Ruipeng
    Li, Shilun
    Zhang, Yingze
    PLOS ONE, 2017, 12 (11):
  • [25] Biomechanical comparison of a proximal humeral locking plate using two methods of head fixation
    Schumer, Ross A.
    Muckley, Kara L.
    Markert, Ronald J.
    Prayson, Michael J.
    Heflin, Jonathan
    Konstantakos, Emmanuel K.
    Goswami, Tarun
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2010, 19 (04) : 495 - 501
  • [26] A Biomechanical Comparison of Two Triple-Screw Methods for Femoral Neck Fracture Fixation in a Synthetic Bone Model
    Zdero, Rad
    Keast-Butler, Oliver
    Schemitsch, Emil H.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 69 (06): : 1537 - 1544
  • [27] Biomechanical comparison of monocortical and bicortical plate fixation for rib fractures in a cadaveric model using a locking plate system
    Choke, Abby
    Wong, Yoke Rung
    Joethy, Janna-Vale
    JOURNAL OF THORACIC DISEASE, 2019, 11 (12) : 4966 - 4971
  • [28] A Biomechanical Comparison of Locked Plate Fixation With Percutaneous Insertion Capability Versus the Angled Blade Plate in a Subtrochanteric Fracture Gap Model
    Crist, Brett D.
    Khalafi, Afshin
    Hazelwood, Scott J.
    Lee, Mark A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (09) : 622 - 627
  • [29] Biomechanical comparison of pin and tension-band wire fixation with a prototype locking plate fixation in a transverse canine patellar fracture model
    Gibert, Sophie
    Kowaleski, Michael P.
    Matthys, Romano
    Nuetzi, Reto
    Serck, Boris
    Boudrieau, Randy J.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2016, 29 (01) : 20 - 28
  • [30] Comparison of the fixation ability between lag screw and bone plate for oblique metacarpal shaft fracture
    Chiu, Yung-Cheng
    Ho, Tsung-Yu
    Hsu, Cheng-En
    Ting, Yen-Nien
    Tsai, Ming-Tzu
    Hsu, Jui-Ting
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)