Validation of the A&D UM-211 device for office blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010

被引:4
|
作者
Fania, Claudio [1 ]
Albertini, Federica [1 ]
Palatini, Paolo [1 ]
机构
[1] Univ Padua, Dept Med, Via Giustiniani 2, I-35128 Padua, Italy
关键词
cuff; device; office blood pressure; self-measurement; validation;
D O I
10.1097/MBP.0000000000000266
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The aim of this study was to define the accuracy of UM-211, an automated oscillometric device for office use coupled to several cuffs for different arm sizes, according to the International Protocol of the European Society of Hypertension. The validation was performed in 33 individuals. Their mean age was 59.6 +/- 12.9 years, systolic blood pressure (BP) was 144.3 +/- 21.5mmHg (range: 96-184mmHg), diastolic BP was 86.8 +/- 18.5mmHg (range: 48-124 mmHg), and arm circumference was 30.2 +/- 4.3 cm (range: 23-39 cm). Four sequential readings were taken by observers 1 and 2 using a double-headed stethoscope and a mercury sphygmomanometer, whereas three BP readings were taken by the supervisor using the test instrument. The differences between the readings provided by the device and the mean observer measurements were calculated. Therefore, each device measurement was compared with the previous and the next mean observer measurement. The validation results fulfilled all the 2010 European Society of Hypertension revision Protocol criteria for the general population and passed all validation grades. On average, the device overestimated systolic BP by 1.7 +/- 2.4mmHg and diastolic BP by 1.7 +/- 2.5mmHg. These data show that the UM-211 device coupled to several cuffs for different ranges of arm circumference met the requirements for validation according to the International Protocol and can be recommended for clinical use in the adult population. However, these results mainly apply to the use of the 22-32 and the 31-45 cm cuffs. Copyright (C) 2017 Wolters Kluwer Health, Inc. All rights reserved.
引用
收藏
页码:302 / 305
页数:4
相关论文
共 50 条
  • [21] Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
    Bilo, Grzegorz
    Zorzi, Cristina
    Munera, Juan E. Ochoa
    Torlasco, Camilla
    Giuli, Valentina
    Parati, Gianfranco
    BLOOD PRESSURE MONITORING, 2015, 20 (05) : 291 - 294
  • [22] Validation of the iHealth BP7 wrist blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010
    Wang, Qing
    Zhao, Huadong
    Chen, Wan
    Li, Ni
    Wan, Yi
    BLOOD PRESSURE MONITORING, 2014, 19 (01) : 54 - 57
  • [23] Validation of the Medisana MTP Plus upper arm blood pressure monitor, for self-measurement, according to the European Society of Hypertension International Protocol revision 2010
    Erdem, Emre
    Aydogdu, Turkan
    Akpolat, Tekin
    BLOOD PRESSURE MONITORING, 2011, 16 (01) : 43 - 46
  • [24] Validation of the Globalcare GCE603 automated blood pressure monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010
    Song, Cheng
    Yu, Yang
    Lu, Bao-Chuan
    Yan, Xi-Ling
    BLOOD PRESSURE MONITORING, 2020, 25 (05) : 291 - 294
  • [25] Validation of the Tensoval Duo Control II blood pressure monitor for clinic use and self-measurement according to the British Hypertension Society protocol and the European Society of Hypertension International Protocol revision 2010
    de Greeff, Annemarie
    Shennan, Andrew H.
    BLOOD PRESSURE MONITORING, 2013, 18 (03) : 161 - 166
  • [26] Validation of the Microlife WatchBP Office professional device for office blood pressure measurement according to the International Protocol
    Stergiou, G.
    Tzamouranis, D.
    Protogerou, A.
    Nasothimiou, E.
    Kapralos, C.
    JOURNAL OF HYPERTENSION, 2008, 26 : S481 - S481
  • [27] VALIDATION OF THREE AUTOMATIC BLOOD PRESSURE MONITORS FOR SELF-MEASUREMENT ACCORDING TO EUROPEAN SOCIETY OF HYPERTENSION INTERNATIONAL PROTOCOL REVERSION 2010
    Tian, H.
    Zeng, S. Y.
    Zhong, Z. Y.
    Gong, W.
    Liu, W. J.
    JOURNAL OF HYPERTENSION, 2015, 33 : E155 - E155
  • [28] Validation of the Andon KD-5851 upper arm blood pressure monitor, for self-measurement according to the European Society of Hypertension International Protocol revision 2010
    Wu, Lili
    Jiao, Yinghui
    Wang, Chengdong
    Chen, Lei
    Di, Dalin
    Zhang, Haiyan
    BLOOD PRESSURE MONITORING, 2015, 20 (04) : 228 - 231
  • [29] Validation in the General Population of the iHealth Track Blood Pressure Monitor for Self-Measurement According to the European Society of Hypertension International Protocol Revision 2010: Descriptive Investigation
    Mazoteras-Pardo, Victoria
    Becerro-De-Bengoa-Vallejo, Ricardo
    Elena Losa-Iglesias, Marta
    Lopez-Lopez, Daniel
    Palomo-Lopez, Patricia
    Rodriguez-Sanzl, David
    Calvo-Lobo, Cesar
    JMIR MHEALTH AND UHEALTH, 2019, 7 (03):
  • [30] Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010
    Kang, Yuan-Yuan
    Chen, Qi
    Li, Yan
    Wang, Ji-Guang
    BLOOD PRESSURE MONITORING, 2016, 21 (04) : 255 - 258