Quantification of Cold Spots Caused by Geometrical Uncertainty in Field-in-field Techniques for Whole Breast Radiotherapy

被引:8
|
作者
Nakamura, Naoki [1 ]
Hatanaka, Shogo
Shikama, Naoto [2 ]
Akahane, Keiko
Sekiguchi, Kenji
机构
[1] St Lukes Int Hosp, Dept Radiat Oncol, Chuoh Ku, Tokyo 1048560, Japan
[2] Saitama Med Univ Hosp, Dept Radiat Oncol, Hidaka, Japan
关键词
breast cancer; radiotherapy; whole breast radiotherapy; field-in-field technique; geometrical uncertainty; INTENSITY MODULATION; DOSE DISTRIBUTIONS; IRRADIATION; IMRT; MOTION;
D O I
10.1093/jjco/hyr112
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: To quantify the cold spot under geometrical uncertainties in field-in-field techniques for whole breast radiotherapy. Methods: Ten consecutive patients from both the left-and right-sided treatment site groups who received whole breast radiotherapy with the field-in-field technique were included. Virtual plans were made with moving isocenters to the posterior direction having two amplitudes (5 and 10 mm) and prescribing the same monitor unit as the original plan (FIF_5 and FIF_10). The planning target volume for evaluation was defined by subtracting the areas within 5 mm from the skin and within 5 mm from the lung from the whole breast. The differences in V90, V95 and D98 of planning target volume for evaluation were measured between the original and virtual plans. As a reference, the same measurements were taken for the wedge techniques (Wedge_5 and Wedge_10). Results: The differences in V95 were -0.2% on FIF_5, -1.7% on FIF_10, -0.5% on Wedge_5 and -1.5% on Wedge_10. The differences in V90 were -0.02% on FIF_5, -0.3% on FIF_10, 0.05% on Wedge_5 and 0.1% on Wedge_10. The differences in D98 were 0 Gy on FIF_5, -0.1 Gy on FIF_10, -0.2 Gy on Wedge_5 and -0.4 Gy on Wedge_10. The differences in D98 between the original plans and virtual scenarios for field-in-field techniques were significantly smaller than those for wedge techniques, but there were no statically significant differences in V90 and V95. Conclusions: The quantity of the cold spots caused by the geometrical uncertainties in field-in-field techniques was similar to that for the wedge techniques and was acceptable.
引用
收藏
页码:1127 / 1131
页数:5
相关论文
共 50 条
  • [31] Whole breast irradiation for small-sized breasts after conserving surgery: is the field-in-field technique optimal?
    Yang, Dae Sik
    Lee, Jung Ae
    Yoon, Won Sup
    Chung, Se Young
    Lee, Suk
    Kim, Chul Yong
    Park, Young Je
    Son, Gil Soo
    BREAST CANCER, 2014, 21 (02) : 162 - 169
  • [32] Effects of Geometrical Uncertainties on Whole Breast Radiotherapy: A Comparison of Four Different Techniques
    Nakamura, Naoki
    Takahashi, Osamu
    Karno, Minobu
    Hatanaka, Shogo
    Endo, Hartma
    Mizuno, Norifumi
    Shikama, Naoto
    Ogita, Many
    Sekiguchi, Kenji
    JOURNAL OF BREAST CANCER, 2014, 17 (02) : 157 - 160
  • [33] Whole breast irradiation for small-sized breasts after conserving surgery: is the field-in-field technique optimal?
    Dae Sik Yang
    Jung Ae Lee
    Won Sup Yoon
    Se Young Chung
    Suk Lee
    Chul Yong Kim
    Young Je Park
    Gil Soo Son
    Breast Cancer, 2014, 21 : 162 - 169
  • [34] COMPARISION OF ANTEROPOSTERIOR-POSTEROANTERIOR (AP-PA), TWO LATERAL AND FIELD-IN-FIELD TECHNIQUES IN WHOLE BODY IRRADIATION
    Sonmez, A.
    Oymak, E.
    Efe, E.
    Sonmez, S.
    Arslan, G.
    Onal, H. C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S496 - S497
  • [35] Dosimetry Parameter Comparison Between Field-In-Field Technique and Conventional Physical Wedge Technique for Whole Breast Radiation Treatment
    Su, M.
    Ayzenberg, V.
    Li, W.
    MEDICAL PHYSICS, 2012, 39 (06) : 3806 - 3806
  • [36] Experimental determination of breast skin dose using volumetric modulated arc therapy and field-in-field treatment techniques
    Maria Cardona-Maya, Ana
    Alejandro Rojas-Lopez, Jose
    Germanier, Alejandro
    Murina, Patricia
    Venencia, Daniel
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 22
  • [37] PLANNING COMPARISON OF FIELD-IN-FIELD TECHNIQUE (FIF) WITH ECLIPSE'S IRREGULAR SURFACE COMPENSATOR MODULE (SCP) IN BREAST RADIOTHERAPY
    Vinh-Hung, V.
    Nouet, P.
    Lee, Y. E.
    Fargier-Bochaton, O.
    Rouzaud, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2011, 187 (08) : 539 - 539
  • [38] Impact of respiratory motion on breast tangential radiotherapy using the field-in-field technique compared to irradiation using physical wedges
    Tanaka, Hidekazu
    Hayashi, Shinya
    Ohtakara, Kazuhiro
    Hoshi, Hiroaki
    RADIOLOGY AND ONCOLOGY, 2014, 48 (01) : 94 - 98
  • [39] Dosimetric Comparison of Whole Breast Irradiation Using Helical Tomographic Technique and Static Multileaf Collimated Field-In-Field Technique
    Hsieh, H.
    Chang, S.
    Yuan, J.
    Pino-y-Torres, J.
    Chen, W.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [40] Variation of V105% between pre- and postmerged subfields in field-in-field hypofractionated breast radiotherapy plans
    Dwivedi, Abhishek
    McGarry, Therese
    Bond, Laura
    Braver, Joel K.
    Biswal, Nrusingh C.
    MEDICAL DOSIMETRY, 2020, 45 (01) : 19 - 20