Quantification of Cold Spots Caused by Geometrical Uncertainty in Field-in-field Techniques for Whole Breast Radiotherapy

被引:8
|
作者
Nakamura, Naoki [1 ]
Hatanaka, Shogo
Shikama, Naoto [2 ]
Akahane, Keiko
Sekiguchi, Kenji
机构
[1] St Lukes Int Hosp, Dept Radiat Oncol, Chuoh Ku, Tokyo 1048560, Japan
[2] Saitama Med Univ Hosp, Dept Radiat Oncol, Hidaka, Japan
关键词
breast cancer; radiotherapy; whole breast radiotherapy; field-in-field technique; geometrical uncertainty; INTENSITY MODULATION; DOSE DISTRIBUTIONS; IRRADIATION; IMRT; MOTION;
D O I
10.1093/jjco/hyr112
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: To quantify the cold spot under geometrical uncertainties in field-in-field techniques for whole breast radiotherapy. Methods: Ten consecutive patients from both the left-and right-sided treatment site groups who received whole breast radiotherapy with the field-in-field technique were included. Virtual plans were made with moving isocenters to the posterior direction having two amplitudes (5 and 10 mm) and prescribing the same monitor unit as the original plan (FIF_5 and FIF_10). The planning target volume for evaluation was defined by subtracting the areas within 5 mm from the skin and within 5 mm from the lung from the whole breast. The differences in V90, V95 and D98 of planning target volume for evaluation were measured between the original and virtual plans. As a reference, the same measurements were taken for the wedge techniques (Wedge_5 and Wedge_10). Results: The differences in V95 were -0.2% on FIF_5, -1.7% on FIF_10, -0.5% on Wedge_5 and -1.5% on Wedge_10. The differences in V90 were -0.02% on FIF_5, -0.3% on FIF_10, 0.05% on Wedge_5 and 0.1% on Wedge_10. The differences in D98 were 0 Gy on FIF_5, -0.1 Gy on FIF_10, -0.2 Gy on Wedge_5 and -0.4 Gy on Wedge_10. The differences in D98 between the original plans and virtual scenarios for field-in-field techniques were significantly smaller than those for wedge techniques, but there were no statically significant differences in V90 and V95. Conclusions: The quantity of the cold spots caused by the geometrical uncertainties in field-in-field techniques was similar to that for the wedge techniques and was acceptable.
引用
收藏
页码:1127 / 1131
页数:5
相关论文
共 50 条
  • [21] IMPLEMENTATION OF MLC "FIELD-IN-FIELD" TANGENTIAL TECHNIQUE FOR WHOLE BREAST IRRADIATION OF LARGE BREASTED WOMEN
    Melidis, C.
    Mponiou, K.
    Kotzassarlidou, M.
    Charalampidou, M.
    Makridou, A.
    Destouni, E.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S502 - S502
  • [22] Effects of Setup Errors on Dose Distribution for Tangential Wedge Field and Field-in-Field Techniques During Breast Irradiation
    Sonmez, Aydan
    Onal, Cem
    Sonmez, Serhat
    Arslan, Gungor
    Parlak, Cem
    Topkan, Erkan
    Yavuz, Melek
    UHOD-ULUSLARARASI HEMATOLOJI-ONKOLOJI DERGISI, 2014, 24 (02): : 130 - 138
  • [23] New field-in-field with two reference points method for whole breast radiotherapy: Dosimetric analysis and radiation-induced skin toxicities assessment
    Tekiki, Nouha
    Kuroda, Masahiro
    Ishizaka, Hinata
    Khasawneh, Abdullah
    Barham, Majd
    Hamada, Kentaro
    Konishi, Kohei
    Sugimoto, Kohei
    Katsui, Kuniaki
    Sugiyama, Soichi
    Watanabe, Kenta
    Yoshio, Kotaro
    Katayama, Norihisa
    Ogata, Takeshi
    Ihara, Hiroki
    Kanazawa, Susumu
    Asaumi, Junichi
    MOLECULAR AND CLINICAL ONCOLOGY, 2021, 15 (03)
  • [24] Radiation Damage Comparison Between Intensity Modulated Radiotherapy and Field-In-Field Technique in Breast Cancer Treatments
    Ai, H.
    Zhang, H.
    MEDICAL PHYSICS, 2014, 41 (06) : 286 - 286
  • [25] Intensity modulation in breast radiotherapy: Development of an innovative field-in-field technique at Institut Gustave-Roussy
    Heymann, S.
    Verstraet, R.
    Pichenot, C.
    Vergne, E.
    Lefkopoulos, D.
    Husson, F.
    Kafrouni, H.
    Mahe, J.
    Kandalaft, B.
    Bourhis, J.
    Marsiglia, H.
    Bourgier, C.
    CANCER RADIOTHERAPIE, 2011, 15 (08): : 663 - 669
  • [26] Verification of Monitor Unit Calculations for Breast Field-In-Field Three-Dimensional Conformal Radiotherapy Plans
    Kosztyla, Robert
    Pierce, Greg
    Ploquin, Nicolas
    Roumeliotis, Michael
    Schinkel, Colleen
    MEDICAL PHYSICS, 2016, 43 (08) : 4940 - 4941
  • [27] Low-Dose-Area-Constrained Helical Tomo Therapy-Based Whole Breast Radiotherapy and Dosimetric Comparison with Tangential Field-in-Field IMRT
    Qiu, Jie
    Liu, Zhikai
    Yang, Bo
    Hou, Xiaorong
    Zhang, Fuquan
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [28] The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques
    Furuya, Tomohisa
    Sugimoto, Satoru
    Kurokawa, Chie
    Ozawa, Shuichi
    Karasawa, Kumiko
    Sasai, Keisuke
    JOURNAL OF RADIATION RESEARCH, 2013, 54 (01) : 157 - 165
  • [29] Experimental Determination of Breast Skin Dose On Anthropomorphic Phantom Using VMAT and Field-In-Field Treatment Techniques
    Cardona, A.
    Rojas-Lopez, J.
    Murina, P.
    Germanier, A.
    Venencia, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E921 - E921
  • [30] Field-in-field plan does not improve the dosimetric outcome compared with the wedged beams plan for breast cancer radiotherapy
    Sun, Li-Min
    Meng, Fan-Yun
    Yang, Tsung-Han
    Tsao, Min-Jen
    MEDICAL DOSIMETRY, 2014, 39 (01) : 79 - 82