摘要
Objective: To quantify the cold spot under geometrical uncertainties in field-in-field techniques for whole breast radiotherapy. Methods: Ten consecutive patients from both the left-and right-sided treatment site groups who received whole breast radiotherapy with the field-in-field technique were included. Virtual plans were made with moving isocenters to the posterior direction having two amplitudes (5 and 10 mm) and prescribing the same monitor unit as the original plan (FIF_5 and FIF_10). The planning target volume for evaluation was defined by subtracting the areas within 5 mm from the skin and within 5 mm from the lung from the whole breast. The differences in V90, V95 and D98 of planning target volume for evaluation were measured between the original and virtual plans. As a reference, the same measurements were taken for the wedge techniques (Wedge_5 and Wedge_10). Results: The differences in V95 were -0.2% on FIF_5, -1.7% on FIF_10, -0.5% on Wedge_5 and -1.5% on Wedge_10. The differences in V90 were -0.02% on FIF_5, -0.3% on FIF_10, 0.05% on Wedge_5 and 0.1% on Wedge_10. The differences in D98 were 0 Gy on FIF_5, -0.1 Gy on FIF_10, -0.2 Gy on Wedge_5 and -0.4 Gy on Wedge_10. The differences in D98 between the original plans and virtual scenarios for field-in-field techniques were significantly smaller than those for wedge techniques, but there were no statically significant differences in V90 and V95. Conclusions: The quantity of the cold spots caused by the geometrical uncertainties in field-in-field techniques was similar to that for the wedge techniques and was acceptable.
引用
收藏
页码:1127 / 1131
页数:5
相关论文
共 50 条
  • [1] Dosimetric Comparison of Irregular Surface Compensator and Field-in-Field for Whole Breast Radiotherapy
    Kuwahata, Nao
    Fujita, Hideki
    Yamanishi, Hideaki
    Okazaki, Eiichiro
    Fukuda, Haruyuki
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (02) : 79 - 84
  • [2] Automated field-in-field whole brain radiotherapy planning
    Huang, Kai
    Hernandez, Soleil
    Wang, Chenyang
    Nguyen, Callistus
    Briere, Tina Marie
    Cardenas, Carlos
    Court, Laurence
    Xiao, Yao
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (02):
  • [3] Dosimetric evaluation of whole breast radiotherapy using field-in-field technique in early-stage breast cancer
    Masahiro Sasaoka
    Tomoyuki Futami
    International Journal of Clinical Oncology, 2011, 16 : 250 - 256
  • [4] Dosimetric evaluation of whole breast radiotherapy using field-in-field technique in early-stage breast cancer
    Sasaoka, Masahiro
    Futami, Tomoyuki
    INTERNATIONAL JOURNAL OF CLINICAL ONCOLOGY, 2011, 16 (03) : 250 - 256
  • [5] Automated Field-In-Field Integrated with Aperture Prediction for Whole Brain Radiotherapy
    Huang, K.
    Xiao, Y.
    Hernandez, S.
    Nguyen, C.
    Wang, C.
    Briere, T.
    Cardenas, C.
    Court, L.
    MEDICAL PHYSICS, 2022, 49 (06) : E669 - E669
  • [6] Dosimetric Comparison of Whole Breast Radiotherapy Using Field-in-Field and Volumetric Modulated Arc Therapy Techniques in Left-Sided Breast Cancer Patients
    Waheed, Asmara
    Butt, Sumera
    Ishtiaq, Ali
    Mansha, Muhammad Atif
    Mehreen, Sana
    Raza, Mohsin
    Yousaf, Muhammad
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (06)
  • [7] Usefulness of the dual energy field-in-field technique in breast tangential radiotherapy
    Tanaka, Hidekazu
    Kajiura, Yuichi
    Kitahara, Masashi
    Matsuyama, Katsuya
    Kawaguchi, Masaya
    Yamaguchi, Takahiro
    Okada, Sunaho
    Kanematsu, Masayuki
    RADIOLOGIA MEDICA, 2016, 121 (04): : 323 - 326
  • [8] Usefulness of the dual energy field-in-field technique in breast tangential radiotherapy
    Hidekazu Tanaka
    Yuichi Kajiura
    Masashi Kitahara
    Katsuya Matsuyama
    Masaya Kawaguchi
    Takahiro Yamaguchi
    Sunaho Okada
    Masayuki Kanematsu
    La radiologia medica, 2016, 121 : 323 - 326
  • [9] Evaluation of the field-in-field technique with lung blocks for breast tangential radiotherapy
    Tanaka, Hidekazu
    Hayashi, Shinya
    Kajiura, Yuichi
    Kitahara, Masashi
    Matsuyama, Katsuya
    Kanematsu, Masayuki
    Hoshi, Hiroaki
    NAGOYA JOURNAL OF MEDICAL SCIENCE, 2015, 77 (03): : 339 - 345
  • [10] Determination of the optimal method for the field-in-field technique in breast tangential radiotherapy
    Tanaka, Hidekazu
    Hayashi, Shinya
    Hoshi, Hiroaki
    JOURNAL OF RADIATION RESEARCH, 2014, 55 (04) : 769 - 773