Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection

被引:57
|
作者
Kim, Ki-Seong [1 ,2 ]
Lim, Young-Jun [1 ,2 ]
Kim, Myung-Joo [1 ,2 ]
Kwon, Ho-Beom [1 ,2 ]
Yang, Jae-Ho [1 ,2 ]
Lee, Jai-Bong [1 ,2 ]
Yim, Soon-Ho [3 ]
机构
[1] Seoul Natl Univ, Dept Prosthodont, Sch Dent, Seoul 110749, South Korea
[2] Seoul Natl Univ, Dent Res Inst, Sch Dent, Seoul 110749, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Prosthodont,Inst Oral Hlth Sci, Seoul, South Korea
关键词
dental implants; implant-abutment interface; repeated tightening; settling effect; tightening torque; SCREW JOINT STABILITY; OSSEOINTEGRATED IMPLANTS; COMPLICATIONS; MISFIT;
D O I
10.1111/j.1600-0501.2010.02063.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Settling (embedment relaxation), which is the main cause for screw loosening, is developed by microroughness between implant and abutment metal surface. The objective of this study was to evaluate and compare the relationship between the level of applied torque and the settling of abutments into implants in external and internal implant-abutment connection. Material and methods: Five different implant-abutment connections were used (Ext, External butt joint + two-piece abutment; Int-H2, Internal hexagon + two-piece abutment; Int-H1, Internal hexagon + one-piece abutment; Int-O2, Internal octagon + two-piece abutment; Int-O1, Internal octagon + one-piece abutment). All abutments of each group were assembled and tightened with corresponding implants by a digital torque gauge. The total lengths of implant-abutment samples were measured at each torque (5, 10, 30 N cm and repeated 30 N cm with 10-min interval) by an electronic digital micrometer. The settling values were calculated by changes between the total lengths of implant-abutment samples. Results: All groups developed settling with repeated tightening. The Int-H2 group showed markedly higher settling for all instances of tightening torque and the Ext group was the lowest. Statistically significant differences were found in settling values between the groups and statistically significant increases were observed within each group at different tightening torques (P<0.05). After the second tightening of 30 N cm, repeated tightening showed almost constant settling values. Conclusions: Results from the present study suggested that to minimize the settling effect, abutment screws should be retightened at least twice at 30 N cm torque at a 10-min interval in all laboratory and clinical procedures.
引用
收藏
页码:834 / 839
页数:6
相关论文
共 50 条
  • [1] Axial displacements in external and internal implant-abutment connection
    Lee, Ji-Hye
    Kim, Dae-Gon
    Park, Chan-Jin
    Cho, Lee-Ra
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) : E83 - E89
  • [2] The implant-abutment connection
    Nelson, Katja
    Zabler, Simon
    Wiest, Wolfram
    Schmelzeisen, Rainer
    Semper-Hogg, Wiebke
    IMPLANTOLOGIE, 2013, 21 (04): : 355 - 363
  • [3] Dynamic fatigue performance of implant-abutment assemblies with different tightening torque values
    Xia, Dandan
    Lin, Hong
    Yuan, Shenpo
    Bai, Wei
    Zheng, Gang
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (06) : 2143 - 2149
  • [4] Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
    Velez, Jorge
    Pelaez, Jesus
    Lopez-Suarez, Carlos
    Agustin-Panadero, Ruben
    Tobar, Celia
    Suarez, Maria J.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (08) : 1 - 13
  • [5] The Influence of Torque Tightening on the Position Stability of the Abutment in Conical Implant-Abutment Connections
    Hogg, Wiebke Semper
    Zulauf, Kris
    Mehrhof, Juergen
    Nelson, Katja
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (05) : 538 - 541
  • [6] Effects of different torque levels on the implant-abutment interface in a conical internal connection
    Alexandre Gehrke, Sergio
    Shibli, Jamil Awad
    Aramburu Junior, Jaime Sarda
    Mate Sanchez de Val, Jose Eduardo
    Luis Calvo-Girardo, Jose
    Dedavid, Berenice Anina
    BRAZILIAN ORAL RESEARCH, 2016, 30 (01):
  • [7] Influence of abutment materials on the implant-abutment joint stability in internal conical connection type implant systems
    Jo, Jae-Young
    Yang, Dong-Seok
    Huh, Jung-Bo
    Heo, Jae-Chan
    Yun, Mi-Jung
    Jeong, Chang-Mo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (06): : 491 - 497
  • [8] Fracture Resistance of Internal Conical and External Hexagon: Regular and Narrow Implant-Abutment Assemblies
    Prado Naves Carneiro, Thiago de Almeida
    Dietrich, Lia
    Prudente, Marcel Santana
    da Silva Neto, Joao Paulo
    do Prado, Celio Jesus
    de Araujo, Cleudmar Amaral
    das Neves, Flavio Domingues
    IMPLANT DENTISTRY, 2016, 25 (04) : 510 - 514
  • [9] Molecular leakage at implant-abutment connection—in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration
    Sönke Harder
    Birka Dimaczek
    Yaha Açil
    Hendrik Terheyden
    Sandra Freitag-Wolf
    Matthias Kern
    Clinical Oral Investigations, 2010, 14 : 427 - 432
  • [10] Influence of abutment and connection type on implant-abutment connection rigidity: an in vitro study
    Mendes, Teresa Almeida
    Vilhena, Luis Miguel
    Portugal, Jaime
    Carames, Joao
    Ramalho, Amilcar Lopes
    Lopes, Luis Pires
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2022, 63 (03): : 134 - 140