In-office assessment of blood pressure in chronic kidney disease: usual measurement versus automated BpTRU measurement

被引:12
|
作者
O'Shaughnessy, Michelle M. [1 ]
Newman, Christine A. [2 ]
Kinsella, Sinead M. [1 ]
Reddan, Donal N. [1 ]
Lappin, David W. [1 ]
机构
[1] Natl Univ Ireland, Dept Nephrol, Hosp Ground, Galway Univ Hosp, Galway, Ireland
[2] Natl Univ Ireland, Dept Med, Galway, Ireland
关键词
blood pressure measurement; BpTRU; chronic kidney disease; hypertension; renal transplant; WHITE-COAT HYPERTENSION; PROGNOSTIC IMPORTANCE; DIABETIC-NEPHROPATHY; PREVALENCE; RECORDINGS; OUTCOMES; HOME;
D O I
10.1097/MBP.0b013e328346e0db
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives The automated BpTRU device has been shown to improve the accuracy of in-office blood pressure assessment in hypertensive populations. We aimed to determine whether this was also true for patients with chronic kidney disease. Materials and methods We recorded the blood pressure of 80 hypertensive outpatients with chronic kidney disease by usual automated measurement and BpTRU automated measurement. We established whether there were any statistically significant differences in the absolute blood pressure values measured by either method and whether these differences had any impact on the assessment of blood pressure control. Results Systolic and diastolic blood pressures were significantly lower by BpTRU measurement than by usual measurement, by 10.1 +/- 12.2 mmHg (95% confidence interval: 7.4-12.8 mmHg, P<0.001) and 2.8 +/- 10.6 mmHg (95% confidence interval: 0.4-5.1 mmHg, P = 0.02), respectively. Significantly, more patients achieved their blood pressure target of 130/80 mmHg or less by BpTRU measurement than by usual measurement (72.5 vs. 48.8% for systolic blood pressure, P<0.001; 68.8 vs. 61.3% for diastolic blood pressure, P = 0.02). Systolic blood pressures remained significantly lower by BpTRU measurement than by usual measurement in all predefined study subgroups (estimated glomerular filtration rate <30 vs >= 30 ml/min/1.73m(2); transplant vs. nontransplant). We detected more hypotension by BpTRU measurement than by usual measurement. Conclusion Our study suggests that the BpTRU device can negate white coat effect in patients with chronic kidney disease. The use of this device in routine clinical practice could improve the overall accuracy of in-office blood pressure assessment in this high-risk population, minimizing the potential for undertreatment and overtreatment of hypertension. Blood Press Monit 16:124-128 (C) 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 50 条
  • [41] WHITE-COAT BLOOD PRESSURE ELEVATION IS FREQUENT REGARDLESS OF IN-OFFICE MEASUREMENT TECHNIQUE
    Bischoff, Michelle K.
    Doane, John
    Buu, Jenni
    Conroy, Molly
    Penrod, Michael J.
    Stults, Barry
    JOURNAL OF GENERAL INTERNAL MEDICINE, 2018, 33 : S395 - S395
  • [42] Ambulatory blood pressure monitoring versus office blood pressure measurement: Are there sex differences?
    Miladinovic, Aleksandar
    Ajcevic, Milos
    Siveri, Giulia
    Liguori, Laura
    Pascazio, Lorenzo
    Accardo, Agostino
    KNOWLEDGE-BASED AND INTELLIGENT INFORMATION & ENGINEERING SYSTEMS (KSE 2021), 2021, 192 : 2912 - 2918
  • [43] Automated office blood pressure measurement by elderly patients in the waiting room
    Toba, Ayumi
    Ishikawa, Joji
    Suzuki, Ayumi
    Harada, Kazumasa
    BLOOD PRESSURE MONITORING, 2021, 26 (05) : 321 - 327
  • [44] USE OF AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT IN ROUTINE CLINICAL PRACTICE
    Myers, M. G.
    Godwin, M.
    Dawes, M.
    Kiss, A.
    Tobe, S. W.
    Kaczorowski, J.
    JOURNAL OF HYPERTENSION, 2010, 28 : E14 - E15
  • [45] Automated measurement of office, home and ambulatory blood pressure in atrial fibrillation
    Kollias, Anastasios
    Stergiou, George S.
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2014, 41 (01) : 9 - 15
  • [46] Optimum frequency of office blood pressure measurement using an automated sphygmomanometer
    Myers, Martin G.
    Valdivieso, Miguel
    Kiss, Alexander
    BLOOD PRESSURE MONITORING, 2008, 13 (06) : 333 - 338
  • [47] The optimal use of automated office blood pressure measurement in clinical practice
    Andreadis, Emmanuel A.
    Geladari, Charalampia V.
    Angelopoulos, Epameinondas T.
    JOURNAL OF CLINICAL HYPERTENSION, 2020, 22 (04): : 555 - 559
  • [48] Meaningful measurement: developing a measurement system to improve blood pressure control in patients with chronic kidney disease
    Greenberg, Jeffrey O.
    Vakharia, Nirav
    Szent-Gyorgyi, Lara E.
    Desai, Sonali P.
    Turchin, Alexander
    Forman, John
    Bonventre, Joseph V.
    Kachalia, Allen
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2013, 20 (E1) : E97 - E101
  • [49] Clinical Impact Of A 3 Versus 5-minute Delay On Automated Office Blood Pressure Measurement
    Lynn-Green, Erika
    Ishak, Anthony
    Cluett, Jennifer
    Turkson-Ocran, Ruth-Alma N.
    Anderson, Timothy
    Mukamal, Ken J.
    Cohen, Marc L.
    Li, Jonathan
    Juraschek, Stephen P.
    HYPERTENSION, 2022, 79
  • [50] Measurement and treatment of elevated blood pressure in the pediatric patient with chronic kidney disease
    Swinford, RD
    Portman, RJ
    ADVANCES IN CHRONIC KIDNEY DISEASE, 2004, 11 (02) : 143 - 161