In-office assessment of blood pressure in chronic kidney disease: usual measurement versus automated BpTRU measurement

被引:12
|
作者
O'Shaughnessy, Michelle M. [1 ]
Newman, Christine A. [2 ]
Kinsella, Sinead M. [1 ]
Reddan, Donal N. [1 ]
Lappin, David W. [1 ]
机构
[1] Natl Univ Ireland, Dept Nephrol, Hosp Ground, Galway Univ Hosp, Galway, Ireland
[2] Natl Univ Ireland, Dept Med, Galway, Ireland
关键词
blood pressure measurement; BpTRU; chronic kidney disease; hypertension; renal transplant; WHITE-COAT HYPERTENSION; PROGNOSTIC IMPORTANCE; DIABETIC-NEPHROPATHY; PREVALENCE; RECORDINGS; OUTCOMES; HOME;
D O I
10.1097/MBP.0b013e328346e0db
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives The automated BpTRU device has been shown to improve the accuracy of in-office blood pressure assessment in hypertensive populations. We aimed to determine whether this was also true for patients with chronic kidney disease. Materials and methods We recorded the blood pressure of 80 hypertensive outpatients with chronic kidney disease by usual automated measurement and BpTRU automated measurement. We established whether there were any statistically significant differences in the absolute blood pressure values measured by either method and whether these differences had any impact on the assessment of blood pressure control. Results Systolic and diastolic blood pressures were significantly lower by BpTRU measurement than by usual measurement, by 10.1 +/- 12.2 mmHg (95% confidence interval: 7.4-12.8 mmHg, P<0.001) and 2.8 +/- 10.6 mmHg (95% confidence interval: 0.4-5.1 mmHg, P = 0.02), respectively. Significantly, more patients achieved their blood pressure target of 130/80 mmHg or less by BpTRU measurement than by usual measurement (72.5 vs. 48.8% for systolic blood pressure, P<0.001; 68.8 vs. 61.3% for diastolic blood pressure, P = 0.02). Systolic blood pressures remained significantly lower by BpTRU measurement than by usual measurement in all predefined study subgroups (estimated glomerular filtration rate <30 vs >= 30 ml/min/1.73m(2); transplant vs. nontransplant). We detected more hypotension by BpTRU measurement than by usual measurement. Conclusion Our study suggests that the BpTRU device can negate white coat effect in patients with chronic kidney disease. The use of this device in routine clinical practice could improve the overall accuracy of in-office blood pressure assessment in this high-risk population, minimizing the potential for undertreatment and overtreatment of hypertension. Blood Press Monit 16:124-128 (C) 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 50 条
  • [21] Optimising the accuracy of blood pressure monitoring in chronic kidney disease: the utility of BpTRU
    Brothwell, Shona
    Dutton, Mary
    Ferro, Charles
    Stringer, Stephanie
    Cockwell, Paul
    BMC NEPHROLOGY, 2013, 14
  • [22] Brazilian Guidelines for In-office and Out-of-office Blood Pressure Measurement-2023
    Feitosa, Audes Diogenes de Magalhaes
    Barroso, Weimar Kunz Sebba
    Mion Jr, Decio
    Nobre, Fernando
    Mota-Gomes, Marco Antonio
    Jardim, Paulo Cesar Brandao Veiga
    Amodeo, Celso
    Oliveira, Adriana Camargo
    Alessi, Alexandre
    Sousa, Ana Luiza Lima
    Brandao, Andrea Araujo
    Pio-Abreu, Andrea
    Sposito, Andrei C.
    Pierin, Angela Maria Geraldo
    Paiva, Annelise Machado Gomes de
    Spinelli, Antonio Carlos de Souza
    Machado, Carlos Alberto
    Polide-Figueiredo, Carlos Eduardo
    Rodrigues, Cibele Isaac Saad
    Forjaz, Claudia Lucia de Moraes
    Sampaio, Diogo Pereira Santos
    Barbosa, Eduardo Costa Duarte
    Freitas, Elizabete Viana de
    Cestario, Elizabeth do Espirito Santo
    Muxfeldt, Elizabeth Silaid
    Lima Jr, Emilton
    Campana, Erika Maria Goncalves
    Feitosa, Fabiana Gomes Aragao Magalhaes
    Consolim-Colombo, Fernanda Marciano
    Almeida, Fernando Antonio de
    Silva, Giovanio Vieira da
    Moreno Jr, Heitor
    Finimundi, Helius Carlos
    Guimaraes, Isabel Cristina Britto
    Gemelli, Joao Roberto
    Barreto-Filho, Jose Augusto Soares
    Vilelamartin, Jose Fernando
    Ribeiro, Jose Marcio
    Yugar-Toledo, Juan Carlos
    Magalhaes, Lucelia Batista Neves Cunha
    Drager, Luciano F.
    Bortolotto, Luiz Aparecido
    Alves, Marco Antonio de Melo
    Malachias, Marcus Vinicius Bolivar
    Neves, Mario Fritsch Toros
    Santos, Mayara Cedrim
    Dinamarco, Nelson
    Moreira, Osni
    Passarelli Jr, Oswaldo
    Vitorino, Priscila Valverde de Oliveira
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2024, 121 (04)
  • [23] Optimising the accuracy of blood pressure monitoring in chronic kidney disease: the utility of BpTRU
    Shona Brothwell
    Mary Dutton
    Charles Ferro
    Stephanie Stringer
    Paul Cockwell
    BMC Nephrology, 14
  • [24] Comparison of the prognostic significance of blood pressure measurement by unattended automatic office blood pressure and ambulatory blood pressure in subjects with chronic kidney disease
    Seo, J. W.
    Park, S. H.
    Lee, C. J.
    Choi, D. H.
    EUROPEAN HEART JOURNAL, 2018, 39 : 57 - 58
  • [25] Comparison of automated office blood pressure measurement with 24-hour ambulatory blood pressure measurement
    Peeters, Laura E. J.
    van Oortmerssen, Julie A. E.
    Derks, Lieke H.
    den Hertog, Heleen
    Fonville, Susanne
    Verboon, Christine
    Rietdijk, Wim J. R.
    Boersma, Eric
    Koudstaal, Peter J.
    van den Meiracker, Anton H.
    Versmissen, Jorie
    BLOOD PRESSURE, 2022, 31 (01) : 9 - 18
  • [26] Attended versus unattended automated office blood pressure measurement in the diagnosis and treatment of hypertension
    Myers, Martin G.
    Sierra, Alejandro de La
    Roerecke, Michael
    Kaczorowski, Janusz
    JOURNAL OF HYPERTENSION, 2020, 38 (08) : 1407 - 1411
  • [27] Automated Office Blood Pressure Measurement Requires Technology and Implementation
    Boonyasai, Romsai Tony
    JAMA NETWORK OPEN, 2022, 5 (08) : E2232775
  • [28] Automated office blood pressure measurement for routine clinical practice
    Myers, Martin G.
    Nelson, Mark R.
    Head, Geoffrey A.
    MEDICAL JOURNAL OF AUSTRALIA, 2012, 197 (07) : 372 - 373
  • [29] Determination of normal values for automated measurement of blood pressure in the office
    Myers, M. G.
    Valdivieso, M.
    Kiss, A.
    JOURNAL OF HYPERTENSION, 2008, 26 : S485 - S485
  • [30] MINIMUM NUMBER OF READINGS FOR AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT
    Myers, M. G.
    Dawes, M.
    Godwin, M.
    Kaczorowski, J.
    Kiss, A.
    Tobe, S. W.
    JOURNAL OF HYPERTENSION, 2009, 27 : S197 - S197