In-office assessment of blood pressure in chronic kidney disease: usual measurement versus automated BpTRU measurement

被引:12
|
作者
O'Shaughnessy, Michelle M. [1 ]
Newman, Christine A. [2 ]
Kinsella, Sinead M. [1 ]
Reddan, Donal N. [1 ]
Lappin, David W. [1 ]
机构
[1] Natl Univ Ireland, Dept Nephrol, Hosp Ground, Galway Univ Hosp, Galway, Ireland
[2] Natl Univ Ireland, Dept Med, Galway, Ireland
关键词
blood pressure measurement; BpTRU; chronic kidney disease; hypertension; renal transplant; WHITE-COAT HYPERTENSION; PROGNOSTIC IMPORTANCE; DIABETIC-NEPHROPATHY; PREVALENCE; RECORDINGS; OUTCOMES; HOME;
D O I
10.1097/MBP.0b013e328346e0db
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives The automated BpTRU device has been shown to improve the accuracy of in-office blood pressure assessment in hypertensive populations. We aimed to determine whether this was also true for patients with chronic kidney disease. Materials and methods We recorded the blood pressure of 80 hypertensive outpatients with chronic kidney disease by usual automated measurement and BpTRU automated measurement. We established whether there were any statistically significant differences in the absolute blood pressure values measured by either method and whether these differences had any impact on the assessment of blood pressure control. Results Systolic and diastolic blood pressures were significantly lower by BpTRU measurement than by usual measurement, by 10.1 +/- 12.2 mmHg (95% confidence interval: 7.4-12.8 mmHg, P<0.001) and 2.8 +/- 10.6 mmHg (95% confidence interval: 0.4-5.1 mmHg, P = 0.02), respectively. Significantly, more patients achieved their blood pressure target of 130/80 mmHg or less by BpTRU measurement than by usual measurement (72.5 vs. 48.8% for systolic blood pressure, P<0.001; 68.8 vs. 61.3% for diastolic blood pressure, P = 0.02). Systolic blood pressures remained significantly lower by BpTRU measurement than by usual measurement in all predefined study subgroups (estimated glomerular filtration rate <30 vs >= 30 ml/min/1.73m(2); transplant vs. nontransplant). We detected more hypotension by BpTRU measurement than by usual measurement. Conclusion Our study suggests that the BpTRU device can negate white coat effect in patients with chronic kidney disease. The use of this device in routine clinical practice could improve the overall accuracy of in-office blood pressure assessment in this high-risk population, minimizing the potential for undertreatment and overtreatment of hypertension. Blood Press Monit 16:124-128 (C) 2011 Wolters Kluwer Health | Lippincott Williams & Wilkins.
引用
收藏
页码:124 / 128
页数:5
相关论文
共 50 条
  • [31] Fully Automated Blood Pressure Measurement Is the Way to Go in the Office
    Shaughnessy, Allen F.
    AMERICAN FAMILY PHYSICIAN, 2019, 100 (10) : 646 - 646
  • [32] Standardizing Blood Pressure Measurement for Patients with Chronic Kidney Disease in the Outpatient Nephrology Office Setting: A Pilot Study
    Dugan, Chuck
    Montoya, Vicki
    NEPHROLOGY NURSING JOURNAL, 2024, 51 (04) : 337 - 357
  • [33] Office blood pressure versus ambulatory blood pressure measurement in childhood obesity
    van der Heijden, Laila B.
    Groothoff, Jaap W.
    Feskens, Edith J. M.
    Janse, Arieke J.
    BMC PEDIATRICS, 2023, 23 (01)
  • [34] Office blood pressure versus ambulatory blood pressure measurement in childhood obesity
    Laila B van der Heijden
    Jaap W. Groothoff
    Edith JM Feskens
    Arieke J Janse
    BMC Pediatrics, 23
  • [35] Are Automated Blood Pressure Apparatus Reliable? Automated Versus Manual Measurement of Blood Pressure
    Srinivasan, K. Madhan
    Kumar, K. Senthil
    Saraswathi, I.
    Raaju, A. Lokeshwar
    Rao, B. Vishwanatha
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (08) : CC9 - CC12
  • [36] Optimal blood pressure target and measurement in patients with chronic kidney disease
    Kim, Chang Seong
    Choi, Hong Sang
    Bae, Eun Hui
    Kim, Soo Wan
    Ma, Seong Kwon
    KOREAN JOURNAL OF INTERNAL MEDICINE, 2019, 34 (06): : 1181 - 1187
  • [37] Attended Automated Office Blood Pressure Measurement Versus Ambulatory Blood Pressure Monitoring in a Primary Healthcare Setting in Chile
    Michea, Luis
    Toro, Luis
    Alban, Natali
    Contreras, Daisy
    Morgado, Patricia
    Paccot, Melanie
    Escobar, Maria Cristina
    Lorca, Eduardo
    SOUTHERN MEDICAL JOURNAL, 2021, 114 (02) : 63 - 69
  • [38] Repeated office blood pressure measurement by automated device to evaluate blood pressure control
    Crippa, G
    Sverzellati, E
    Venturi, C
    Antoniotti, P
    AMERICAN JOURNAL OF HYPERTENSION, 2003, 16 (05) : 46A - 46A
  • [39] Measurement of Blood Pressure in the Office
    Martin, Catherine A.
    Cameron, James D.
    Chen, Suzi S.
    McGrath, Barry P.
    HYPERTENSION, 2010, 56 (01) : E11 - E11
  • [40] Correspondence: Are Automated Blood Pressure Apparatus Reliable? Automated Versus Manual Measurement of Blood Pressure
    Mondal, Himel
    Mondal, Shaikat
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (12)