Validity and Reliability of a Commercial Force Sensor for the Measurement of Upper Body Strength in Sport Climbing

被引:5
|
作者
Labott, Berit K. [1 ,2 ]
Held, Steffen [2 ]
Wiedenmann, Tim [2 ]
Rappelt, Ludwig [2 ]
Wicker, Pamela [3 ]
Donath, Lars [2 ]
机构
[1] Otto Von Guericke Univ, Inst Sport Sci, Magdeburg, Germany
[2] German Sport Univ Cologne, Dept Intervent Res Exercise Training, Cologne, Germany
[3] Bielefeld Univ, Dept Sports Sci, Bielefeld, Germany
来源
关键词
mountaineering; strength training; finger flexor muscles; performance; maximal strength; FLEXIBILITY CHARACTERISTICS; STATISTICAL-METHODS; FINGER ENDURANCE; ROCK CLIMBERS; ELITE; DETERMINANTS;
D O I
10.3389/fspor.2022.838358
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Recreational and professional climbing is gaining popularity. Thus, valid and reliable infield strength monitoring and testing devices are required. This study aims at assessing the validity as well as within- and between-day reliability of two climbing-specific hanging positions for assessing the maximum force with a new force measurement device. Therefore, 25 experienced male (n = 16) and female (n = 9) climbers (age: 25.5 +/- 4.2 years, height: 176.0 +/- 9.9 cm, weight: 69.7 +/- 14.5 kg, body composition: 11.8 +/- 5.7% body fat, climbing level: 17.5 +/- 3.9 International Rock Climbing Research Association scale) were randomly tested with climbing-specific hang board strength tests (one-handed rung pulling and one-handed bent arm lock-off at 90 degrees). The Tindeq, a load cell-based sensor for assessing different force-related variables, was employed together with a force plate (Kistler Quattro Jump) during both conditions. Data analysis revealed excellent validity for assessment with Tindeq: The intra-class correlation coefficient (ICC) was 0.99 (both positions), while the standard error of the measurement (SEM), coefficient of variation (CV), and limits of agreement (LoA) showed low values. Within day reliability for the assessment with Tindeq was excellent: rung pulling showed an ICC of 0.90 and arm lock-off an ICC of 0.98; between-day reliability was excellent as well: rung pulling indicated an ICC of 0.95 and arm lock-off an ICC of 0.98. Other reliability indicators such as SEM, CV, and LoA were low. The Tindeq progressor can be applied for the cross-sectional and longitudinal climbing strength assessment as this device can detect training-induced changes reliably.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Validity and reliability of Gyko Sport for the measurement of barbell velocity on the bench-press exercise
    Arede, Jorge
    Figueira, Bruno
    Gonzalo-Skok, Oliver
    Leite, Nuno
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 2019, 59 (10): : 1651 - 1658
  • [32] RELIABILITY AND VALIDITY OF A NEW METHOD FOR THE MEASUREMENT OF TOTAL-BODY VOLUME
    KATCH, FI
    HORTOBAGYI, T
    DENAHAN, T
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1989, 60 (03) : 286 - 291
  • [33] Vertical Jump on a Force Plate for Assessing Muscle Strength and Power in Women With Severe Obesity: Reliability, Validity, and Relations With Body Composition
    Bellicha, Alice
    Giroux, Caroline
    Ciangura, Cecile
    Menoux, Diane
    Thoumie, Philippe
    Oppert, Jean-Michel
    Portero, Pierre
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2022, 36 (01) : 75 - 81
  • [34] Validity and reliability of skinfold measurement in assessing body fatness of Chinese children
    Yeung, Daniel Chi-shing
    Hui, Stanley Sai-chuen
    ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION, 2010, 19 (03) : 350 - 357
  • [35] Validity and reliability of strain gauge measurement of volitional quadriceps force in patients with COPD
    Rodrigues, Fernanda Machado
    Demeyer, Heleen
    Hornikx, Miek
    Camillo, Carlos Augusto
    Calik-Kutukcu, Ebru
    Burtin, Chris
    Janssens, Wim
    Troosters, Thierry
    Osadnik, Christian
    CHRONIC RESPIRATORY DISEASE, 2017, 14 (03) : 289 - 297
  • [36] Reliability and Validity of Non-invasive Blood Pressure Measurement System Using Three-Axis Tactile Force Sensor
    Yoo, Sun-Young
    Ahn, Ji-Eun
    Cserey, Gyoergy
    Lee, Hae-Young
    Seo, Jong-Mo
    SENSORS, 2019, 19 (07):
  • [37] Validity and reliability of the Muscular Fitness Test to evaluate body strength-resistance
    Huerta Ojeda, Alvaro
    Galdames Maliqueo, Sergio
    Barahona-Fuentes, Guillermo
    APUNTS-MEDICINA DE L ESPORT, 2020, 55 (208): : 128 - 136
  • [38] Measurement of hip extension strength with a portable device: Description, reliability and validity of a procedure
    Bohannon, Richard W.
    Chu, Johnson
    Portz, Megan
    ISOKINETICS AND EXERCISE SCIENCE, 2015, 23 (04) : 271 - 274
  • [39] Reliability and validity of the Grip-Ball dynamometer for grip-strength measurement
    Chkeir, Aly
    Jaber, Rana
    Hewson, David J.
    Duchene, Jacques
    2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 1996 - 1999
  • [40] VALIDITY AND RELIABILITY OF A BODY-WORN BIOMECHANICAL SENSOR PLATFORM FOR GAIT ANALYSIS
    Argent, R.
    Bourke, A. K.
    Brom, M.
    Caulfield, B.
    Greene, B. R.
    Muaremi, A.
    Praestgaard, J.
    Scotti, C.
    Shabani, S.
    Vallejo, V.
    Walsh, L.
    OSTEOARTHRITIS AND CARTILAGE, 2022, 30 : S148 - S149