Validity and Reliability of a Commercial Force Sensor for the Measurement of Upper Body Strength in Sport Climbing

被引:5
|
作者
Labott, Berit K. [1 ,2 ]
Held, Steffen [2 ]
Wiedenmann, Tim [2 ]
Rappelt, Ludwig [2 ]
Wicker, Pamela [3 ]
Donath, Lars [2 ]
机构
[1] Otto Von Guericke Univ, Inst Sport Sci, Magdeburg, Germany
[2] German Sport Univ Cologne, Dept Intervent Res Exercise Training, Cologne, Germany
[3] Bielefeld Univ, Dept Sports Sci, Bielefeld, Germany
来源
关键词
mountaineering; strength training; finger flexor muscles; performance; maximal strength; FLEXIBILITY CHARACTERISTICS; STATISTICAL-METHODS; FINGER ENDURANCE; ROCK CLIMBERS; ELITE; DETERMINANTS;
D O I
10.3389/fspor.2022.838358
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Recreational and professional climbing is gaining popularity. Thus, valid and reliable infield strength monitoring and testing devices are required. This study aims at assessing the validity as well as within- and between-day reliability of two climbing-specific hanging positions for assessing the maximum force with a new force measurement device. Therefore, 25 experienced male (n = 16) and female (n = 9) climbers (age: 25.5 +/- 4.2 years, height: 176.0 +/- 9.9 cm, weight: 69.7 +/- 14.5 kg, body composition: 11.8 +/- 5.7% body fat, climbing level: 17.5 +/- 3.9 International Rock Climbing Research Association scale) were randomly tested with climbing-specific hang board strength tests (one-handed rung pulling and one-handed bent arm lock-off at 90 degrees). The Tindeq, a load cell-based sensor for assessing different force-related variables, was employed together with a force plate (Kistler Quattro Jump) during both conditions. Data analysis revealed excellent validity for assessment with Tindeq: The intra-class correlation coefficient (ICC) was 0.99 (both positions), while the standard error of the measurement (SEM), coefficient of variation (CV), and limits of agreement (LoA) showed low values. Within day reliability for the assessment with Tindeq was excellent: rung pulling showed an ICC of 0.90 and arm lock-off an ICC of 0.98; between-day reliability was excellent as well: rung pulling indicated an ICC of 0.95 and arm lock-off an ICC of 0.98. Other reliability indicators such as SEM, CV, and LoA were low. The Tindeq progressor can be applied for the cross-sectional and longitudinal climbing strength assessment as this device can detect training-induced changes reliably.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Validation and Reliability of a Novel Test of Upper Body Isometric Strength
    Bellar, David
    Marcus, Lena
    Judge, Lawrence W.
    JOURNAL OF HUMAN KINETICS, 2015, 47 (01) : 189 - 195
  • [23] Validity and Intra Rater Reliability of a New Device for Tongue Force Measurement
    Diaz-Saez, Marta Carlota
    Beltran-Alacreu, Hector
    Gil-Castillo, Javier
    Navarro-Fernandez, Gonzalo
    Cebrian Carretero, Jose Luis
    Gil-Martinez, Alfonso
    INTERNATIONAL JOURNAL OF INTERACTIVE MULTIMEDIA AND ARTIFICIAL INTELLIGENCE, 2023, 8 (02): : 60 - 68
  • [24] VALIDITY OF FIELD-TESTS OF UPPER-BODY MUSCULAR STRENGTH
    PATE, RR
    BURGESS, ML
    WOODS, JA
    ROSS, JG
    BAUMGARTNER, T
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 1993, 64 (01) : 17 - 24
  • [25] The validity and reliability of the Functional Strength Measurement (FSM) in children with intellectual disabilities
    Aertssen, W. F. M.
    Steenbergen, B.
    Smits-Engelsman, B. C. M.
    JOURNAL OF INTELLECTUAL DISABILITY RESEARCH, 2018, 62 (08) : 719 - 729
  • [26] MEASUREMENT OF GRIP STRENGTH - VALIDITY AND RELIABILITY OF THE SPHYGMOMANOMETER AND JAMAR GRIP DYNAMOMETER
    HAMILTON, GF
    MCDONALD, C
    CHENIER, TC
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (05): : 215 - 219
  • [27] Reliability and Validity of the Martin Vigorimeter for Grip Strength Measurement in Korean Adults
    Lee, Jeong Kil
    Jung, Meesun
    Lee, Han Byul
    Chung, Hyung Jin
    Lee, Seung Hoo
    CLINICS IN ORTHOPEDIC SURGERY, 2024, 16 (04) : 610 - 619
  • [28] Validity and Reliability of upper limb muscles strength measurements by handheld dynamometer in COPD
    Beaumont, M.
    Peran, L.
    Berriet, A.
    Keller, R.
    Le Ber, C.
    EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [29] Validity and Reliability of Evaluating Abdominal Strength Utilizing Electromyography and Isometric Force Production
    Glenn, Jordan M.
    Edwards, Abigail
    Galey, Madeline
    Brown, Barry
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 604 - 604
  • [30] Upper-Body Isometric Horizontal Strength in Professional Game Sport Athletes
    Reichert, Lukas
    Wieland, Bjoern
    Fleddermann, Marie-Therese
    Zentgraf, Karen
    JOURNAL OF SPORT & EXERCISE PSYCHOLOGY, 2022, 44 : S50 - S50