Validity and Intra Rater Reliability of a New Device for Tongue Force Measurement

被引:3
|
作者
Diaz-Saez, Marta Carlota [1 ,2 ]
Beltran-Alacreu, Hector [2 ,3 ]
Gil-Castillo, Javier [4 ]
Navarro-Fernandez, Gonzalo [1 ,2 ]
Cebrian Carretero, Jose Luis [5 ]
Gil-Martinez, Alfonso [1 ,2 ,6 ]
机构
[1] Univ Autonoma Madrid, Ctr Super Estudios Univ La Salle, Physiotherapy Dept, Madrid, Spain
[2] Ctr Super Estudios Univ La Salle, CranioSPain Res Grp, Madrid 28023, Spain
[3] Univ Castilla La Mancha, Fac Phys Therapy & Nursing, Toledo Physiotherapy Res Grp GIFTO, Ciudad Real, Spain
[4] CSIC, Inst Cajal, Neurorehabil Grp, Madrid, Spain
[5] Hosp Univ La Paz, Maxilofacial & Oral Surg Dept, Madrid, Spain
[6] Hosp La Paz, Inst Hlth Res IdiPaz, Unit Physiotherapy, Madrid, Spain
关键词
Device; Reliability; Temporomandibular Disorders; Tongue Force; Validity; ORAL PERFORMANCE INSTRUMENT; CORRELATION-COEFFICIENT; HAND STRENGTH; SAMPLE-SIZE; PRESSURE; ENDURANCE; MOVEMENTS; STANDARD; AGREEMENT; SENSOR;
D O I
10.9781/ijimai.2022.02.001
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Background. The tongue is made up of multiple muscles both extrinsic and intrinsic. The hyoid, jaw and maxillary complex contain the tongue, which hangs between these structures forming an important biomechanical system. This organ has to work in coordination with craniofacial structures to ensure normal orofacial functioning. There are different devices on the market for tongue force measurement. However, they are not accessible for patients due to their size and very high prices. Likewise, other devices have not yet carried out validity and reliability studies. The purpose of this study was to validate a new device proving that it is accurate compared to the algometer. Moreover, the study wanted to determine the intra-rater reliability of a protocol to assess the maximum tongue force in asymptomatic subjects. Material and methods. This is an observational-longitudinal study with repeated measurements. A prototype device was developed specifically for this study to measure tongue force through force-sensitive resistor sensors. The prototype system was equipped with a device to perform and transmit the measurement and a C++ programming software in the computer to take data from the session. Different formulas were made to calibrate the system. For validity, the force measured by the prototype and the algometer was compared. For intra-rater reliability, 29 asymptomatic Spanish subjects were recruited, and a standardized protocol was carried out for the tests. Results. Experiments to assess validity showed a strong correlation (r>0.97) and an excellent reliability (ICC>0.90) between devices. On the other hand, the intra-rater reliability analysis showed an excellent ICC (0.93) with a 95% CI of 0.86 to 0.97 and a MDC90 of 6.26N. Conclusion. We demonstrated good validity values and high intra-rater reliability for the prototype device for the maximum tongue force.
引用
收藏
页码:60 / 68
页数:9
相关论文
共 50 条
  • [1] Examination of inter-rater and intra-rater reliability during retentive force measurement of different clasps using the developed small-sized retentive force measurement device
    Hitoshi Akiyama
    Maiko Sakamoto
    Ryoichi Akama
    Jun Takei
    BMC Oral Health, 20
  • [2] Examination of inter-rater and intra-rater reliability during retentive force measurement of different clasps using the developed small-sized retentive force measurement device
    Akiyama, Hitoshi
    Sakamoto, Maiko
    Akama, Ryoichi
    Takei, Jun
    BMC ORAL HEALTH, 2020, 20 (01)
  • [3] Validity and reliability of a new ankle dorsiflexion measurement device
    Gatt, Alfred
    Chockalingam, Nachiappan
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2013, 37 (04) : 289 - 297
  • [4] Test validity and intra-rater reliability in the measurement of scapular position sense in asymptomatic young adults
    Deng, Huei-Ru
    Shih, Yi-Fen
    MANUAL THERAPY, 2015, 20 (03) : 503 - 507
  • [5] Reliability and Validity of a New Eccentric Hamstring Strength Measurement Device
    Lodge, Clare
    Tobin, Diarmuid
    O'Rourke, Brian
    Thorborg, Kristian
    ARCHIVES OF REHABILITATION RESEARCH AND CLINICAL TRANSLATION, 2020, 2 (01)
  • [6] Validity and reliability of a new in vivo ankle stiffness measurement device
    Zinder, Steven M.
    Granata, Kevin P.
    Padua, Darin A.
    Gansneder, Bruce M.
    JOURNAL OF BIOMECHANICS, 2007, 40 (02) : 463 - 467
  • [7] Reliability and Responsiveness of a Novel Device to Evaluate Tongue Force
    Diaz-Saez, Marta Carlota
    Gil-Martinez, Alfonso
    Gadotti, Inae Caroline
    Navarro-Fernandez, Gonzalo
    Gil-Castillo, Javier
    Beltran-Alacreu, Hector
    LIFE-BASEL, 2023, 13 (05):
  • [8] Validation of Inter-Rater and Intra-Rater Reliability of Remote Dielectric Sensing Measurement
    Hori, Masakazu
    Imamura, Teruhiko
    Fukuo, Atsuko
    Fukui, Takuya
    Koi, Takatoshi
    Ueno, Yohei
    Onoda, Hiroshi
    Tanaka, Shuhei
    Ushijima, Ryuichi
    Sobajima, Mitsuo
    Fukuda, Nobuyuki
    Ueno, Hiroshi
    Kinugawa, Koichiro
    INTERNATIONAL HEART JOURNAL, 2022, 63 (01) : 73 - 76
  • [9] The reliability and validity of a first ray measurement device
    Glasoe, WM
    Yack, HJ
    Saltzman, CL
    FOOT & ANKLE INTERNATIONAL, 2000, 21 (03) : 240 - 246
  • [10] VALIDITY, INTRA-RATER RELIABILITY AND NORMATIVE DATA OF THE NEUROFLEXORTM DEVICE TO MEASURE SPASTICITY OF THE ANKLE PLANTAR FLEXORS AFTER STROKE
    Pennati, Gaia Valentina
    Carment, Loic
    Godbolt, Alison K.
    Plantin, Jeanette
    Borg, Jorgen
    Lindberg, Pavel G.
    JOURNAL OF REHABILITATION MEDICINE, 2023, 55