Validity and Intra Rater Reliability of a New Device for Tongue Force Measurement

被引:3
|
作者
Diaz-Saez, Marta Carlota [1 ,2 ]
Beltran-Alacreu, Hector [2 ,3 ]
Gil-Castillo, Javier [4 ]
Navarro-Fernandez, Gonzalo [1 ,2 ]
Cebrian Carretero, Jose Luis [5 ]
Gil-Martinez, Alfonso [1 ,2 ,6 ]
机构
[1] Univ Autonoma Madrid, Ctr Super Estudios Univ La Salle, Physiotherapy Dept, Madrid, Spain
[2] Ctr Super Estudios Univ La Salle, CranioSPain Res Grp, Madrid 28023, Spain
[3] Univ Castilla La Mancha, Fac Phys Therapy & Nursing, Toledo Physiotherapy Res Grp GIFTO, Ciudad Real, Spain
[4] CSIC, Inst Cajal, Neurorehabil Grp, Madrid, Spain
[5] Hosp Univ La Paz, Maxilofacial & Oral Surg Dept, Madrid, Spain
[6] Hosp La Paz, Inst Hlth Res IdiPaz, Unit Physiotherapy, Madrid, Spain
关键词
Device; Reliability; Temporomandibular Disorders; Tongue Force; Validity; ORAL PERFORMANCE INSTRUMENT; CORRELATION-COEFFICIENT; HAND STRENGTH; SAMPLE-SIZE; PRESSURE; ENDURANCE; MOVEMENTS; STANDARD; AGREEMENT; SENSOR;
D O I
10.9781/ijimai.2022.02.001
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Background. The tongue is made up of multiple muscles both extrinsic and intrinsic. The hyoid, jaw and maxillary complex contain the tongue, which hangs between these structures forming an important biomechanical system. This organ has to work in coordination with craniofacial structures to ensure normal orofacial functioning. There are different devices on the market for tongue force measurement. However, they are not accessible for patients due to their size and very high prices. Likewise, other devices have not yet carried out validity and reliability studies. The purpose of this study was to validate a new device proving that it is accurate compared to the algometer. Moreover, the study wanted to determine the intra-rater reliability of a protocol to assess the maximum tongue force in asymptomatic subjects. Material and methods. This is an observational-longitudinal study with repeated measurements. A prototype device was developed specifically for this study to measure tongue force through force-sensitive resistor sensors. The prototype system was equipped with a device to perform and transmit the measurement and a C++ programming software in the computer to take data from the session. Different formulas were made to calibrate the system. For validity, the force measured by the prototype and the algometer was compared. For intra-rater reliability, 29 asymptomatic Spanish subjects were recruited, and a standardized protocol was carried out for the tests. Results. Experiments to assess validity showed a strong correlation (r>0.97) and an excellent reliability (ICC>0.90) between devices. On the other hand, the intra-rater reliability analysis showed an excellent ICC (0.93) with a 95% CI of 0.86 to 0.97 and a MDC90 of 6.26N. Conclusion. We demonstrated good validity values and high intra-rater reliability for the prototype device for the maximum tongue force.
引用
收藏
页码:60 / 68
页数:9
相关论文
共 50 条
  • [31] Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion
    Quek, June
    Brauer, Sandra G.
    Treleaven, Julia
    Pua, Yong-Hao
    Mentiplay, Benjamin
    Clark, Ross Allan
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11
  • [32] Validity and intra-rater reliability of MyJump app on iPhone 6s in jump performance
    Stanton, Robert
    Wintour, Sally-Anne
    Kean, Crystal O.
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2017, 20 (05) : 518 - 523
  • [33] Validity and intra-rater reliability of an Android phone application to measure cervical range-of-motion
    June Quek
    Sandra G Brauer
    Julia Treleaven
    Yong-Hao Pua
    Benjamin Mentiplay
    Ross Allan Clark
    Journal of NeuroEngineering and Rehabilitation, 11
  • [34] Validity and reliability of a kinematic device for measuring the force developed during squatting
    Rahmani, A
    Dalleau, G
    Viale, F
    Hautier, CA
    Lacour, JR
    JOURNAL OF APPLIED BIOMECHANICS, 2000, 16 (01) : 26 - 35
  • [36] Content Validity Index and Intra- and Inter-Rater Reliability of a New Muscle Strength/Endurance Test Battery for Swedish Soldiers
    Larsson, Helena
    Tegern, Matthias
    Monnier, Andreas
    Skoglund, Jorgen
    Helander, Charlotte
    Persson, Emelie
    Malm, Christer
    Broman, Lisbet
    Aasa, Ulrika
    PLOS ONE, 2015, 10 (07):
  • [37] Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®
    Mihalinec, Katja
    Martinez-Cepa, Carmen B.
    Zuil-Escobar, Juan C.
    Kejzar, Natasa
    Vauhnik, Renata
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [38] Intra-Rater and Inter-Rater Reliability of Tongue Coating Diagnosis in Traditional Chinese Medicine Using Smartphones: Quasi-Delphi Study
    Wang, Zhi Chun
    Zhang, Shi Ping
    Yuen, Pong Chi
    Chan, Kam Wa
    Chan, Yi Yi
    Cheung, Chun Hoi
    Chow, Chi Ho
    Chua, Ka Kit
    Hu, Jun
    Hu, Zhichao
    Lao, Beini
    Leung, Chun Chuen
    Li, Hong
    Zhong, Linda
    Liu, Xusheng
    Liu, Yulong
    Liu, Zhenjie
    Lun, Xin
    Mo, Wei
    Siu, Sheng Yuen
    Xiong, Zhoujian
    Yeung, Wing Fai
    Zhang, Run Yun
    Zhang, Xuebin
    JMIR MHEALTH AND UHEALTH, 2020, 8 (07):
  • [39] Measuring Essay Assessment: Intra-rater and Inter-rater Reliability
    Kayapinar, Ulas
    EURASIAN JOURNAL OF EDUCATIONAL RESEARCH, 2014, (57): : 113 - 135
  • [40] Validity and intra-session reliability of a low-cost device for assessing isometric mid-thigh pull force
    Couto, Diego
    Cunha, Rafael
    Lage, Victor
    Rocha Jr, Valdinar
    Santos, Wanderson
    Ferreira Jr, Joao B.
    Tufano, James
    Vieira, Amilton
    HUMAN MOVEMENT, 2023, 24 (02) : 52 - 58