Examination of inter-rater and intra-rater reliability during retentive force measurement of different clasps using the developed small-sized retentive force measurement device

被引:0
|
作者
Akiyama, Hitoshi [1 ]
Sakamoto, Maiko [1 ]
Akama, Ryoichi [2 ]
Takei, Jun [2 ]
机构
[1] Nippon Dent Univ Hosp, Gen Dent, 2-3-16 Chiyoda Ku, Fujimi, Tokyo 1028158, Japan
[2] Nippon Dent Univ Hosp, Lab Room, 2-3-16 Chiyoda Ku, Fujimi, Tokyo 1028158, Japan
基金
日本学术振兴会;
关键词
Abutment tooth; Retentive force; Removable partial denture; Clasp; Intraclass correlation coefficient; COBALT-CHROMIUM; ACETAL RESIN; TITANIUM; DEFORMATION;
D O I
10.1186/s12903-020-01215-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background The design process of a removable partial denture (RPD) consists of rests, major connectors, minor connectors, denture base, and retainer. The abutment tooth contour determines the location of the retention portion of the clasp at the retention areas. The load capacity of the clasp depends on various factors such as type, the position of a clasp, tooth position, clasp length, and pullout location. As a general rule, the amount of retention required to dislodge the RPD from the supporting structure should always be the minimum necessary to resist reasonable dislodging forces. Excessive force from the clasps may cause many problems. Although there are many reports on the retentive force of cast clasps using large devices, it has not been possible to measure it using simple devices until now. Method The purpose of the present study is to develop a small-sized retentive force measurement device that can easily measure the retentive force of a clasp used for an RPD. It is to examine inter-rater and intra-rater reliability. A small-sized retentive force measurement device that can be easily measured in the laboratory has been developed. Using commercially available hard plaster cast, a skilled dental technician has made 10 types of cast clasps used in clinical practice using conventional techniques. Three assessors measured the retentive force of 10 types of cast clasps. To confirm the reliability, the intra-class correlation coefficients ICC (1,1) and ICC (1,3) of the 3 assessors were calculated, and the reliability within the assessor was examined. The inter-class correlation coefficients ICC (3,1) and ICC (3,3) were calculated, and the reliability of the assessors was examined. Result The intra-class correlation coefficients of 3 assessors are as follows: assessor 1 has ICC (1,1) = 0.971, ICC (1,3) = 0.990, assessor 2 has ICC (1,1) = 0.967, ICC (1,3) = 0.989, assessor 3 has ICC (1,1) = 0.962, ICC (1,3) = 0.987. The inter-class correlation coefficients of 3 assessors are as follows: ICC (3,1) = 0.993, ICC (3,3) = 0.998. From the evaluation standard of the intraclass correlation coefficients of reliability value by ICC, it was evaluated as almost perfect and high reproducibility was confirmed. Conclusion The developed small-sized retentive force measurement device has reproducibility within and between the assessors.
引用
收藏
页数:7
相关论文
共 22 条
  • [1] Examination of inter-rater and intra-rater reliability during retentive force measurement of different clasps using the developed small-sized retentive force measurement device
    Hitoshi Akiyama
    Maiko Sakamoto
    Ryoichi Akama
    Jun Takei
    BMC Oral Health, 20
  • [2] Validation of Inter-Rater and Intra-Rater Reliability of Remote Dielectric Sensing Measurement
    Hori, Masakazu
    Imamura, Teruhiko
    Fukuo, Atsuko
    Fukui, Takuya
    Koi, Takatoshi
    Ueno, Yohei
    Onoda, Hiroshi
    Tanaka, Shuhei
    Ushijima, Ryuichi
    Sobajima, Mitsuo
    Fukuda, Nobuyuki
    Ueno, Hiroshi
    Kinugawa, Koichiro
    INTERNATIONAL HEART JOURNAL, 2022, 63 (01) : 73 - 76
  • [3] Inter-rater and intra-rater reliability of Kinovea software for measurement of shoulder range of motion
    Reham M. Abd Elrahim
    Eman A. Embaby
    Mohamed F. Ali
    Ragia M. Kamel
    Bulletin of Faculty of Physical Therapy, 2016, 21 (2) : 80 - 87
  • [4] Evaluation of the inter-rater and intra-rater reliability of a protocol for the measurement of foot-transmitted vibration
    Vance, Brandon
    Goggins, Katie A.
    Godwin, Alison
    Oddson, Bruce E.
    Eger, Tammy R.
    THEORETICAL ISSUES IN ERGONOMICS SCIENCE, 2021, 22 (02) : 219 - 236
  • [5] Inter-rater and intra-rater reliability of subchondral bone and cartilage thickness measurement from MRI
    McGibbon, CA
    MAGNETIC RESONANCE IMAGING, 2003, 21 (07) : 707 - 714
  • [6] Validity and Intra Rater Reliability of a New Device for Tongue Force Measurement
    Diaz-Saez, Marta Carlota
    Beltran-Alacreu, Hector
    Gil-Castillo, Javier
    Navarro-Fernandez, Gonzalo
    Cebrian Carretero, Jose Luis
    Gil-Martinez, Alfonso
    INTERNATIONAL JOURNAL OF INTERACTIVE MULTIMEDIA AND ARTIFICIAL INTELLIGENCE, 2023, 8 (02): : 60 - 68
  • [7] Novel Ultrasound Anatomical Measurement of the Deep Transverse Metatarsal Ligament: An Intra-Rater Reliability and Inter-Rater Concordance Study
    del Mar Ruiz-Herrera, Maria
    Marcos-Tejedor, Felix
    Aldana-Caballero, Alberto
    Calvo-Lobo, Cesar
    Rodriguez-Sanz, David
    Moroni, Simone
    Konschake, Marko
    Mohedano-Moriano, Alicia
    Aceituno-Gomez, Javier
    Criado-alvarez, Juan Jose
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (09)
  • [8] Measurement of glenohumeral joint translation using real-time ultrasound imaging: A physiotherapist and sonographer intra-rater and inter-rater reliability study
    Rathi, Sangeeta
    Taylor, Nicholas F.
    Gee, Jamie
    Green, Rodney A.
    MANUAL THERAPY, 2016, 26 : 110 - 116
  • [9] Spondylolisthesis: Intra-rater and inter-rater reliabilities of radiographic sagittal spinopelvic parameters using standard picture archiving and communication system measurement tools
    Montgomery R.A.
    Hresko M.T.
    Kalish L.A.
    Gold M.
    Li Y.
    Haus B.
    Glotzbecker M.
    Berthonnaud E.
    Spine Deformity, 2013, 1 (6) : 412 - 418
  • [10] Three-dimensional intra-rater and inter-rater reliability during a posed smile using a video-based motion analyzing system
    Mishima, Katsuaki
    Umeda, Hirotsugu
    Nakano, Asuka
    Shiraishi, Ruriko
    Hori, Sayaka
    Ueyama, Yoshiya
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (05) : 428 - 431