Novel Ultrasound Anatomical Measurement of the Deep Transverse Metatarsal Ligament: An Intra-Rater Reliability and Inter-Rater Concordance Study

被引:2
|
作者
del Mar Ruiz-Herrera, Maria [1 ]
Marcos-Tejedor, Felix [2 ]
Aldana-Caballero, Alberto [3 ]
Calvo-Lobo, Cesar [4 ]
Rodriguez-Sanz, David [4 ]
Moroni, Simone [5 ]
Konschake, Marko [6 ]
Mohedano-Moriano, Alicia [2 ]
Aceituno-Gomez, Javier [7 ,8 ]
Criado-alvarez, Juan Jose [2 ,9 ]
机构
[1] Maria Mar Ruiz Clin, 13600 Alcazar San Juan, Ciudad Real, Spain
[2] Univ Castilla La Mancha, Fac Hlth Sci, Dept Med Sci, Toledo 45600, Spain
[3] Univ Castilla La Mancha, Fac Hlth Sci, Dept Nursing Physiotherapy & Occupat Therapy, Toledo 45600, Spain
[4] Univ Complutense Madrid, Fac Nursing Physioterapy & Podiatry, Madrid 28040, Spain
[5] Cent Univ Catalunya UVic Ucc, Univ Vic, Fac Hlth Sci Manresa, Dept Podiatry, Barcelona 08500, Spain
[6] Med Univ Innsbruck MUI, Inst Clin & Funct Anat, Dept Anat Histol & Embryol, A-6020 Innsbruck, Austria
[7] Hlth Serv Castilla La Mancha, Management Integrated Assistance Talavera Reina, Toledo 45600, Spain
[8] Univ Castilla La Mancha, Fac Nursing & Physiotherapy, Dept Nursing Physiotherapy & Occupat Therapy, Toledo 45600, Spain
[9] Inst Hlth Sci, Dept Hlth, Toledo 45600, Spain
关键词
Morton's Neuroma; deep transverse metatarsal ligament; ultrasound; concordance; SAMPLE-SIZE REQUIREMENTS; UNDERGRADUATE STUDENTS; MORTONS; ULTRASONOGRAPHY;
D O I
10.3390/jcm11092553
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Insufficient space below the Deep Transverse Metatarsal Ligament (DTML) could be an etiological factor for Morton's Neuroma (MN). To date, there is a lack of studies measuring the space below the DTML. For this reason, this study assesses the intra- and inter-rater concordance and reproducibility of measurements of the space below the DTML between the third and the fourth metatarsal heads (M3 and M4) using ultrasound imaging to assess and verify the reliability and reproducibility of measurements of the space under the DTML. Forty feet from twenty patients were examined using ultrasound by three trained evaluators at two different times. The two measurements taken on each foot were: base (b)-distance between M3 and M4, and height (h)-distance between the DTML and the plantar skin surface. This was a quantitative, observational, analytical study. The concordance rate between observers for measurements of height and base were 98.5% and 99.5%, respectively. The mean area obtained of the space was 54.6 mm(2) and 57.2 mm(2) for both the left and right foot (p > 0.05). Reproducibility over time calculated in pre- and post-measurements showed an intraclass correlation coefficient of 1.00 (95%CI: 0.99-1.00), which leads us to conclude that the measurements are perfectly reproducible. Both measurements (height and base) of the space under the DTML, performed by ultrasound, are reliable and reproducible.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Validation of Inter-Rater and Intra-Rater Reliability of Remote Dielectric Sensing Measurement
    Hori, Masakazu
    Imamura, Teruhiko
    Fukuo, Atsuko
    Fukui, Takuya
    Koi, Takatoshi
    Ueno, Yohei
    Onoda, Hiroshi
    Tanaka, Shuhei
    Ushijima, Ryuichi
    Sobajima, Mitsuo
    Fukuda, Nobuyuki
    Ueno, Hiroshi
    Kinugawa, Koichiro
    INTERNATIONAL HEART JOURNAL, 2022, 63 (01) : 73 - 76
  • [2] Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®
    Mihalinec, Katja
    Martinez-Cepa, Carmen B.
    Zuil-Escobar, Juan C.
    Kejzar, Natasa
    Vauhnik, Renata
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [3] Measuring Essay Assessment: Intra-rater and Inter-rater Reliability
    Kayapinar, Ulas
    EURASIAN JOURNAL OF EDUCATIONAL RESEARCH, 2014, (57): : 113 - 135
  • [4] Intra-rater and inter-rater reliability of the standardized ultrasound protocol for assessing subacromial structures
    Hougs Kjaer, Birgitte
    Ellegaard, Karen
    Wieland, Ina
    Warming, Susan
    Juul-Kristensen, Birgit
    PHYSIOTHERAPY THEORY AND PRACTICE, 2017, 33 (05) : 398 - 409
  • [5] Inter-rater and intra-rater reliability of Kinovea software for measurement of shoulder range of motion
    Reham M. Abd Elrahim
    Eman A. Embaby
    Mohamed F. Ali
    Ragia M. Kamel
    Bulletin of Faculty of Physical Therapy, 2016, 21 (2) : 80 - 87
  • [6] Optoelectronic plethysmography: Intra-rater and inter-rater reliability in healthy subjects
    Vieira, Danielle S. R.
    Hoffman, Mariana
    Pereira, Danielle A. G.
    Britto, Raquel R.
    Parreira, Veronica F.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2013, 189 (03) : 473 - 476
  • [7] INTER-RATER AND INTRA-RATER RELIABILITY OF UROFLOWMETRY INTERPRETATION IN ADULT WOMEN
    Rickey, Leslie M.
    Mueller, Elizabeth R.
    Newman, Diane K.
    Markland, Alayne D.
    Falke, Chloe
    Rudser, Kyle
    Lukacz, Emily S.
    JOURNAL OF UROLOGY, 2023, 209 : E519 - E519
  • [8] Inter-rater and intra-rater reliability of the airway diameter measured by sonography
    Gómez-Tamayo J.C.
    Puerta-Guarín J.I.
    Rojas-Camejo C.M.
    Caicedo J.P.
    Calvache J.A.
    Journal of Ultrasound, 2018, 21 (1) : 35 - 40
  • [9] INTER-RATER, INTRA-RATER, AND INTER-MACHINE RELIABILITY OF QUANTITATIVE ULTRASOUND MEASUREMENTS OF THE PATELLAR TENDON
    Gellhorn, Alfred C.
    Carlson, M. Jake
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (05): : 791 - 796
  • [10] INTER-RATER AND INTRA-RATER RELIABILITY OF BRIEF PSYCHIATRIC RATING SCALE
    FLEMENBAUM, A
    ZIMMERMANN, RL
    PSYCHOLOGICAL REPORTS, 1973, 32 (03) : 783 - 792