Ultrasound-based computer navigation of the acetabular component: a feasibility study

被引:4
|
作者
Wassilew, Georgi I. [1 ]
Heller, Markus O. [2 ,3 ]
Hasart, Olaf [1 ]
Perka, Carsten [1 ]
Suedhoff, Ingrid [4 ]
Janz, Viktor [1 ]
Duda, Georg N. [2 ,3 ]
Koenig, Christian [2 ]
机构
[1] Charite, Ctr Musculoskeletal Surg, Dept Orthoped, D-10117 Berlin, Germany
[2] Charite, Ctr Sports Sci & Sports Med Berlin CSSB, Ctr Musculoskeletal Surg, D-10117 Berlin, Germany
[3] Charite, Ctr Sports Sci & Sports Med Berlin CSSB, Julius Wolff Inst, D-10117 Berlin, Germany
[4] Aesculap AG, Tuttlingen, Germany
关键词
Ultrasound; Computer navigation; Acetabular component; Cadaver; Accuracy; TOTAL HIP-ARTHROPLASTY; CUP PLACEMENT; PELVIC PLANE; REPLACEMENT; ORIENTATION; DISLOCATION; ACCURACY; POSITION; ANTEVERSION; MOTION;
D O I
10.1007/s00402-011-1412-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction This feasibility study investigated the accuracy of anterior pelvic reference plane (APP) registration and acetabular cup orientation in two cadavers with different BMIs. Method Five observers each registered the APP five times in the 2 cadavers (BMIs: 32 kg/m(2) and 25 kg/m(2)) using an ultrasound-based navigation system. By comparison against the CT-derived reference landmarks, the errors in determining the individual landmarks defining the APP, as well as the resulting errors in the orientation of the APP and the acetabular cup orientation were determined. Results Across all measurements obtained with the ultrasound navigation system, the errors in rotation and version in determining the APP were 0.5 degrees +/- 1.0 degrees and -0.4 degrees +/- 2.0 degrees, respectively. The cup abduction and anteversion errors determined from all measurements of the five investigators for both cadavers together were -0.1 degrees +/- 1.0 degrees and -0.4 degrees +/- 2.7 degrees, respectively. The data further demonstrated a high reproducibility of the measurements for the resulting cup adduction and anteversion angle. Conclusion Our preliminary results confirm that ultrasound navigation is a highly accurate tool that allows a reproducible registration of the APP and thereby enables accurate and precise intraoperative determination of the acetabular cup orientation also in patients with increased BMI.
引用
收藏
页码:517 / 525
页数:9
相关论文
共 50 条
  • [31] Feasibility of ultrasound-based measurement of dorsal scaphoid displacement: A 3D-model study
    Laber, R.
    Reissner, L.
    Nagy, L.
    Schweizer, A.
    HAND SURGERY & REHABILITATION, 2021, 40 (05): : 595 - 601
  • [32] Ultrasound-based navigation for open liver surgery using active liver tracking
    Smit, Jasper N.
    Kuhlmann, Koert F. D.
    Ivashchenko, Oleksandra, V
    Thomson, Bart R.
    Lango, Thomas
    Kok, Niels F. M.
    Fusaglia, Matteo
    Ruers, Theo J. M.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2022, 17 (10) : 1765 - 1773
  • [33] Standalone ultrasound-based highly visualized volumetric spine imaging for surgical navigation
    Hu, Xinben
    Liu, Tianjian
    Zhang, Zhengyuan
    Xiao, Xuan
    Chen, Lin
    Wei, Gao
    Wang, Yunjiang
    Yang, Keji
    Jin, Haoran
    Zhu, Yongjian
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [34] Ultrasound-based navigation for open liver surgery using active liver tracking
    Jasper N. Smit
    Koert F. D. Kuhlmann
    Oleksandra V. Ivashchenko
    Bart R. Thomson
    Thomas Langø
    Niels F. M. Kok
    Matteo Fusaglia
    Theo J. M. Ruers
    International Journal of Computer Assisted Radiology and Surgery, 2022, 17 : 1765 - 1773
  • [35] Ultrasound-based navigated pedicle screw insertion without intraoperative radiation: feasibility study on porcine cadavers
    Gueziri, Houssem-Eddine
    Georgiopoulos, Miltiadis
    Santaguida, Carlo
    Collins, D. Louis
    SPINE JOURNAL, 2022, 22 (08): : 1408 - 1417
  • [36] Ultrasound-based localization
    Kuban, DA
    Dong, L
    Cheung, R
    Strom, E
    De Crevoisier, R
    SEMINARS IN RADIATION ONCOLOGY, 2005, 15 (03) : 180 - 191
  • [37] 4D Ultrasound-Based Knee Joint Atlas for Robotic Knee Arthroscopy: A Feasibility Study
    Antico, Maria
    Sasazawa, Fumio
    Takeda, Yu
    Jaiprakash, Anjali T.
    Wille, Marie-Luise
    Pandey, Ajay K.
    Crawford, Ross
    Fontanarosa, Davide
    IEEE ACCESS, 2020, 8 : 146331 - 146341
  • [38] An Ultrasound-Based Computer-Aided Diagnosis Tool for Steatosis Detection
    Ribeiro, Ricardo T.
    Marinho, Rui Tato
    Miguel Sanches, J.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2014, 18 (04) : 1397 - 1403
  • [39] Imageless navigation for insertion of the acetabular component in total hip arthroplasty -: Is it as accurate as CT-based navigation?
    Kalteis, T
    Handel, A
    Bäthis, H
    Perlick, L
    Tingart, M
    Grifka, J
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02): : 163 - 167
  • [40] Imaging and Navigation Measurement of Acetabular Component Position in THA
    Wan, Zhinian
    Malik, Aamer
    Jaramaz, Branislav
    Chao, Lisa
    Dorr, Lawrence D.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (01) : 32 - 42