Ultrasound-based computer navigation of the acetabular component: a feasibility study

被引:4
|
作者
Wassilew, Georgi I. [1 ]
Heller, Markus O. [2 ,3 ]
Hasart, Olaf [1 ]
Perka, Carsten [1 ]
Suedhoff, Ingrid [4 ]
Janz, Viktor [1 ]
Duda, Georg N. [2 ,3 ]
Koenig, Christian [2 ]
机构
[1] Charite, Ctr Musculoskeletal Surg, Dept Orthoped, D-10117 Berlin, Germany
[2] Charite, Ctr Sports Sci & Sports Med Berlin CSSB, Ctr Musculoskeletal Surg, D-10117 Berlin, Germany
[3] Charite, Ctr Sports Sci & Sports Med Berlin CSSB, Julius Wolff Inst, D-10117 Berlin, Germany
[4] Aesculap AG, Tuttlingen, Germany
关键词
Ultrasound; Computer navigation; Acetabular component; Cadaver; Accuracy; TOTAL HIP-ARTHROPLASTY; CUP PLACEMENT; PELVIC PLANE; REPLACEMENT; ORIENTATION; DISLOCATION; ACCURACY; POSITION; ANTEVERSION; MOTION;
D O I
10.1007/s00402-011-1412-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction This feasibility study investigated the accuracy of anterior pelvic reference plane (APP) registration and acetabular cup orientation in two cadavers with different BMIs. Method Five observers each registered the APP five times in the 2 cadavers (BMIs: 32 kg/m(2) and 25 kg/m(2)) using an ultrasound-based navigation system. By comparison against the CT-derived reference landmarks, the errors in determining the individual landmarks defining the APP, as well as the resulting errors in the orientation of the APP and the acetabular cup orientation were determined. Results Across all measurements obtained with the ultrasound navigation system, the errors in rotation and version in determining the APP were 0.5 degrees +/- 1.0 degrees and -0.4 degrees +/- 2.0 degrees, respectively. The cup abduction and anteversion errors determined from all measurements of the five investigators for both cadavers together were -0.1 degrees +/- 1.0 degrees and -0.4 degrees +/- 2.7 degrees, respectively. The data further demonstrated a high reproducibility of the measurements for the resulting cup adduction and anteversion angle. Conclusion Our preliminary results confirm that ultrasound navigation is a highly accurate tool that allows a reproducible registration of the APP and thereby enables accurate and precise intraoperative determination of the acetabular cup orientation also in patients with increased BMI.
引用
收藏
页码:517 / 525
页数:9
相关论文
共 50 条
  • [21] Ultrasound-based navigation of robotic drilling at the lateral skull base
    Federspil, PA
    Tretbar, SH
    Geisthoff, U
    Plinkert, B
    Plinkert, PK
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1358 - 1358
  • [22] Precision and bias of imageless computer navigation and surgeon estimates for acetabular component position
    Dorr, Lawrence A.
    Malik, Aamer
    Wan, Zhinian
    Long, William T.
    Harris, Michael
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (465) : 92 - 99
  • [23] Feasibility and accuracy of image guided liver resection using 3D ultrasound-based optoelectronic navigation
    Beller, S.
    Huenerbein, M.
    Lange, T.
    Eulenstein, S.
    Chopra, S.
    Schlag, P. M.
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2007, 2 : S280 - S282
  • [24] ULTRASOUND-BASED MEASUREMENT OF MOLECULAR MARKER CONCENTRATION IN LARGE BLOOD VESSELS: A FEASIBILITY STUDY
    Wang, Shiying
    Mauldin, F. William, Jr.
    Klibanov, Alexander L.
    Hossack, John A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (01): : 222 - 234
  • [25] Improved ultrasound-based navigation for robotic drilling at the lateral skull base
    Geisthoff, UW
    Tretbar, SH
    Federspil, PA
    Plinkert, PK
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 662 - 666
  • [26] Basic Study for Ultrasound-Based Navigation for Pedicle Screw Insertion Using Transmission and Backscattered Methods
    Chen, Ziqiang
    Wu, Bing
    Zhai, Xiao
    Bai, Yushu
    Zhu, Xiaodong
    Luo, Beier
    Chen, Xiao
    Li, Chao
    Yang, Mingyuan
    Xu, Kailiang
    Liu, Chengcheng
    Wang, Chuanfeng
    Zhao, Yingchuan
    Wei, Xianzhao
    Chen, Kai
    Yang, Wu
    Ta, Dean
    Li, Ming
    PLOS ONE, 2015, 10 (04):
  • [27] Ultrasound-based navigation system incorporating preoperative planning for liver surgery
    Eulenstein, S
    Lange, T
    Hünerbein, M
    Schlag, PM
    Lamecker, H
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 758 - 763
  • [28] Fusion imaging for intra-operative ultrasound-based navigation in neurosurgery
    Prada F.
    Del Bene M.
    Mattei L.
    Casali C.
    Filippini A.
    Legnani F.
    Mangraviti A.
    Saladino A.
    Perin A.
    Richetta C.
    Vetrano I.
    Moiraghi A.
    Saini M.
    DiMeco F.
    Journal of Ultrasound, 2014, 17 (3) : 243 - 251
  • [29] Acetabular component navigation in lateral decubitus based on EOS imaging: A preliminary study of 13 cases
    Billaud, A.
    Verdier, N.
    de Bartolo, R.
    Lavoinne, N.
    Chauveaux, D.
    Fabre, T.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (03) : 271 - 275
  • [30] A pilot feasibility study of an ultrasound-based tool to assess muscle mass in children with liver disease
    Shpoliansky, Michael
    Chavhan, Govind B. B.
    Zhou, Alex
    Ng, Vicky L. L.
    Kamath, Binita M. M.
    HEPATOLOGY COMMUNICATIONS, 2023, 7 (08)