Introduction: The purpose of this study was to investigate the clinical value of real-time three-dimensional transesophageal echocardiography (RT-3D-TEE) for percutaneous transcatheter closure of multiple secundum atrial septal defects (ASDs) using a Chinese domestic occluder device. Methods: From July 2008 to September 2011, 37 patients (mean age 28.4 +/- 9.7 years; 24 females) with multiple secundum ASDs underwent percutaneous transcatheter closure in our institution with custom-made occluder devices. RT-30-TEE was used to clarify the diagnosis and to help determine the operation scheme before the procedure, for real-time monitoring and guiding the operation during the procedure, and for evaluating the result shortly after the procedure. Results: The custom-made atrial septal occluders were successfully implanted in 36 patients under RT-3D-TEE guidance. Twenty-seven patients were implanted with two devices and 9 patients with a single device. In two patients where the distance between the two defects was less than 7 mm (5.5 mm and 6 mm), double occluder devices were also successfully implanted. One patient underwent surgery for the complication of unstable occluder and increased residual shunt after closure. No other severe complications were observed. Conclusions: RT-3D-TEE provides reliable diagnostic evidence of multiple ASDs and can help the clinician to select an appropriate operation scheme according to the number and morphology of multiple defects prior to percutaneous transcatheter closure. It also allows for proper positioning of the devices during the procedure and provides an effective means of evaluating the success of the procedure. For two devices to be implanted simultaneously in multiple ASDs, the usual requirement for the distance between the two defects may differ between our domestically made devices and the Amplatzer occluder.
引用
收藏
页码:486 / 491
页数:6
相关论文
共 50 条
  • [41] Role of Live/Real Time Three-Dimensional Transesophageal Echocardiography in the Percutaneous Epicardial Closure of the Left Atrial Appendage
    Joshi, Deepak
    Mazimba, Sula
    Kay, G. Neal
    Nanda, Navin C.
    Fan, Pohoey
    Schlotter, Florian
    Venkataraman, Rajesh
    Dumaswala, Bhavin
    Dumaswala, Komal
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2012, 29 (10): : 1256 - 1260
  • [42] Utility of On-Line Three-Dimensional Transesophageal Echocardiography During Percutaneous Atrial Septal Defect Closure
    Price, Matthew J.
    Smith, Michael R.
    Rubenson, David S.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (04) : 570 - 577
  • [43] Left atrial myxoma demonstrated by real-time three-dimensional transesophageal echocardiography
    Kaya, Hasan
    Gokdeniz, Tayyar
    Tuncer, Altug
    Ozkan, Mehmet
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2010, 38 (03): : 222 - 222
  • [44] Transesophageal echocardiography and fluoroscopy for percutaneous closure of atrial septal defects A comparative study
    Xu, Weize
    Li, Jianhua
    Ye, Jingjing
    Yu, Jin
    Yu, Jiangen
    Zhang, Zewei
    MEDICINE, 2018, 97 (43)
  • [45] Large atrial septal defect visualized by real-time three-dimensional echocardiography
    Watanabe N.
    Taniguchi M.
    Akagi T.
    Maruo T.
    Tanabe Y.
    Kasahara S.
    Kusano K.
    Koide N.
    Sano S.
    Journal of Echocardiography, 2009, 7 (2) : 39 - 40
  • [46] Quantitative analysis of the morphology of secundum-type atrial septal defects and their dynamic change using transesophageal three-dimensional echocardiography
    Franke, A
    Kuhl, HP
    Rulands, D
    Jansen, C
    Erena, C
    Grabitz, RG
    Dabritz, S
    Messmer, BJ
    Flachskampf, FA
    Hanrath, P
    CIRCULATION, 1997, 96 (09) : 323 - 327
  • [47] Evaluation and closure of periprosthetic leaks: role of real-time transesophageal three-dimensional echocardiography
    Mele, Donato
    Agricola, Eustachio
    Dal Monte, Alessandro
    Ancona, Marco Bruno
    Ferrari, Roberto
    GIORNALE ITALIANO DI CARDIOLOGIA, 2012, 13 (01) : 38 - 46
  • [48] Clinical usefulness of real-time three dimensional transesophageal echocardiography during transcatheter closure of atrial septal defect in the catheterization laboratory
    Taniguchi, M.
    Okamoto, Y.
    Akagi, T.
    Otsuki, S.
    Kusano, K.
    Ito, H.
    Sano, S.
    EUROPEAN HEART JOURNAL, 2010, 31 : 595 - 595
  • [49] En Face View of Atrial Septal Defect by Two-Dimensional Transthoracic Echocardiography: Comparison to Real-Time Three-Dimensional Transesophageal Echocardiography
    Huang, Xinsheng
    Shen, Junjun
    Huang, Yigao
    Zheng, Zhichao
    Fei, Hongwen
    Hou, Yueshuang
    Xu, Yan
    Huang, Tao
    Huang, Wenhui
    Zhang, Caojin
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (07) : 714 - 721
  • [50] Transcatheter closure of perimembranous ventricular septal defects with Amplatzer occluder assessed by real-time three-dimensional echocardiography
    Acar, Philippe
    Abadir, Sylvia
    Aggoun, Yacine
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2007, 8 (02): : 110 - 115