Real-Time Three-Dimensional Transesophageal Echocardiography Is Useful for Percutaneous Closure of Multiple Secundum Atrial Septal Defects

被引:0
|
作者
Zhang, Chun [1 ]
Li, Zhian [1 ]
Xu, Jin [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Dept Ultrasound, Beijing 100029, Peoples R China
关键词
Multiple atrial septal defects; transesophageal echocardiography; transcatheter closure; TRANSCATHETER CLOSURE; OCCLUDER; EXPERIENCE; IMMEDIATE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The purpose of this study was to investigate the clinical value of real-time three-dimensional transesophageal echocardiography (RT-3D-TEE) for percutaneous transcatheter closure of multiple secundum atrial septal defects (ASDs) using a Chinese domestic occluder device. Methods: From July 2008 to September 2011, 37 patients (mean age 28.4 +/- 9.7 years; 24 females) with multiple secundum ASDs underwent percutaneous transcatheter closure in our institution with custom-made occluder devices. RT-30-TEE was used to clarify the diagnosis and to help determine the operation scheme before the procedure, for real-time monitoring and guiding the operation during the procedure, and for evaluating the result shortly after the procedure. Results: The custom-made atrial septal occluders were successfully implanted in 36 patients under RT-3D-TEE guidance. Twenty-seven patients were implanted with two devices and 9 patients with a single device. In two patients where the distance between the two defects was less than 7 mm (5.5 mm and 6 mm), double occluder devices were also successfully implanted. One patient underwent surgery for the complication of unstable occluder and increased residual shunt after closure. No other severe complications were observed. Conclusions: RT-3D-TEE provides reliable diagnostic evidence of multiple ASDs and can help the clinician to select an appropriate operation scheme according to the number and morphology of multiple defects prior to percutaneous transcatheter closure. It also allows for proper positioning of the devices during the procedure and provides an effective means of evaluating the success of the procedure. For two devices to be implanted simultaneously in multiple ASDs, the usual requirement for the distance between the two defects may differ between our domestically made devices and the Amplatzer occluder.
引用
收藏
页码:486 / 491
页数:6
相关论文
共 50 条
  • [31] Is Three-Dimensional Echocardiography Useful in Evaluation of Atrial Septal Defects?
    German, Charles
    Nanda, Navin C.
    INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL, 2015, 9 (02) : 67 - 70
  • [32] Three-dimensional echocardiography in transcatheter closure of atrial septal defects
    Acar, P
    CARDIOLOGY IN THE YOUNG, 2000, 10 (05) : 484 - 492
  • [33] Application of Real-Time Three-Dimensional Transesophageal Echocardiography Using a Matrix Array Probe for Transcatheter Closure of Atrial Septal Defect
    Taniguchi, Manabu
    Akagi, Teiji
    Watanabe, Nobuhisa
    Okamoto, Yoshio
    Nakagawa, Koji
    Kijima, Yasufumi
    Toh, Norihisa
    Ohtsuki, Shinichi
    Kusano, Kengo
    Sano, Shunji
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (10) : 1114 - 1120
  • [34] Anatomic correlation of atrial septal defects by three-dimensional transesophageal echocardiography
    Roldan, F. J.
    Vargas-Barron, J.
    Antona, C. Vazquez
    Cardenas, A. Romero
    Castellanos, L. Munoz
    Orellana, J. Erdmenger
    EUROPEAN HEART JOURNAL, 2006, 27 : 796 - 796
  • [35] Percutaneous transcatheter closure of congenital heart septal defect with real-time three-dimensional echocardiography
    Chen, Guozhen
    Sun, Kun
    Gao, Wei
    Zhong, Yumin
    CARDIOLOGY, 2013, 126 : 86 - 86
  • [36] Percutaneous closure of secundum atrial septal defects
    Albers, Erin
    Janssen, Dana
    Ammons, Drew
    Doyle, Thomas
    PROGRESS IN PEDIATRIC CARDIOLOGY, 2012, 33 (02) : 115 - 123
  • [37] The role of transesophageal echocardiography in transcatheter closure of secundum atrial septal defects by the Amplatzer septal occluder
    Mazic, U
    Gavora, P
    Masura, J
    AMERICAN HEART JOURNAL, 2001, 142 (03) : 482 - 488
  • [38] Three-dimensional transesophageal echocardiography in percutaneous left atrial appendage closure
    Sampaio, Francisco
    Santos, Lino
    Rodrigues, Alberto
    Braga, Pedro
    Ribeiro, Jose
    Goncalves, Manuel
    Fonseca, Conceicao
    Gama, Vasco
    REVISTA PORTUGUESA DE CARDIOLOGIA, 2011, 30 (06) : 627 - 631
  • [39] Cor triatriatum dexter with atrial septal defect evaluated by real-time three-dimensional transesophageal echocardiography
    Yamaguchi R.
    Ota T.
    Tanigawa T.
    Sakai M.
    Norioka N.
    Ishikawa S.
    Kawai K.
    Nishiyama H.
    Tsumori T.
    Kamimori K.
    Yanagi S.
    Journal of Echocardiography, 2013, 11 (2) : 77 - 79
  • [40] Perioperative Assessment and Clinical Outcomes of Percutaneous Atrial Septal Defect Closure with Three-Dimensional Transesophageal Echocardiography
    Sarac, Ibrahim
    Birdal, Oguzhan
    DIAGNOSTICS, 2024, 14 (16)