Real-Time Three-Dimensional Transesophageal Echocardiography Is Useful for Percutaneous Closure of Multiple Secundum Atrial Septal Defects

被引:0
|
作者
Zhang, Chun [1 ]
Li, Zhian [1 ]
Xu, Jin [1 ]
机构
[1] Capital Med Univ, Beijing Anzhen Hosp, Dept Ultrasound, Beijing 100029, Peoples R China
关键词
Multiple atrial septal defects; transesophageal echocardiography; transcatheter closure; TRANSCATHETER CLOSURE; OCCLUDER; EXPERIENCE; IMMEDIATE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: The purpose of this study was to investigate the clinical value of real-time three-dimensional transesophageal echocardiography (RT-3D-TEE) for percutaneous transcatheter closure of multiple secundum atrial septal defects (ASDs) using a Chinese domestic occluder device. Methods: From July 2008 to September 2011, 37 patients (mean age 28.4 +/- 9.7 years; 24 females) with multiple secundum ASDs underwent percutaneous transcatheter closure in our institution with custom-made occluder devices. RT-30-TEE was used to clarify the diagnosis and to help determine the operation scheme before the procedure, for real-time monitoring and guiding the operation during the procedure, and for evaluating the result shortly after the procedure. Results: The custom-made atrial septal occluders were successfully implanted in 36 patients under RT-3D-TEE guidance. Twenty-seven patients were implanted with two devices and 9 patients with a single device. In two patients where the distance between the two defects was less than 7 mm (5.5 mm and 6 mm), double occluder devices were also successfully implanted. One patient underwent surgery for the complication of unstable occluder and increased residual shunt after closure. No other severe complications were observed. Conclusions: RT-3D-TEE provides reliable diagnostic evidence of multiple ASDs and can help the clinician to select an appropriate operation scheme according to the number and morphology of multiple defects prior to percutaneous transcatheter closure. It also allows for proper positioning of the devices during the procedure and provides an effective means of evaluating the success of the procedure. For two devices to be implanted simultaneously in multiple ASDs, the usual requirement for the distance between the two defects may differ between our domestically made devices and the Amplatzer occluder.
引用
收藏
页码:486 / 491
页数:6
相关论文
共 50 条
  • [21] PERCUTANEOUS CLOSURE OF SECOND ATRIAL SEPTAL DEFECT GUIDED BY THREE-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    Demirkol, S.
    Barcin, C.
    Balta, S.
    Unlu, M.
    Arslan, Z.
    Kucuk, U.
    Yokusoglu, M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S88 - S88
  • [22] Torn Atrial Septum during Transcatheter Closure of Atrial Septal Defect Visualized by Real-Time Three-Dimensional Transesophageal Echocardiography
    Kijima, Yasufumi
    Taniguchi, Manabu
    Akagi, Teiji
    Nakagawa, Koji
    Kusano, Kengo
    Ito, Hiroshi
    Sano, Shunji
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (11) : 1222.e5 - 1222.e8
  • [23] Initial experience with real-time three-dimensional transesophageal echocardiography in patients undergoing transcatheter atrial septal defect closure
    Passeri, Jonathan J.
    Inglessis, Ignacio
    Palacios, Igor F.
    Picard, Michael H.
    CIRCULATION, 2007, 116 (16) : 401 - 401
  • [24] Real-time three-dimensional echocardiography is useful in the evaluation of patients with atrioventricular septal defects
    Hlavacek, AM
    Crawford, FA
    Chessa, KS
    Shirali, GS
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2006, 23 (03): : 225 - 231
  • [25] Partially unroofed coronary sinus diagnosed by real-time three-dimensional transesophageal echocardiography after operation of secundum atrial septal defect
    Hai-yan Chen
    Cui-zhen Pan
    Xian-hong Shu
    The International Journal of Cardiovascular Imaging, 2015, 31 : 45 - 46
  • [26] Partially unroofed coronary sinus diagnosed by real-time three-dimensional transesophageal echocardiography after operation of secundum atrial septal defect
    Chen, Hai-yan
    Pan, Cui-zhen
    Shu, Xian-hong
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (01): : 45 - 46
  • [27] Three-Dimensional Echocardiography Guided Closure of Complex Multiple Atrial Septal Defects
    Kijima, Yasufumi
    Akagi, Teiji
    Nakagawa, Koji
    Takaya, Yoichi
    Oe, Hiroki
    Ito, Hiroshi
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2014, 31 (10): : E304 - E306
  • [28] Assessment of Atrial Septal Defect Anatomy by Real-Time Three-dimensional Transesophageal Echocardiography and Residual Shunting After Transcatheter Atrial Septal Defect Closure
    Johri, Amer M.
    Palacios, Igor F.
    Cubeddu, Roberto J.
    Inglessis, Ignacio
    Passeri, Jonathan
    CIRCULATION, 2009, 120 (18) : S392 - S392
  • [29] Three-dimensional Transesophageal Echocardiography of Atrial Septal Defect Device Closure
    Roberson, David A.
    Cui, Vivian Wei
    CURRENT CARDIOLOGY REPORTS, 2014, 16 (02)
  • [30] Three-dimensional Transesophageal Echocardiography of Atrial Septal Defect Device Closure
    David A. Roberson
    Vivian Wei Cui
    Current Cardiology Reports, 2014, 16