Experimental evaluation of validity of simplified Monte Carlo method in proton dose calculations

被引:33
|
作者
Kohno, R
Takada, Y
Sakae, T
Terunuma, T
Matsumoto, K
Nohtomi, A
Matsuda, H
机构
[1] Univ Tsukuba, Inst Clin Med, Tsukuba, Ibaraki 3058575, Japan
[2] Univ Tsukuba, Proton Med Res Ctr, Tsukuba, Ibaraki 3058575, Japan
[3] Univ Tsukuba, Inst Appl Phys, Tsukuba, Ibaraki 3058573, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 10期
关键词
D O I
10.1088/0031-9155/48/10/303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
It is important for proton therapy to calculate dose distributions accurately in treatment planning. Dose calculations in the body for treatment planning are converted to dose distributions in water, and the converted calculations are then generally evaluated by the dose measurements in water. In this paper, proton dose calculations were realized for a phantom simulating a clinical heterogeneity. Both dose calculations in the phantom calculated by two dose calculation methods, the range-modulated pencil beam algorithm (RMPBA) and the simplified Monte Carlo (SMC) method, and dose calculations converted to dose distributions in water by the same two methods were verified experimentally through comparison with measured distributions, respectively. For the RMPBA, though the converted calculations in water agreed moderately well with the measured ones, the calculated results in the actual phantom produced large errors. This meant that dose calculations in treatment planning should be evaluated by the dose measurements not in water but in the body with heterogeneity. On the other hand, the results calculated in the phantom, even by the less rigorous SMC method, reproduced the experimental ones well. This finding showed that actual dose distributions in the body should be predicted by the SMC method.
引用
收藏
页码:1277 / 1288
页数:12
相关论文
共 50 条
  • [1] TOTAL MONTE CARLO EVALUATION FOR DOSE CALCULATIONS
    Sjostrand, H.
    Alhassan, E.
    Conroy, S.
    Duan, J.
    Hellesen, C.
    Pomp, S.
    Osterlund, M.
    Koning, A.
    Rochman, D.
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 312 - 315
  • [2] Monte Carlo modeling of proton therapy installations: a global experimental method to validate secondary neutron dose calculations
    Farah, J.
    Martinetti, F.
    Sayah, R.
    Lacoste, V.
    Donadille, L.
    Trompier, F.
    Nauraye, C.
    De Marzi, L.
    Vabre, I.
    Delacroix, S.
    Herault, J.
    Clairand, I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11): : 2747 - 2765
  • [3] Simplified Monte Carlo dose calculation for therapeutic proton beams
    Kohno, R
    Sakae, T
    Takada, Y
    Matsumoto, K
    Matsuda, H
    Nohtomi, A
    Terunuma, T
    Tsunashima, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2002, 41 (3A): : L294 - L297
  • [4] Monte Carlo dose calculations for spot scanned proton therapy
    Tourovsky, A
    Lomax, AJ
    Schneider, U
    Pedroni, E
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (05): : 971 - 981
  • [5] Automatic Monte Carlo Dose Calculations of Proton Treatment Plans
    Titt, U.
    Mirkovic, D.
    Liu, A.
    Mohan, R.
    MEDICAL PHYSICS, 2012, 39 (06) : 3805 - 3805
  • [6] Monte Carlo and analytical dose calculations for proton spot scanning
    Bues, M
    Ciangaru, G
    Smith, A
    MEDICAL PHYSICS, 2004, 31 (06) : 1902 - 1903
  • [7] A simplified methodology to produce Monte Carlo dose distributions in proton therapy
    Beltran, Chris
    Jia, Yingcui
    Slopsema, Roelf
    Yeung, Daniel
    Li, Zuofeng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (04): : 2 - 10
  • [8] A Method to Assess the Need for Clinical Monte Carlo Dose Calculations for Small Proton Therapy Fields
    Bueno, M.
    Schuemann, J.
    Duch, M.
    Paganetti, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3874 - 3874
  • [9] Experimental and Monte Carlo evaluation of Eclipse treatment planning system for lung dose calculations
    Mesbahi, Asghar
    Thwaites, David I.
    Reilly, Andrew J.
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2006, 11 (03) : 123 - 133
  • [10] A Monte Carlo evaluation of RapidArc dose calculations for oropharynx radiotherapy
    Gagne, I. M.
    Ansbacher, W.
    Zavgorodni, S.
    Popescu, C.
    Beckham, W. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (24): : 7167 - 7185