Experimental and Monte Carlo evaluation of Eclipse treatment planning system for lung dose calculations

被引:18
|
作者
Mesbahi, Asghar [1 ]
Thwaites, David I. [2 ]
Reilly, Andrew J. [2 ]
机构
[1] Tabriz Univ Med Sci, Med Sch, Med Phys Dept, Tabriz, Iran
[2] Western Gen Hosp, Oncol Phys Dept, Edinburgh, Midlothian, Scotland
关键词
radiotherapy treatment planning; Monte Carlo method; lung inhomogeneity; thorax phantom; electronic equilibrium;
D O I
10.1016/S1507-1367(06)71057-4
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background In this study the accuracy of a pencil beam based treatment planning system (TPS) was evaluated for lung dose calculations by comparison with measurement and the Monte Carlo (MC) method. Aim In the current study we assessed the performance of the Eclipse treatment planning system in the thorax region by ionization chamber measurements and Monte Carlo calculations. We examined two analytic methods: modified Batho (MB) and equivalent tissue-air ratio "ETAR" methods for thorax region irradiadons. For Monte Carlo calculations in the thorax phantom, we modelled a Varian Clinac 2100EX linac. After benchmarking our model with water phantom measurements we used this model for thorax phantom calculations. Materials/Methods 8 and 15MV photon beams of Varian 21EX linac were used for irradiations. Using MANP4C Monte Carlo code, the geometry of the linac head was simulated. After commissioning "MC" beam models, lung doses were calculated by the Monte Carlo (MC) method. Irradiation cases were: ( I) posterior fields of single lung with field sizes of 4x4 and 10x10cm(2) (2) lateral fields of thorax with 4x4 and 10x 10cm(2) field sizes. Results TPS calculations involving ETAR and MB methods were in close agreement with Monte Carlo results and measurements for a 10x10 cm(2) field size at both energies. For a field size of 4x4cm(2) the maximum differences in local dose between TPS calculations and measurement were +33% (MB) and +28% (ETAR). Also, they ignored lung dose reduction due to lateral electronic equilibrium for small field size. Similar results would be expected for other TPSs implementing these algorithms. MC calculations were in excellent agreement with measurement, showing local differences of no more than 2% for all measured points. Conclusions Our study findings showed great differences between both analytical methods and measurements for 4x4cm(2) field sizes for points in the lung. Our study recommends using the MC method for small-field lung dose calculations.
引用
收藏
页码:123 / 133
页数:11
相关论文
共 50 条
  • [1] Experimental and Monte Carlo evaluation of Eclipse treatment planning system for effects on dose distribution of the hip prostheses
    Catli, Serap
    Tanir, Gunes
    [J]. MEDICAL DOSIMETRY, 2013, 38 (03) : 332 - 336
  • [2] Evaluation of the Monte Carlo Dose Calculation Engine of Eclipse Treatment Planning System for Electron Beams
    Kamta, G. Lagmago
    Reniers, B.
    [J]. MEDICAL PHYSICS, 2008, 35 (06)
  • [3] Evaluation of the accuracy of the electron Monte Carlo algorithm in eclipse treatment planning system
    Ge, W.
    Wong, P.
    Kalach, N.
    Osterman, S.
    Stein, N.
    Berson, A.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2101 - 2101
  • [4] Dosemetric Uncertainties in the Electron Monte Carlo Dose Calculation Algorithm in the Eclipse Treatment Planning System
    Kendall, E.
    Ahmad, S.
    Ali, I.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E249 - E250
  • [5] Evaluation of the AAA Treatment Planning Algorithm for SBRT Lung Treatment: Comparison with Monte Carlo and Homogeneous Pencil Beam Dose Calculations
    Gete, Ermias
    Teke, Tony
    Kwa, William
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2012, 43 (01) : 26 - 33
  • [6] Comparison of physical and biological plan evaluation parameters of Monte Carlo and conventional dose calculations in lung cancer treatment planning
    Seuntjens, J
    Heath, E
    Stroian, G
    Al-Yahya, K
    Dai, J
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S19 - S19
  • [7] Commissioning of Electron Monte Carlo in Eclipse Treatment Planning System for TrueBeam
    Yang, X.
    Lasio, G.
    Zhou, J.
    Lin, M.
    Yi, B.
    Guerrero, M.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 362 - 362
  • [8] Application of Monte Carlo calculations for validation of a treatment planning system in high dose rate brachytherapy
    Naseri, Alireza
    Mesbahi, Asghar
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2009, 14 (06) : 200 - 204
  • [9] Comparison of treatment planning dose calculations with measurements and Monte Carlo calculations in a RANDO phantom
    Wyatt, M
    Corredor, C
    Tamimi, M
    Miller, LF
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 461 - 465
  • [10] Experimental evaluation of a GPU-based Monte Carlo dose calculation algorithm in the Monaco treatment planning system
    Paudel, Moti R.
    Kim, Anthony
    Sarfehnia, Arman
    Ahmad, Sayed B.
    Beachey, David J.
    Sahgal, Arjun
    Keller, Brian M.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 230 - 241