Application of Monte Carlo calculations for validation of a treatment planning system in high dose rate brachytherapy

被引:13
|
作者
Naseri, Alireza [1 ,2 ]
Mesbahi, Asghar [1 ,2 ]
机构
[1] Tabriz Univ Med Sci, IMAM Hosp, Radiat Therapy Dept, Tabriz, Iran
[2] Tabriz Univ Med Sci, Med Sch, Med Phys Dept, Tabriz, Iran
关键词
Brachytherapy; High dose rate;
D O I
10.1016/j.rpor.2009.12.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: The accuracy of treatment planning systems is of vital importance in treatment outcomes in brachytherapy. In the current study the accuracy of dose calculations of a high dose rate (HDR) brachytherapy treatment planning system (TPS) was validated using the Monte Carlo method. Materials and methods: Three Co-60 sources of the GZP6 afterloading brachytherapy system were modelled using MCNP4C Monte Carlo (MC) code. The dose distribution around all the sources was calculated by MC and a dedicated treatment planning system. The results of both methods were compared. Results: There was good agreement (<2%) between TPS and MC calculated dose distributions except at a point near the sources (<1 cm) and beyond the tip of the sources. Conclusions: Our study confirmed the accuracy of TPS calculated dose distributions for clinical use in HDR brachytherapy. (C) 2009 Wielkopolskie Centrum Onkologii. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.
引用
收藏
页码:200 / 204
页数:5
相关论文
共 50 条
  • [1] Sub-second high dose rate brachytherapy Monte Carlo dose calculations with bGPUMCD
    Hissoiny, Sami
    D'Amours, Michel
    Ozell, Benoit
    Despres, Philippe
    Beaulieu, Luc
    [J]. MEDICAL PHYSICS, 2012, 39 (07) : 4559 - 4567
  • [2] Fast Monte Carlo dose calculations for brachytherapy
    Rogers, DWO
    Yegin, G
    Taylor, RE
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S17 - S17
  • [3] PATIENT SPECIFIC MONTE CARLO DOSE CALCULATIONS OF HIGH-DOSE-RATE BRACHYTHERAPY OF PARTIAL BREAST IRRADIATION
    Terribilini, D.
    Isaak, B.
    Manser, P.
    Frei, D.
    Volken, W.
    Mini, R.
    Fix, M. K.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S517 - S517
  • [4] Monte Carlo dose calculations for high-dose-rate brachytherapy using GPU-accelerated processing
    Tian, Z.
    Zhang, M.
    Hrycushko, B.
    Albuquerque, K.
    Jiang, S. B.
    Jia, X.
    [J]. BRACHYTHERAPY, 2016, 15 (03) : 387 - 398
  • [5] Correlated sampling for accelerating CT-based Monte Carlo dose calculations for brachytherapy treatment planning
    Le, Y.
    Todor, D.
    Williamson, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2236 - 2236
  • [6] The Effects of Calcification Modeling for Monte Carlo Dose Calculations of Low Dose Rate Prostate Brachytherapy
    Sutherland, J.
    Miksys, N.
    Soubiran, P.
    Cygler, J.
    Thomson, R.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3505 - 3505
  • [7] Experimental and Monte Carlo evaluation of Eclipse treatment planning system for lung dose calculations
    Mesbahi, Asghar
    Thwaites, David I.
    Reilly, Andrew J.
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2006, 11 (03) : 123 - 133
  • [8] Accelerated Monte Carlo based dose calculations for brachytherapy planning using correlated sampling
    Hedtjärn, H
    Carlsson, GA
    Williamson, JF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (03): : 351 - 376
  • [9] A Monte Carlo study of verification imaging in high dose rate brachytherapy
    Sheikh-Bagheri, D
    Munro, P
    [J]. MEDICAL PHYSICS, 1998, 25 (04) : 404 - 414
  • [10] Monte Carlo dosimetry of high dose rate gynecologic interstitial brachytherapy
    Desbiens, Maxime
    D'Amours, Michel
    Afsharpour, Hossein
    Verhaegen, Frank
    Lavallee, Marie-Claude
    Thibault, Isabelle
    Vigneault, Eric
    Beaulieu, Luc
    [J]. RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 425 - 429