Application of Monte Carlo calculations for validation of a treatment planning system in high dose rate brachytherapy

被引:13
|
作者
Naseri, Alireza [1 ,2 ]
Mesbahi, Asghar [1 ,2 ]
机构
[1] Tabriz Univ Med Sci, IMAM Hosp, Radiat Therapy Dept, Tabriz, Iran
[2] Tabriz Univ Med Sci, Med Sch, Med Phys Dept, Tabriz, Iran
关键词
Brachytherapy; High dose rate;
D O I
10.1016/j.rpor.2009.12.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Aim: The accuracy of treatment planning systems is of vital importance in treatment outcomes in brachytherapy. In the current study the accuracy of dose calculations of a high dose rate (HDR) brachytherapy treatment planning system (TPS) was validated using the Monte Carlo method. Materials and methods: Three Co-60 sources of the GZP6 afterloading brachytherapy system were modelled using MCNP4C Monte Carlo (MC) code. The dose distribution around all the sources was calculated by MC and a dedicated treatment planning system. The results of both methods were compared. Results: There was good agreement (<2%) between TPS and MC calculated dose distributions except at a point near the sources (<1 cm) and beyond the tip of the sources. Conclusions: Our study confirmed the accuracy of TPS calculated dose distributions for clinical use in HDR brachytherapy. (C) 2009 Wielkopolskie Centrum Onkologii. Published by Elsevier Urban & Partner Sp. z.o.o. All rights reserved.
引用
收藏
页码:200 / 204
页数:5
相关论文
共 50 条
  • [41] Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy
    Campos, Luciana Tourinho
    Veloso de Almeida, Carlos Eduardo
    [J]. PLOS ONE, 2015, 10 (09):
  • [42] Dose rate table for a 32P intravascular brachytherapy source from Monte Carlo calculations
    Bohm, TD
    Mourtada, FA
    Das, RK
    [J]. MEDICAL PHYSICS, 2001, 28 (08) : 1770 - 1775
  • [43] Validation of linear energy transfer computed in a Monte Carlo dose engine of a commercial treatment planning system
    Wagenaar, Dirk
    Tran, Linh T.
    Meijers, Arturs
    Marmitt, Gabriel Guterres
    Souris, Kevin
    Bolst, David
    James, Benjamin
    Biasi, Giordano
    Povoli, Marco
    Kok, Angela
    Traneus, Erik
    van Goethem, Marc-Jan
    Langendijk, Johannes A.
    Rosenfeld, Anatoly B.
    Both, Stefan
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (02):
  • [44] Dosimetric Evaluation of Treatment Planing System on High-Dose-Rate (HDR) Brachytherapy Using Monte Carlo Method and Radiochomic Film
    Pavan, G.
    Martins, M.
    Salmon, H.
    Anderson, E.
    Nardi, S.
    Fairbanks, L.
    Silva, D.
    Cursino, F.
    Junior, J.
    Silva, A.
    Santos, D.
    Werner, F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S743 - S743
  • [45] Application of the Inverse Monte Carlo Treatment Planning System IKO for an Inhomogeneous Dose Prescription in the Sense of Dose Painting
    Rickhey, Mark
    Bogner, Ludwig
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2006, 16 (04): : 307 - 312
  • [46] Commissioning validation of a brachytherapy treatment planning system with egsnrc monte carlo code and EBT3 GAFChromic film
    Lahlabou, Mohammed
    Khelifi, Rachid
    [J]. JOURNAL OF MEDICAL PHYSICS, 2022, 47 (04) : 352 - 361
  • [47] Monte Carlo characterization of 169Yb as a high-dose-rate source for brachytherapy application by FLUKA code
    Anjomrouz, Marzieh
    Sadeghi, Mahdi
    Haddadi, Asghar
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 196 - 205
  • [48] Dosimetric verification of a high dose rate brachytherapy treatment planning system in homogeneous and heterogeneous media
    Uniyal, S. C.
    Sharma, S. D.
    Naithani, U. C.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2013, 29 (02): : 171 - 177
  • [49] The impact of Monte Carlo dose calculations on treatment outcomes
    Keall, P
    Siebers, J
    Mohan, R
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 425 - 427
  • [50] Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source
    Daskalov, GM
    Loffler, E
    Williamson, JF
    [J]. MEDICAL PHYSICS, 1998, 25 (11) : 2200 - 2208