Simplified Monte Carlo dose calculation for therapeutic proton beams

被引:15
|
作者
Kohno, R
Sakae, T
Takada, Y
Matsumoto, K
Matsuda, H
Nohtomi, A
Terunuma, T
Tsunashima, Y
机构
[1] Univ Tsukuba, Inst Appl Phys, Tsukuba, Ibaraki 3058573, Japan
[2] Univ Tsukuba, Inst Clin Med, Tsukuba, Ibaraki 3058575, Japan
[3] Univ Tsukuba, Proton Med Res Ctr, Tsukuba, Ibaraki 3058575, Japan
来源
关键词
proton therapy; proton treatment planning; pencil beam algorithm; simplified Monte Carlo dose calculation; proton dose distribution; heterogeneity; edge-scattering;
D O I
10.1143/JJAP.41.L294
中图分类号
O59 [应用物理学];
学科分类号
摘要
A simplified Monte Carlo (SMC) method has been developed for dose calculation of therapeutic proton beams. It uses the depth-dose distribution in water measured by a broad proton beam to calculate the energy loss in a material easily and accurately. It employs the water-equivalent model of inhomogeneous materials. In addition, the multiple scattering effect in the materials is also calculated using the water-equivalent thickness. The accuracy of dose calculations by the SMC method is verified by comparison with dose measurements in a heterogeneous phantom. Results of the measured dose distributions agree well with calculations by the SMC method. though those determined by the dose calculation method based on the pencil beam algorithm show a large discrepancy. Therefore, the dose-calculation method by the SMC method will be useful for application to the treatment planning for proton therapy.
引用
收藏
页码:L294 / L297
页数:4
相关论文
共 50 条
  • [1] Macro Monte Carlo for dose calculation of proton beams
    Fix, Michael K.
    Frei, Daniel
    Volken, Werner
    Born, Ernst J.
    Aebersold, Daniel M.
    Manser, Peter
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (07): : 2027 - 2044
  • [2] Application of dose kernel calculation using a simplified Monte Carlo method to treatment plan for scanned proton beams
    Mizutani, Shohei
    Takada, Yoshihisa
    Kohno, Ryosuke
    Hotta, Kenji
    Tansho, Ryohei
    Akimoto, Tetsuo
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (02): : 315 - 327
  • [3] Fast Monte Carlo dose calculation in proton therapy
    Holmes, Jason
    Feng, Hongying
    Zhang, Lian
    Fix, Michael K.
    Jiang, Steve B.
    Liu, Wei
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (17):
  • [4] A Monte Carlo dose calculation algorithm for proton therapy
    Fippel, M
    Soukup, M
    [J]. MEDICAL PHYSICS, 2004, 31 (08) : 2263 - 2273
  • [5] Clinical implementation of proton Monte Carlo dose calculation
    Paganetti, H
    Jiang, H
    Kollipara, S
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2028 - 2028
  • [6] Monte Carlo Dose Calculation of Small Field Electron Beams
    Wu, Q.
    Rodrigues, A.
    Sawkey, D.
    Yin, F.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 307 - 307
  • [7] Accurate and efficient Monte Carlo dose calculation for electron beams
    Sheu, R.
    Chui, C.
    LoSasso, T.
    Lim, S.
    Kirov, A.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2067 - 2067
  • [8] Macro Monte Carlo for proton dose. Calculation in water
    Fix, M. K.
    Frei, D.
    Volken, W.
    Born, E. J.
    Aebersold, D. M.
    Manser, P.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2012, 188 (08) : 733 - 733
  • [9] Fast Monte Carlo Dose Calculation on GPU for Proton Therapy
    Jia, X.
    Schuemann, J.
    Paganetti, H.
    Jiang, S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S841 - S841
  • [10] Macro Monte Carlo for Proton Dose Calculation in Different Materials
    Fix, M. K.
    Frei, D.
    Volken, W.
    Born, E. J.
    Aebersold, D.
    Manser, P.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3873 - 3873