Intrinsic mechanical properties of trabecular calcaneus determined by finite-element models using 3D synchrotron microtomography

被引:14
|
作者
Follet, H.
Peyrin, F.
Vidal-Salle, E.
Bonnassie, A.
Rumelhart, C.
Meunier, P. J.
机构
[1] INSA, CNRS, UMR 5514, LaMCoS, Lyon, France
[2] INSA, CNRS, UMR 5515, CREATIS, Lyon, France
[3] INSERM, U403, Lab Histodynam Osseuse, F-69008 Lyon, France
关键词
microcomputed tomography (mu CT); finite-element models; biomechanical strength; trabecular bone; calcaneus;
D O I
10.1016/j.jbiomech.2006.10.032
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To determine intrinsic mechanical properties (elastic and failure) of trabecular calcaneus bone, chosen as a good predictor of hip fracture, we looked for the influence of image's size on a numerical simulation. One cubic sample of cancellous bone (9 x 9 x 9 mm(3)) was removed from the body of the calcaneus (6 females, 6 males, 79 +/- 9yr). These samples were tested under compressive loading. Before compressive testing, these samples were imaged at 10.13 mu m resolution using a 3D microcomputed tomography (mu CT) (ESRF, France). The mu CT images were converted to finite-element models. Depending on the bone density values (BV/TV), we compared two different finite element models: a linear hexahedral and a linear beam finite element models. Apparent experimental Young's modulus (E-app(exp)) and maximum apparent experimental compressive stress (sigma(exp)(max)) were significantly correlated with bone density obtained by Archimedes's test (E-app(exp) = 236 +/- 231 MPa [19-742 MPa], sigma(exp)(max) = 2.61 +/- 1.97 MPa [0.28-5.81 MPa], r > 0.80, p < 0.001). Under threshold at 40 pm, the size of the numerical samples (5.18 3 and 6.6 83 MM3) seems to be an important parameter on the accuracy of the results. The numerical trabecular Young's modulus was widely higher (E-trabecular(num) = 34,182 +/- 22,830 MPa [9700-87,211 MPa]) for the larger numerical samples and high BV/TV than those found classically by other techniques (4700-15,000 MPa). For rod-like bone samples (BV/TV < 12%, n = 7), Young's modulus, using linear beam element (E-trabecular(num-skeleton): 10,305 +/- 5500 Mpa) were closer to the youns's modulus found by other techniques. Those results show the limitation of hexahedral finite elements at 40 mu n, mostly used, for thin trabecular structures. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2174 / 2183
页数:10
相关论文
共 50 条
  • [1] Accuracy of 3D MR microscopy for trabecular bone assessment: a comparative study on calcaneus samples using 3D synchrotron radiation microtomography
    David Last
    Françoise Peyrin
    Geneviève Guillot
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2005, 18 : 26 - 34
  • [2] Accuracy of 3D MR microscopy for trabecular bone assessment: a comparative study on calcaneus samples using 3D synchrotron radiation microtomography
    Last, D
    Peyrin, F
    Guillot, G
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2005, 18 (01) : 26 - 34
  • [3] Accuracy of 3D MR microscopy for trabecular bone assessment: a comparative study on calcaneus samples using 3D synchrotron radiation microtomography
    David Last
    Françoise Peyrin
    Geneviève Guillot
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2005, 18 (1) : 57 - 57
  • [4] 3D histomorphometric quantification of trabecular bones by computed microtomography using synchrotron radiation
    Nogueira, L. P.
    Braz, D.
    Barroso, R. C.
    Oliveira, L. F.
    Pinheiro, C. J. G.
    Dreossi, D.
    Tromba, G.
    MICRON, 2010, 41 (08) : 990 - 996
  • [5] MECHANICAL-PROPERTIES OF TRABECULAR BONE, AN EXPERIMENTAL AND FINITE-ELEMENT STUDY
    HUISKES, R
    FAVENESI, J
    GARDENIERS, J
    POTTGENS, M
    SLOOFF, TJ
    JOURNAL OF BIOMECHANICS, 1985, 18 (07) : 522 - 522
  • [6] GEOMETRIC AND MECHANICAL 3D MODELING OF THE THORACIC SPINE USING THE FINITE-ELEMENT METHOD
    KOUBAA, W
    DEFIVES, T
    SKALLI, W
    LAVASTE, F
    ARCHIVES OF PHYSIOLOGY AND BIOCHEMISTRY, 1995, 103 (03) : C26 - C26
  • [7] VOLTAGE FORCED COILS FOR 3D FINITE-ELEMENT ELECTROMAGNETIC MODELS
    LEONARD, PJ
    RODGER, D
    IEEE TRANSACTIONS ON MAGNETICS, 1988, 24 (06) : 2579 - 2581
  • [8] Prediction of mechanical properties of vertebral trabecular bone using microstructural finite element models
    Dai, Yifei
    Ryan, Jordan
    Niebur, Glen L.
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 869 - 870
  • [9] Comparison of HR-pQCT- and microCT-based finite element models for the estimation of the mechanical properties of the calcaneus trabecular bone
    J. Alsayednoor
    L. Metcalf
    J. Rochester
    E. Dall’Ara
    E. McCloskey
    D. Lacroix
    Biomechanics and Modeling in Mechanobiology, 2018, 17 : 1715 - 1730
  • [10] Comparison of HR-pQCT- and microCT-based finite element models for the estimation of the mechanical properties of the calcaneus trabecular bone
    Alsayednoor, J.
    Metcalf, L.
    Rochester, J.
    Dall'Ara, E.
    McCloskey, E.
    Lacroix, D.
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2018, 17 (06) : 1715 - 1730